2. Radii or Flare: Minimum five (5) feet. 3. Spacing from Street Intersection: Minimum forty (40) feet. 4. Angle of intersection with roadway: Not less than seventy-five (75) degrees. 5. Max Grade: two percent (2%) across any sidewalk section then eight percent (8%) in the right-of-way when connecting to a collector or arterial street and fifteen percent (15%) within the right-of-way when connecting to a lower category street. 6. Length: A minimum of twenty-five (25) feet or to the edge of the right-of-way, whichever is greater, shall be paved with a treated hardened surface. 7. Access to all residential lots shall be from interior subdivision streets or roads where possible. Exceptions are subject to the approval of the City Engineer. 8. Where a residential driveway crosses a drainage swale, a driveway culvert shall be sized to handle the twenty-five (25) year storm event. Where the drainage swale is adjacent to an arterial or collector street, additional storm events, up to and including the 100-year storm event, may be required to be analyzed to prevent flooding of the street.