Canton · Zoning Ordinance
Part III - DEVELOPMENT CODE / Chapter 114 / Article V - NON-DOMESTIC USE OF PUBLIC WASTEWATER FACILITIES / Division 1 - GENERALLY
Sec. 114-271. Sampling and testing procedures.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) Except as indicated in subsection (b) of this section, the user must collect wastewater samples using flow proportional composite collection techniques. In the event flow proportional sampling is infeasible, the city manager may authorize the use of time proportional sampling or a minimum of four grab samples where the user demonstrates that this will provide a representative sample of the effluent being discharged. In addition, grab samples may be required to show compliance with instantaneous discharge limits.
(b) Samples for oil and grease, temperature, pH, cyanide, phenols, hexavalent chromium, sulfides, and volatile organic compounds must be obtained using grab collection techniques.
History
(Ord. No. 2017-0921-01, § 1, 9-21-2017)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.