6.07.00 STREETS

6.07.03 Relation to Present and Future Street System Table 6.07.04 (A): Minimum Right-of-Way Width Street Classification Width of Right-of-way Arterial Street 100 feet Collector Street* Residential (Single-family, Duplex)* Multifamily, commercial, industrial 60 feet 80 feet Local Commercial or Industrial Street 60 feet Local Residential Street 50 feet Alleys 20 feet *A Residential Collector is any street within a residential development that will have over 100 daily peak hour trips.

D. Additional right-of-way.

1. Subdivisions that include an existing street that does not conform to the minimum right-of-way requirements of this UDO shall provide additional width along one or both sides of such street or road so that the minimum right-of-way required by this UDO is established. Subdivisions abutting only one side of such a street or road shall provide a minimum of one-half of the right-of-way required by these regulations, measured from the center of the existing right-of-way.

2. When a future street or road, as proposed in the Comprehensive Plan, adjoins or traverses the subdivision or development project, the future right-of-way shall be platted as part of the subdivision or development project. No development will be allowed within the platted future right-of-way except for drives and landscaping, and the platted future right-of-way is to be treated as a lot line for the provision of all setback lines as required by this Article. The developer will be contractually bound to the City to sell this strip of land to the City at a future date, for the amount stated in the tax digest. A right-of-way agreement shall be executed before the City Engineer approves the development.

E. General design requirements.

a. General design requirements for streets, including street grades, minimum design speeds, vertical and horizontal alignment, and minimum sight distance, are located within the Design and Construction Standards on file in the office of the City Engineer.

F. Dead-end streets (cul-de-sacs).

1. A cul-de-sac street shall be no more than 600 feet long or serve more than 19 lots, whichever is greater, unless necessitated by topographic or other conditions and approved by the City Engineer. If these conditions exist, the maximum length shall be 800 feet unless a greater length is approved by the Carrollton Mayor and City Council through the Planned Development process.

2. Turn-around dimensions.

a. Cul-de-sacs in residential subdivisions shall terminate in a circular turn-around having a minimum right-of-way of at least 100 feet in diameter, and a paved turn-around with a minimum outside diameter of eighty (80) feet.

b. Cul-de-sacs in commercial and industrial subdivisions shall terminate in a circular turn-around having a minimum right-of-way of at least 160 feet in diameter, and a paved turn around with a minimum outside diameter of 120 feet.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:carrollton/zoning/appendix-b-article-6-article-6-12@2025-11-03-d9d7497531

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Carrollton Zoning Ordinance, Article 6 (Appendix B, no. 12 so numbered). INFRASTRUCTURE IMPROVEMENTS | Georgia Commons