(a) Single-family detached or attached houses constructed or enlarged on a block face that is occupied by two or more existing houses shall comply with parts (a) and (b) of this subsection, Contextual lot setbacks and Single-family detached residential threshold elevation, in lieu of the standards for front yard setbacks in the "Space Dimensions Table" of Section 230-1. (b) Contextual Lot Setbacks. (1) The front setbacks of a single-family attached or detached residences subject to these setback regulations must be located within the range of front yard setbacks observed by single-family detached residences that exist on the nearest two lots on either side of the subject lot (i.e.; two lots on both sides). (2) The front yard setback shall not be required to be any greater than 40 feet by the provisions in this section, regardless of the range observed by the reference parcels. (3) If one or more of the nearest two lots on either side of the subject lot is vacant, the vacant lot shall not be considered unless an as-built survey of a demolished house completed in the last two years, by a licensed surveyor in the State of Georgia, is available. In this case, the contextual setback shall be based on the next closest lot containing a detached single-family residence in the same direction on the same block face. (4) Lots that are separated from the subject lot by a street or alley may not be used in determining the street setback range. (5) If existing lots are proposed to be subdivided, the reference parcels used to determine the setback range for the purposes of determining contextual requirements shall be those immediately adjacent to and outside the parent parcel of the subject subdivision. (6) Through lots with homes oriented toward a different street shall not be used to determine contextual setbacks. (7) These contextual street setback regulations may not be used to reduce the setback of a street-facing garage door to less than 20 feet. (8) Contextual setback requirements shall not apply between the rear wall or walls of a house and the rear property line on a through lot. (9) The front setback range for a detached house on a corner lot is required only on the block face on which the proposed front facade is located. (10) Relief from the required setback range is permitted in accordance with the following: a. Contextual setbacks can be reduced to allow the front facade to be as close as the front setback standards in the "Space Dimensions Table" of Section 230-1 if the reduction accomplishes preservation of a tree stand or specimen tree as defined by Section 320-25, or to avoid encroachment into a stream buffer. b. Contextual setbacks can be relieved to be reduced (closer to the street) or increased (farther from the street) in accordance with the administrative variances procedures of Chapter 280, Article 5. (c) Single-family detached residential threshold elevation. The front door of the threshold of the new construction or remodeled house shall be at an elevation that meets one of the following requirements: (1) No more than three feet higher or lower than the previous elevation of the front door threshold of the house prior to the proposed construction; or (2) No more than three feet higher or lower than the average grade elevation of the lot at the front building line of the proposed house; or (3) No more than three feet higher or lower than the elevation of the front door threshold of the two nearest homes on the same block face on either side of the proposed construction.