Cartersville · Zoning Ordinance
Part - CODE OF ORDINANCES / Chapter 7.5 - DEVELOPMENT REGULATIONS / Article IV - SEWER SPECIFICATIONS
Sec. 7.5-91. General information.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(1) Use of This document:
(a) This document is subject to periodic revision to meet changing requirements for materials, fire and safety regulations,
environmental regulations, etc. At the beginning of a project the user should verify that he has the latest edition.
(b) This document is intended to convey the general design and construction requirements for a typical project. It also lists specific City requirements relating to
plan review, inspection, testing and acceptance of facilities. It is not intended as a substitute for site-specific engineering and construction techniques.
(2) Connection to existing sewers:
(a) All future buildings within the City's corporate limits which are to be utilized for occupancy or any other use such as
commercial or industrial purposes which requires sanitary sewerage facilities shall be connected to the public sewer system
except as provided in sections 24-80, 24-81 of this Code. Cost of constructing the necessary facilities for connection to public sewers shall be at the expense of the developer.
(b) The City maintains the option of requiring developers of individual lots to construct main line extensions of up to
two hundred (200) feet to avoid cutting pavement on existing streets for connection to the public sewer.
(3) Definition of sewer line terminology:
(a) "Building sewers" or "service laterals" are defined as those pipes used to convey wastewater from the building or portions of a building to a main sewer. The
minimum diameter for a service lateral is six (6) inches. These sewers are privately funded and owned.
(b) "Main sewers" are located in streets, rights-of-way, or dedicated easements.
They are gravity piping systems used to collect sewage from one (1) or more service laterals to other main sewers. Main
sewers are a minimum of eight (8) inches in diameter and may extend beyond the
property boundaries of a development.
Funding of main sewers is by the developer.
(c) "Force main sewers" are pressure piping systems which convey sewage from a
pump station to a main sewer. These sewers are constructed of ductile iron pipe and have a minimum diameter of six (6) inches. Funding of force mains is by the developer.
(d) "Private sewerage systems" are all nonpublic sewer systems as approved by the water superintendent pursuant to chapter 24 of this Code.
(4) When public sewers are not available:
(a) If sewers are not adjacent to the property, the following options are available:
1. Provide a private sewerage system pursuant to section 24-80 and 24-31 of this Code.
2. Extend city sewers to the area.
(5) Location and site considerations:
(a) Karst topography: The City of Cartersville is located in an area where Karst topography has been identified. A letter from a professional geologist, registered in "the state of Georgia, will be required for new developments stating that the
proposed site is not located within Karst topography or that differential settling/ sewer collapse due to Karst topography
is unlikely to occur.
(b) Fault zones: Because a fault zone exists in Bartow County, it should be noted that sanitary sewer lines shall not be
constructed perpendicular to a fault zone whenever possible. If a sewer line needs to cross a fault line, specify the sewer to have flexible, compensating gaskets
installed as well as the line to be supported in a spring adjusting pipe cradle.
(c) Stream buffers: No sewers shall be installed within twenty-five (25) foot state water buffer or within fifty (50) feet of trout streams.
(d) Wetlands: The design professional whose seal appears on the drawings must certify that:
1. The National Wetlands Inventory maps have been consulted.
2. The appropriate plan sheet does/ does not indicate areas of the United States Army Corps of Engineers jurisdictional wetlands as shown on the maps. If jurisdictional wetlands are indicated, the landowner or developer must obtain a Federal Wetlands Alteration (Section 404) permit prior to land disturbance of the protected wetlands. There are permits that may need to be obtained before initiating construction activity. Provide specifications for the above requirements.
(e) Landfills: No sewers, services, or any other utilities are to be constructed on or serve structures, constructed or proposed, on solid waste landfills
(f) Proximity to water supplies: Should a sewer line be placed adjacent to a water reservoir, it shall be placed down gradi-ent (rather than up gradient) of the
reservoir embankment. DIP will be required for all such instances.
History
(Ord. No. 43-24, § 1, 10-3-24)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.