Section 230-27. Building architecture.
About this text
- As published by Municode, retrieved 2026-11-14
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) All buildings except for single-family residential.
(1) Exterior building materials, that face the public right-of-way or are visible from adjacent properties, excluding architectural accents or metal split seam roofing, shall be primarily brick, glass, wood, stucco, or stone. Other materials not listed may be considered but shall be reviewed and considered by the Planning and Development Director.
(2) Textured concrete masonry, cementitious fiberboard, or EFIS siding may be used as an exterior building materials, but shall not constitute the majority of any side of a building.
(3) Cementitious fiberboard lap siding shall only be permitted on buildings less than 3 stories.
(4) Masonry shall wrap corners to avoid appearance of being applied.
(5) A maximum of 40 percent of a building facade is permitted to be clad with metal. Acceptable metal materials are limited to architectural metal panels, architectural metal cladding, metal mesh, and perforated metal. Standing seam metal roofing is permitted for the entirety of the roof surface. Examples of materials not permitted include but are not limited to: stock PEMB metal skins commonly referred to as "R-panel" and sheet metal systems with exposed fasteners, except as required for perforated metal.
(6) Fenestration shall be provided for a minimum of 60 percent for commercial uses and 40 percent for all other applicable uses along the length of all building facades fronting storefront streets. Fenestration shall be provided for a minimum of 50 percent for commercial uses and 30 percent for all other applicable uses along the length of all building facades fronting all other street types. Fenestration percentages shall be measured according to the following:
a. If the finished floor elevation is between zero and three feet above the sidewalk, fenestration requirements shall apply between a horizontal line no more than three feet above the sidewalk and a horizontal line no less than ten feet above the sidewalk;
b. If the finished floor elevation is more than three feet above the sidewalk, fenestration requirements shall apply between the finished floor elevation and a horizontal line no less than ten feet above the finished floor elevation; or
c. If the finished floor elevation is below the sidewalk, fenestration requirements shall apply between a horizontal line no higher than sidewalk level and a horizontal line no less than ten feet above the finished floor elevation;
d. The length of facade without intervening fenestration or entryway shall not exceed 20 linear feet;
e. Fenestration shall not utilize painted glass, reflective glass or other similarly treated or opaque windows. Entrances may be counted towards fenestration requirements.
(7) When located on a lot with multiple frontages, each street-facing façade shall be treated architecturally as a primary façade as approved by the Planning and Development Director.
(8) Service entrances, utility closets and other similar features shall not be oriented towards a public street.
(9) Address numbers a minimum of six inches in height shall be posted in a visible location on each building.
(10) All building façades shall have a minimum height based on the street type(s), which the subject building fronts:
a. Local, private, and feeder streets: 12'
b. Primary and secondary streets: 18'
c. Boulevard streets: 24'
(11) All buildings shall have roofs surfaced with a heat-reflective material.
(12) Relationship of building to street.
a. The primary pedestrian access to all sidewalk level uses and business establishments with public or private street frontage:
1. Shall face and be visible from the public street when located adjacent to such street. When located adjacent to a street that functions as a storefront, boulevard, or primary or secondary street, said entrance shall face and be visible from such street.
2. Shall be directly accessible and visible from the sidewalk adjacent to such street.
3. Shall remain unlocked during business hours for nonresidential uses.
b. Buildings with more than four residential units at the street level shall have front-facing entrances that are directly connected to the public sidewalk with a pedestrian walkway a minimum of five feet wide. Such access shall be perpendicular to the street, unless topography prohibits, and shall be permitted to share said walkway with one adjacent unit.
(b) All single-family residential Buildings.
(1) Metal shall be permitted only as metal split seam roofing or as an architectural accent.
(2) When located on a Storefront, Primary, Secondary of Feeder Street the following additional requirement shall apply:
a. Garage doors shall not be oriented toward the street or located on the street-facing facade;
b. All new single-family detached residential dwellings shall provide a covered front porch that is a minimum of 8 feet wide and 6 feet deep.
(c) Proportion and scale of building facades. The following requirements shall apply to all newly constructed buildings over 20,000 s.f., other than single-family structures, but including multi-level parking structures:
(1) Building massing. All new development proposals shall incorporate means of reducing the apparent size and bulk of the building. Facades shall be broken up via offsets or recesses, both horizontally and vertically, in order to avoid creating a heavy or institutional appearance. The following methods for reducing the apparent size and mass of larger buildings shall be required:
a. Discontinuous building massing: Every building shall reduce its perceived height and bulk by dividing the building mass into smaller scale components. Building walls exceeding 100 continuous linear feet shall utilize offsets, such as projections, recesses, and changes in floor level.
b. Variation in building silhouettes: Variation in the roofline of buildings and offsets in pitched roofs and gables shall be required. Parapets in building masses exceeding 100 continuous linear feet shall be varied in height and projection and shall use decorative elements such as crown moldings, dental, brick soldier courses, or similar detail.
c. The principal entry area of a building shall be articulated and express greater architectural detail than other portions of the building.
(d)—(f)
Reserved.
(g) Accessory mechanical systems and features. Accessory mechanical systems, including utility meters, boxes, HVAC units, and other similar equipment shall not be located between the building and a public street. Efforts shall be taken to locate accessory mechanical system features including utility meters, boxes and other similar equipment so as to not be visible from the public right-of-way. When this is not possible or satisfied (because of existing site constraints or as required by Georgia Power or other authority), as determined by the Planning and Development Director, the following screening shall be required:
(1) Roof-mounted systems. Roof-mounted systems shall be screened with an opaque wall constructed of materials similar to the primary building.
(2) All other systems. Systems mounted on walls, ground, or elsewhere, shall be screened with an opaque wall constructed of materials similar to the primary building or sufficient landscaping to provide year-round screening. Alternatively, equipment may be ornamented with public art as approved by the Public Art Commission.