As-builts shall be required before the final plat is recorded for subdivisions or before a certificate of occupancy issued for commercial/ industrial sites. All as-built drawings must be on standard twenty-four (24) inches × thirty-six (36) inches sheets with a maximum scale of one (1) inch = fifty (50) feet. Electronic files must also be submitted in AutoCAD format with water, sewer and storm system all on separate layers. (a) The water system as-builts shall show locations of fire hydrants, line valves, tees, water main sizes, and types of materials. (b) The sanitary sewer system as-builts shall show locations of manholes, lines, services, line sizes, types of materials, manhole inverts, and line grades. (c) Street ands storm sewer as-builts shall show street layout, profiles, grades, storm sewers and sizes, storm drainage structures, and detention ponds. (d) Commercial site layout as-builts in addition to water, sanitary sewer, and storm sewer, as-builts shall include, but not limited to, the following final locations of building(s), entrance(s), parking, and grading on computer disk in AutoCAD format (if feasible). (e) Sprinkler system as-builts with head count.