Skip to content
Georgia Commons
Menu

Chamblee · Zoning Ordinance

Appendix A - UNIFIED DEVELOPMENT ORDINANCE / Title 2 - LAND USE AND ZONING / Chapter 230 - STANDARDS APPLYING TO ALL DISTRICTS / Article 1 - ZONING PROVISIONS

Section 230-1. Dimensional standards of zoning districts.

About this text

  • As published by Municode, retrieved 2026-11-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
  • Tables are shown as their rows, with the cells separated by a bar ( | ).

(a) The following Space Dimensions Table states the space dimensions required for each lot in a zoning district:

Space Dimensions Table9, 10

| | | | | | | | | | | | | | | |----|----|----|----|----|----|----|----|----|----|----|----|----|----| | | NR-1 | NR-2 | NR-3 | VR | NC-11 | NC-21 | CC | CVC | VC | TOD | MU-BC | IT | I | | Total FAR (max.) | 0.50 | 0.50 | 1.0 | 2.0 | 1.0 | 2.0 | 2.5 | 2.5 | 4.0 | 6.0 | None | 1.0 | 1.0 | | Maximum Impervious Surface (% of lot area) 3 | 45% | 55% | 60% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | 80% | | Minimum Open Space (% of lot area) 2 | N/A | N/A | 10% | 10% | 10% | 10% | 10% | 10% | 10% | 10% | 10% | 10% | N/A | | Max building height 3, 8 | 34' | 34' | 38' | 48' | 48' | 60' | 60' | 60' | 75' | 90' | None | 60' | 60' | | Lot size (min. in square feet) | 8,000 sf | 6,000 sf | None | None | None | None | None | None | None | None | None | None | None | | Lot width (min. in feet) 4 | 55' | 45' | None | None | None | None | None | None | None | None | None | None | 100' | | Front yard setback (min. in feet) 5, 6 | 20' | 20' | 20' | 10' | None | None | None | None | None | None | None | None | 10' | | Street Side yard (min. in feet) 7 | 15' | 15' | 15' | 5' | None | None | None | None | None | None | None | None | None | | Side yard (min. in feet) | 7.5' | 5' | None | None | None | None | None | None | None | None | None | 10' | 10' | | Rear yard (min. in feet) | 25' | 20' | 20' | None | None | None | None | None | None | None | None | 20' | 20' |

1

Single-family detached residential developments in NC-1/NC-2 shall follow the dimension standards for NR-2.

2

See also open space provision in Section 230-30.

3

Additional height limitations are in place for any structure within the Runway Protection Zone, see Section 220-1. In addition, any construction within five miles of the DeKalb Peachtree Airport is subject to Title 14 of the Code of Federal Regulations (14 CFR) Part 77 and may require review by the Federal Aviation Administration.

4

Cul-de sac lots shall provide the minimum lot width at the front yard setback line. The lot width shall not be measured from the discretionary placement of the principal structure.

5

Front yard requirements for through lots. Buildings on through lots extending through from street to street shall provide the required front yard on all streets.

6

Detached houses constructed or renovated on a block face that is occupied by two or more detached houses shall comply with Section 230-3, Contextual Lot and Building Standards for Infill Development.

7

Side yard requirements are variable in the NR-3, VR, NC-1, NC-2, CC, CVC, VC, TOD and MU-BC, depending on the abutting zoning district; see Buffer Specifications Table below.

8

See Section 230-5 for height exceptions.

9

See Subsection 240-13(b)(1) for single-family attached (townhouse) dwelling dimensional standards.

10

Residential front yards.

a. In single-family residential districts, the front yard shall be landscaped with the exception of driveways, terraces, and walkways, which may occupy a maximum of one-half of the front yard area.

b. Automobile parking is only permitted in front yards when located on the permitted access driveway.

c. Access driveways shall be paved with the concrete, asphalt, or paver surface.

(b) Location and width of zoning buffers.

(1) The following Buffer Specification Table states the minimum buffer specifications required for each zoning district.

a. The required buffer strip shall be permitted to be included in the minimum yard area as specified in the appropriate zoning district in the Buffer Specification Table.

b. Zoning buffers shall be planted to planting standards in Section 320-21.

Buffer Specification Table

Table 1. This was a table in the source. Each line is one of its rows, with its cells in order, separated by a bar. A row may have fewer cells than the table has columns, so read the cells in order, not by column.
  1. Proposed Use
  2. Contiguous Zoning District or Existing Land Use | Single-family detached use | Single-family attached use | All other uses | Industrial uses (I, IT)
  3. NR-1 or NR-2 Zoning District | None | 30 feet | 40 feet | 50 feet
  4. Single-family residential uses in NC-1 and NC-2 | None | None | None | 50 feet
  5. Single-family residential uses in all other zoning districts | None | None | 30 feet | 50 feet
  6. Multifamily uses | None | None | 20 feet | 40 feet

History

The history line the source prints at the end of the section.

(Ord. No. 743, 12-19-17; Ord. No. 748, 3-20-18; Ord. No. 757, 12-18-18; Ord. No. 776, 12-17-19; Ord. No. 784, 8-18-20; Ord. No. 805, 12-21-21)

Meetings that refer to this section

Found 1: meetings of this government whose minutes or machine transcripts name this section, or an ordinance in its history line, newest first. Found by rule from those records' own words. A reference is a pointer to another record, not a statement that the section applies or was changed.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:chamblee/zoning/230-1@2026-11-14-07790af274

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Chamblee Zoning Ordinance, Section 230-1. Dimensional standards of zoning districts | Georgia Commons