--- title: Carrollton Zoning Ordinance, Article 4 (Appendix B, no. 8 so numbered). DESIGN STANDARDS collection: local-codes id: local-code:carrollton/zoning/appendix-b-article-4-article-4-8 cite_as: Carrollton, Ga., Zoning Ordinance, Appendix B, Article 4 (no. 8 so numbered) canonical_url: https://georgiacommons.org/code/local/carrollton/zoning/appendix-b-article-4-article-4-8 md_url: https://georgiacommons.org/code/local/carrollton/zoning/appendix-b-article-4-article-4-8.md text_url: https://georgiacommons.org/code/local/carrollton/zoning/appendix-b-article-4-article-4-8/text source_url: https://library.municode.com/ga/carrollton/codes/code_of_ordinances date: 2025-11-03 status: active jurisdiction: city:carrollton jurisdiction_name: Carrollton place_fips: "1313492" corpus_version: local-codes-carrollton-66c7c129f650 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/carrollton/zoning/~appendix-b/~article-4.md previous: https://georgiacommons.org/code/local/carrollton/zoning/appendix-b-article-4-article-4-7.md next: https://georgiacommons.org/code/local/carrollton/zoning/4.02.01.md index: https://georgiacommons.org/code/local/carrollton.md branch: zoning edition: As published by Municode, current through 2025-11-03 edition_date_kind: current_through source_publisher: Municode version_id: local-code:carrollton/zoning/appendix-b-article-4-article-4-8@2025-11-03-dff796ee34 --- # Carrollton Zoning Ordinance, Article 4 (Appendix B, no. 8 so numbered). DESIGN STANDARDS > As published by Municode, current through 2025-11-03 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix B - ZONING (RESERVED) / Article 4 - DESIGN STANDARDS UDO4:7 Supp. No. 12 h. Pedestrian Entry. Each unit shall provide a clearly defined pedestrian entry utilizing the following standards. i. Each unit shall feature a main entry which includes architectural features that provide weather protection and visual interest to the structure. ii. The main entry to units adjacent to streets shall provide direct access to sidewalk system. i. Orientation. All homes shall be situated on the lot so that the conventional front of the home faces the front yard. j. Minimum Floor Area. The minimum floor area shall be nine hundred (900) square feet of heated space. k. Minimum Building Width. The minimum building width shall be sixteen (16) feet. l. Foundation. The dwelling shall be attached to a permanent foundation system, including the supporting, blocking, leveling, securing, and anchoring the home and connecting multiple and expandable sections of the home. The area beneath the home shall be enclosed by brick, concrete, wood, rock, or other materials specifically manufactured for this purpose and shall enclose the space between the floor joists and the ground level, except for the required minimum ventilation and access. Said access shall remain closed when not being used for that purpose. m. Connection to Carrollton GreenBelt. All townhouse developments within one thousand (1,000) feet of the Carrollton GreenBelt shall connect to the Carrollton GreenBelt with a path of the same dimensions, materials, and specifications as the Carrollton GreenBelt. The City Manager, at his sole discretion, is authorized to waive this requirement if topographic, property ownership, or other design or safety considerations prevent the construction of the path. n. Amenities. Common outdoor recreation space shall be provided in the form of trails, pavilions, multi purpose fields, playgrounds, community gardens, or another use consistent with the surrounding neighborhood. C. Additional standards for single-family dwellings to ensure appearance consistent with the surrounding neighborhood are required as follows: 1. Front and side yards shall be landscaped in accordance with Section 4.07.00 of the Unified Development Ordinance. 2. Vehicles may only be parked on paved areas designed for that purpose. 3. Architectural Standards for the Structures: a. Architectural Elements. The facades for each dwelling unit shall incorporate three (3) of the following architectural elements: i. Decorative window lintels. ii. Minimum of two (2) porch columns. iii. Decorative brackets. iv. Bay, bow, or garden windows. v. Dormers. vi. Any other architectural element city staff determines accomplishes intent. b. Exterior Siding shall consist of wood, masonry, rock, or fiber cement board. Vinyl siding is not permitted except on the cornices and soffits of the structures. Traditional style homes shall have a minimum of twenty (20) percent of the front of each home consisting of brick, stone, stucco, or other masonry; Farmhouse style homes shall contain siding types such as lap, board & batten or shakes. c. Porches. Each dwelling unit shall have at least one porch, patio or deck facing the street. Such shall be at least six (6) feet in depth and not less than forty (40) square feet. A three (3) foot by three (3) foot landing permanently affixed to the ground shall be provided at each exterior door. d. Windows. Walls facing the street other than an alley shall contain twenty (20) percent in doors and windows. Garage doors may be utilized in this calculation if they have architectural or carriage style features and contain windows. Windows shall be provided with trim. e. Roofs. Roof materials shall be wood shakes, metal, clay tile, fiberglass tile, slate, or architectural shingles. The minimum roof pitch shall be 5:12 or greater on all main roof areas and any gables facing the street shall have a minimum pitch of 7:12. Roofs shall utilize vertical or horizontal changes in rooflines, varied roof forms, and/or dormers. f. Garage doors shall not occupy more than 40-percent of the total building frontage. This measurement does not apply to garages facing an alley. g. Orientation. All homes shall be situated on the lot so that the conventional front of the home faces the front yard. h. Minimum Floor Area. The minimum floor area shall be nine hundred (900) square feet of heated space. i. Minimum Building Width. The minimum building width shall be sixteen (16) feet. j. Foundation. The dwelling shall be attached to a permanent foundation system, including the supporting, blocking, leveling, securing, and anchoring the home and connecting multiple and expandable sections of the home. The area beneath the home shall be enclosed by brick, concrete, wood, rock, or other materials specifically manufactured for this purpose and shall enclose the space between the floor joists and the ground level, except for the required minimum ventilation and access. Said access shall remain closed when not being used for that purpose. k. For manufactured homes, all tongues, wheels, axles, transporting lights, and other towing apparatus shall be removed from the site prior to occupancy. D. Variations. A variance from the design standards set forth in Section 4.02.01 can be requested from the Board of Development Appeals following the procedures and requirements set forth in Section 9.02.00 of this Unified Development Ordinance. (Res. No. 06-2017, 5-1-17; Res. No. 01-2018, 2-2-18; Res. No. 03-2019, 1-7-19; Res. No. 04-2019, 1-7-19; Res. No. 13-2024, 12-2-24)