3.01.20. Standards for Areas of Shallow Flooding (AO Zones)
About this text
- As published by Municode, current through 2025-11-03
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Areas of Special Flood Hazard established in Section 3.01.06 may include designated "AO" shallow flooding areas. These areas have base flood depths of one to three feet above ground, with no clearly defined channel. The following provisions apply:
A. All new construction and substantial improvements of residential and non-residential structures shall have the lowest floor, including basement, elevated to the flood depth number specified on the Flood Insurance Rate Map (FIRM), above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least three feet above the highest adjacent grade.
Openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of Section 3.01.16(D) "Elevated Buildings."
The Floodplain Coordinator shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file.
B. New construction or the substantial improvement of a non-residential structure may be flood-proofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be water tight to the specified FIRM flood level plus two feet, above highest adjacent grade, with walls substantially impermeable to
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.