Catoosa County · Zoning Ordinance
Appendix A - CATOOSA COUNTY UNIFIED DEVELOPMENT CODE / Article III - NATURAL RESOURCE PROTECTION
3.05.03. Protection Criteria
About this text
- As published by Municode, current through 2023-09-19
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
The following regulations shall apply to the City of Ringgold Water Supply Watershed identified on the Water Supply Watershed Protection District Overlay Map as a small water supply watershed.
A. The corridors of all perennial streams within a seven mile radius upstream of a governmentally owned public drinking water supply intake or water supply reservoir must be protected by the following criteria:
1) A buffer shall be maintained for a distance of 100-feet on both sides of the stream as measured from the stream banks.
2) No impervious surface shall be constructed within a 150-foot setback area on both sides of the stream as measured from the stream banks.
3) Septic tanks and septic tank drainfields are prohibited in the 150-foot setback area as described in Section 3.05.03.A.(2).
B. The corridors of all perennial streams outside a seven mile radius upstream of a governmentally owned public drinking water supply intake or water supply reservoir must be protected by the following criteria:
1) A buffer shall be maintained for a distance of 50-feet on both sides of the stream as measured from the stream banks.
2) No impervious surface shall be constructed within a 75-foot setback area on both sides of the stream as measured from the stream banks.
3) Septic tanks and septic tank drainfields are prohibited in the 75-foot setback area as described in Section 3.05.03.A.(2).
C. The impervious surface area, including all public and private structures, utilities, or facilities, of the entire water supply watershed shall be limited to 25 percent, or existing use, whichever is greater.
D. New facilities which handle hazardous materials of the types listed in Section 312 of the Resource Conservation and Recovery Act of 1976 (excluding underground storage tanks) and amounts of 10,000 pounds or more on any one day, shall perform their operations on impervious surfaces and in conformance with any applicable federal spill prevention requirements or the requirements of the standard fire prevention code.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.