4.02.02 Design Standards for Non-Residential and Mixed Use Development within C-1, C-2, C-3, R-O-I, and O-I. d. Buildings shall incorporate lighting and changes in mass, surface and finish giving emphasis to entrances. 3. Building materials. Permitted materials for building facades include, without limitation, brick, natural decay resistant wood siding, rock, stone, decorative concrete block or concrete walls with textured surface materials, and hardi-board. Facade colors shall be earthtone or neutral. Building trim and accents may feature brighter colors, not to exceed twenty-five (25) percent of any building facade. Vinyl lap siding may not be used. 4. Roofs. a. Roofs shall at a minimum have parapets concealing flat roofs and rooftop equipment which are visible from adjoining streets or properties. b. On buildings greater than 50,000 square feet, parapets and facades shall be designed to give the appearance of three or more roof slope planes. 5. Maximum square footage. No single retail space shall exceed 150,000 gross square feet. 6. Minimum residential unit size. In mixed use buildings, residential units shall be a minimum of 800 square feet. B. Site Design Standards. 1. Landscaping. a. A landscape strip at least ten (10) feet wide shall be provided between the right-of-way and any buildings, plazas, or parking areas. Properties located within the C-1 zoning district are exempt from this provision. b. Streetscape trees shall be provided in accordance with Section 4.07.00 along public right-of-way adjacent to the property. c. On buildings larger than 50,000 square feet, a minimum of seven (7) percent of the total parking area shall be located within the parking area in the form of landscape islands and peninsulas. d. Landscaping and buffering shall be completed in accordance with Section 4.07.00. 2. Pedestrian Circulation. a. In order to encourage pedestrian-oriented developments, buildings sited within 40 feet of the street shall provide primary public access from the public sidewalk along the street. b. Sidewalks, no less than six (6) feet in width shall be provided along all sides of the lot that abuts a street. c. Pedestrian connections shall be made from the sidewalk to the entrance of the building. d. A pedestrian circulation plan shall be provided in developments with a building greater than 50,000 square feet. 3. Parking. a. Location. Parking areas shall not be located between the building and the street within the C-1, C-3, and R-O-I zoning district. One parking isle is permitted between the building and the street in the C-2 and O-I zoning district. In the C-1 4.02.02 Design Standards for Non-Residential and Mixed Use Development within C-1, C-2, C-3, R-O-I, and O-I. UDO4:9 Supp. No. 7 zoning district, if adequate public parking is available within 200 feet of the project, Staff may waive parking requirements. In the C-1 zoning district, on-street parking shall be permitted in designated areas only. b. Parking lots with 50 or more spaces shall be divided into separate areas and divided by landscape areas or walkways at least ten (10) feet in width or by a building or groups of buildings. Parking lots shall be landscaped and buffered in accordance with Section 4.07.00. c. Bicycle parking facilities. Bicycle parking facilities shall be provided in parking lots greater than fifty (50) spaces serving buildings that are open to the public. d. Interparcel connectivity. An internal driveway accessing adjacent commercial properties, whether developed or undeveloped, shall be provided unless the City Manager determines the connection is not feasible given the topography. e. For buildings larger than 50,000 square feet, no more than seventy-five (75) percent of the total number of required parking spaces shall be located between the building and the street. 4. Solid Waste Storage Areas. Solid waste receptacles, shipping pallets, bundled cardboard and similar waste materials stored for collection shall be enclosed on all sides and screened from view from adjoining residential properties or streets with a solid enclosure (at least six feet high) with a gate and shall be constructed of wood, masonry, or other compatible material. The enclosure shall measure a minimum of 13 feet by 10 feet with an opening measuring no less than 13 feet. A ten (10) foot by twenty (20) foot concrete pad at least 6 inches thick shall be provided for the garbage truck loading/unloading area. 5. Outdoor Storage and Loading Areas. a. Areas for truck parking and loading shall be screened by a combination of structures and landscaping to minimize visibility from adjacent streets and property lines. If visible from adjacent property, screening structures shall be made of similar materials as the principal structure. b. Non-enclosed areas for the storage and sale of inventory shall be permanently defined and screened with walls and/or fences. Materials, colors, and design of the screening walls and/or fences shall conform to those used in the principal structure. If such areas are to be covered, then the covering shall conform to the exposed roofing colors of the buildings. 6. Community Spaces. For developments involving gross floor area in excess of 50,000 square feet, one square foot of plaza or community space shall be provided for every ten (10) square feet of gross floor area. Plazas and community spaces must incorporate three (3) of the following four (4) elements: a. Sitting spaces. At least one sitting space for each 250 square feet shall be included in the plaza. Ledge benches shall have a minimum depth of thirty-six (36) inches. b. Trees in accordance with the City of Carrollton Tree Species List at a minimum of one tree per 800 square feet. c. Water features or public art. d. Outdoor eating areas.