Skip to content
Georgia Commons
Menu

Carrollton · Zoning Ordinance

Appendix B - ZONING (RESERVED) / Article 6 - INFRASTRUCTURE IMPROVEMENTS

6.10.04. Access Easements

About this text

  • As published by Municode, current through 2025-11-03
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

E. Driveways servicing multi-family, commercial and office/industrial developments shall provide uninterrupted ingress/egress.

F. For purposes of sight distance, all driveways are to be considered low volume intersections and to comply with minimum intersection/corner sight distance requirements contained in this UDO.

G. To allow for proper corner clearance, the minimum tangent curb length between a driveway radius and an intersection shall be one hundred (100) feet.

H. Driveways are not to be installed closer than ten (10) feet to a catch basin, measured along the gutter line from the centerline of catch basin to the nearest edge of the driveway (extended). No catch basins will be allowed within driveway turning radii.

I. For all developments, roadway improvements to provide a separate left turn lane into the proposed development shall be considered on a case-by-case basis.

J. If the closest intersection is or is likely to be signalized, then traffic movements to and from any driveway within two hundred fifty (250) feet of an intersection with a collector or an arterial street shall be limited to right turns only.

K. Multifamily, commercial and office/industrial driveways are to be constructed to the following standards:

1. Width:

a. Minimum twelve (12) feet for one-way access;

b. Maximum eighteen (18) feet for one-way access;

c. Minimum Two (2) twelve (12) feet lanes for two-way access; and

d. Maximum Two (2) sixteen (16) feet lanes for two-way access (driveways with turn lanes, medians or other design alternatives are subject to the approval of the City Engineer).

2. Lanes shall be designated by striping and directional arrows.

3. Radii:

a. Minimum thirty (30) feet

b. Maximum fifty (50) feet

4. Angle of intersection: not less than seventy-five degrees (75°).

5. Grade: plus or minus two percent (2%) of the intersecting roadway within the right-of-way.

L. Design standards may be varied with the approval of the City Engineer to meet the design intent of special design districts.

6.11.00 DECELERATION LANES AND TURN LANES

6.11.01 Deceleration and Turning Lanes

A. A deceleration lane shall be required at each entrance to a residential subdivision of more than twenty-five (25) lots, at each entrance to a commercial or industrial subdivision, and at each entrance to a multi-family or non-residential development project at its point of access.

B. A left turning lane shall be required for each entrance to a subdivision or development project intersecting a major arterial street.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:carrollton/zoning/appendix-b-article-6-6.10.04-3@2025-11-03-90092f7a36

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Carrollton Zoning Ordinance, 6.10.04 (Appendix B, Article 6, no. 3 so numbered). Access Easements | Georgia Commons