--- title: Canton Zoning Ordinance, 111.03.12. Generator transfer switch collection: local-codes id: local-code:canton/zoning/111.03.12 cite_as: Canton, Ga., Zoning Ordinance § 111.03.12 canonical_url: https://georgiacommons.org/code/local/canton/zoning/111.03.12 md_url: https://georgiacommons.org/code/local/canton/zoning/111.03.12.md text_url: https://georgiacommons.org/code/local/canton/zoning/111.03.12/text source_url: https://library.municode.com/ga/canton date: 2026-11-11 status: active jurisdiction: city:canton jurisdiction_name: Canton place_fips: "1312988" corpus_version: local-codes-canton-bb716bdc4821 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/canton/zoning/~part-iii/~chapter-111.md previous: https://georgiacommons.org/code/local/canton/zoning/111.03.11.md next: https://georgiacommons.org/code/local/canton/zoning/111.04.01.md index: https://georgiacommons.org/code/local/canton.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:canton/zoning/111.03.12@2026-11-11-736b6ee096 --- # Canton Zoning Ordinance, 111.03.12. Generator transfer switch > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part III - DEVELOPMENT CODE / Chapter 111 - DESIGN STANDARDS: SEWER SYSTEM TABLE OF CONTENTS A. The automatic transfer switch shall be manufactured by Kohler, ASCO, Zenith or alternate acceptable to the city. B. The transfer switch shall be rated for total normal and emergency system transfer for use on a 480 or 230 VAC, 3 phase, four-wire system. C. Each automatic transfer switch shall consist of a power transfer module and a control module, interconnected to provide complete automatic operation. The automatic transfer switch shall be mechanically held and electrically operated by a single-solenoid mechanism energized from the source to which the load is to be transferred. The switch shall be rated for continuous duty and be inherently double throw. The switch shall be mechanically interlocked to ensure only one of two possible positions, normal and emergency. D. The automatic transfer switch shall conform to the requirements of NEMA Standard ICS-2-447 and Underwriters' Laboratories UL-1008. E. The following time delays shall be provided: 1) A time delay to override momentary normal source outages. The time delay shall be field adjustable from one-half to six seconds and factory set at one second. 2) A time delay on retransfer to normal source. The time delay shall be automatically bypassed if the emergency source fails and normal source is available. The time delay shall be field adjustable from zero to 30 minutes and factory set at five minutes. 3) An unloaded running time delay for emergency generator cool down. The time delay shall be field adjustable from zero to five minutes and factory set at five minutes. 4) A time delay on transfer to emergency. The time delay shall be field adjustable from zero to five minutes for controlled timing of load transfer to emergency, and factory set at zero. F. The following features and accessories shall be provided: 1) Independent single phase voltage and frequency sensing of emergency source. The pickup voltage shall be adjustable from 85 percent to 100 percent of nominal. Pickup frequency shall be adjustable from 90 percent to 100 percent of nominal. Transfer to emergency upon normal source failure when emergency source voltage is 90 percent or more of nominal and frequency is 95 percent or more of nominal. 2) A contact that closes when normal source fails and one that opens when normal source fails, rated ten amps, 120 volts AC. 3) A white signal light to indicate when the automatic transfer switch is connected to the normal source. A yellow signal light to indicate when the automatic transfer switch is connected to the emergency source. 4) Two auxiliary contacts that are closed when the automatic transfer switch is connected to normal and two auxiliary contacts that are closed when the automatic transfer switch is connected to emergency. Rated ten amps, 120 volts, 60 Hz. AC. 5) A test switch to momentarily simulate normal source failure. 6) Reset switch to manually bypass time delay on retransfer to normal. 7) A permissive start/stop feature to provide for start/stop of the generator from a remote site regardless of the presence of normal utility power. G. The automatic transfer switch shall be mounted in a NEMA 4X for outdoor installations or a NEMA 1A for indoor non-ventilated installations. H. Copies of installation drawings and complete wiring diagrams and interconnections shall be furnished to the city. I. Each automatic transfer switch shall be furnished with three sets of the operator's manual providing installation and operating instructions. (Ord. No. 2014-18, § 2, 8-21-2014) 111.04.00 Wastewater treatment facilities.