Chamblee · Zoning Ordinance
Appendix A - UNIFIED DEVELOPMENT ORDINANCE / Title 2 - LAND USE AND ZONING / Chapter 230 - STANDARDS APPLYING TO ALL DISTRICTS / Article 2 - CIVIC DESIGN
Section 230-31. Outdoor lighting.
About this text
- As published by Municode, retrieved 2026-11-14
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
- Tables are shown as their rows, with the cells separated by a bar ( | ).
(a) Purpose. The regulations of this division are intended to:
(1) Permit reasonable uses of outdoor lighting for nighttime safety, utility, security, productivity, enjoyment and commerce;
(2) Curtail and reverse the degradation of the nighttime visual environment and the night sky;
(3) Preserve the dark night sky for astronomy;
(4) Minimize glare, obtrusive light and artificial sky glow by limiting outdoor lighting that is misdirected, excessive or unnecessary;
(5) Conserve energy and resources to the greatest extent possible; and
(6) Help protect the natural environment from the damaging effects of night lighting from human-made sources.
(b) Conformance with applicable regulations. All outdoor lighting devices must comply with the provisions of this section, the building code and the electrical code, required permits and inspections, as applicable.
(c) Prohibited lighting. The following are expressly prohibited:
(1) Aerial lasers;
(2) Searchlight-style lights;
(3) Light sources that exceed 200,000 lumens or intensity in any direction of 2,000,000 candelas or more;
(4) Mercury vapor lamps;
(5) Low-sodium vapor lamps;
(6) Visually exposed neon lighting, except as part of an otherwise conforming sign pursuant to Chapter 260; and
(7) LED light strips.
(d) Exempt lighting. The following luminaries and lighting systems are expressly exempt from the regulations of this division:
(1) Underwater lighting used for the illumination of swimming pools and fountains;
(2) Temporary holiday lighting;
(3) Lighting required and regulated by the Federal Aviation Administration, or other authorized federal, state or local government agency;
(4) Emergency lighting used by police, fire, or medical personnel, or at their direction;
(5) All outdoor light fixtures producing light directly from the combustion of fossil fuels, such as kerosene and gasoline;
(6) Security lighting controlled and activated by a motion sensor device for a duration of ten minutes or less;
(7) Signage that conforms with the standards of Chapter 260.
(8) Streetscape lights authorized by the City.
(e) Regulations.
(1) Applicability.
a. The regulations of this section apply:
1. To all new developments and new buildings that require a permit;
2. When a development or building project exceeds the 70 percent redevelopment threshold as indicated in Figure 270-9.
3. Whenever existing outdoor lighting constituting 60 percent or more of the permitted lumens for the parcel is modified or replaced, no matter the actual amount of lighting already on the site.
(2) General regulations.
a. Outdoor lighting fixtures must be full cutoff and placed so as to allow no light above the horizontal as measured at the luminaire, except as herein noted in this section (as in the case of period fixtures, cutoff fixtures may be used).
b. Outdoor lighting fixtures must be located, aimed or shielded to minimize glare and stray light trespassing across lot lines and into the public right-of-way.
c. Flood or spot lamps must be positioned no higher than 45 degrees above straight down (half-way between the vertical and the horizontal) when the source is visible from any off-site residential property or public roadway.
| | | |----|----| | At Property Lines Including Rights-of-Way | Maximum Foot-candles | | At property line abutting a residential or an agricultural use | 0.5 | | At property line abutting an office or institutional use | 1.0 | | At property line abutting a commercial or industrial use | 1.5 |
- Off-Street Parking Lots | Minimum Foot-candles | Average Foot-candles | Maximum Foot-candles
- Residential areas | 0.5 | 2.0—3.0 | 4.0
- Office-professional areas | 1.0 | 3.0—4.0 | 6.0
- Commercial areas | 2.0 | 6.0—7.0 | 12.0
- Light industrial areas | 1.0 | 4.0—5.0 | 8.0
d. All light fixtures that are required to be shielded shall be installed and maintained in such a manner that the shielding is effective as described herein for fully shielded fixtures.
e. Lighting on sites consisting of multiple uses must conform to the standards of the respective uses.
f. Illumination levels are measured from any height and orientation of the measuring device at any location along the property line except the lighting of parking lots must be measured at grade with the meter sensor held horizontally at the surface.
(3) Specific uses and activities. This subsection establishes supplemental lighting regulations for specific types of uses and activities. All lighting not directly associated with the special use areas designated below must comply with all other applicable regulations of this article.
a. Outdoor sports, recreation fields and performance areas. Lighting of outdoor recreational facilities (public or private), such as, but not limited to, outdoor athletic fields, courts, tracks, special event or show areas must comply with the following regulations:
1. Facilities designed for municipal leagues, elementary to high school levels of play and training fields for recreational or social levels of play, college play, semi-professional, professional or national levels of play must utilize luminaries with minimal up light consistent with the illumination constraints of the design. Where fully shielded fixtures are not utilized, acceptable luminaries include only those that:
(i) Are provided with internal and/or external glare control louvers or lenses, and are installed so as to minimize up light and off-site light trespass and glare, and
(ii) All lighting installations must be designed to achieve the illuminance levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA RP-6).
- Light Trespass Limitations for Sports Lighting
- Environmental Zone | Pre-Curfew Limit | Post-Curfew Limit | Degrees Above Nadir (not to exceed 12,000 candela from a single fixture)
- E1 | Not allowed | 0.0 max vertical | Not allowed
- E2 | 0.25 max horizontal 1.0 max vertical | 0.10 max vertical | 82 degrees
- E3 | 0.5 max horizontal 2.0 max vertical | 0.30 max vertical | 85 degrees
- E4 | 0.75 max horizontal 3.0 max vertical | 0.60 max vertical | 88 degrees
E1 = Areas with intrinsically dark landscapes, such as national parks, areas of outstanding natural beauty, etc.
E2 = Areas of low ambient brightness, including sensitive residential areas.
E3 = Areas of medium ambient brightness, generally being urban residential areas.
E4 = Areas of high ambient brightness, which would include dense urban areas with mixed residential and commercial use with high levels of nighttime activity.
2. All events must be scheduled so as to complete all activity no later than 10:30 p.m. Illumination of the playing field, court or track is permitted after the curfew only to conclude a scheduled event that was unable to conclude before the curfew due to unusual circumstances. Field lighting for these facilities must be turned off within 30 minutes of completion of the last event of the night.
3. All light poles must be set back a minimum 60 feet from any residential property line or right-of-way.
b. Service station canopies and parking garages.
1. All luminaries mounted on or recessed into the lower surface or service station canopies and parking structures must be fully shielded and utilize flat lenses.
2. The total light output of luminaries mounted on the lower surface, or recessed into the lower surface of the canopy, and any lighting within signage or illuminated panels over the pumps, may not exceed 50 foot-candles. The total light output of other illuminated areas of a service station may not exceed 15 foot-candles.
3. Illuminance levels for the interior of parking structures, where interior lighting is visible from outside the structure, must conform to IESNA recommendation RP-20.
4. Lights may not be mounted on the top or sides of a canopy, and the sides of the canopy may not be illuminated.
c. Security lighting.
1. Security lighting must be directed towards the targeted area.
2. Sensor activated lighting must be located in such a manner as to prevent direct glare and lighting into properties of others or into a public right-of-way, and the system must be designed and maintained so that lights are not activated by activity off of the subject property.
d. Pedestrian path lighting. Lighting posts for pedestrian path lighting may not exceed 16 feet in height from finished grade.
e. Architectural accent lighting.
1. Architectural accent lighting includes fixtures used to accent architectural features, materials, colors, style of buildings, landscaping, or art. Such lighting shall have a correlated color temperature (CCT) of no more than 3,000 Kelvin.
2. Lighting fixtures may not generate glare or direct light beyond the façade onto a neighboring property or street greater than 0.5 foot-candle value.
f. Temporary lighting permits. The Planning and Development Department may grant permits for temporary lighting if the total output from the luminaries does not exceed 50 foot-candles, subject to the following regulations:
1. The lighting may not remain for more than 30 days, except that permits for a major construction project may extend to completion.
2. The lighting must be designed in such a manner as to minimize light trespass and glare.
3. Temporary recreational lighting allowed by permit must be extinguished by 10:30 p.m.
g. Parking areas.
1. All lighting fixtures servicing parking lots must be directed downward and not towards buildings or other areas.
2. Parking lots must be illuminated to a minimum illumination level of 0.4 foot-candles at grade level, and the ratio of the average illumination to the minimum illumination may not exceed 4:1.
3. Light poles used in parking lots with 100 parking spaces or less may not exceed 30 feet in height, including the base. Light poles used in parking lots with more than 100 parking spaces may not exceed 40 feet in height, including the base.
(f) Plans.
(1) Applicants for any permit for any single-family residential use required by any provision of the ordinances of the city involving outdoor lighting fixtures must submit evidence that the proposed work will comply with the outdoor lighting regulations of this division.
a. The submission must include the following information with the application for the required permit:
1. Description of all proposed outdoor illuminating devices, fixtures, lamps, supports, reflectors. The description may include, but is not limited to catalog cuts and illustrations by manufacturers.
(2) Applicants for any permit for any non-single-family use required by any provision of the ordinances of the city involving outdoor lighting fixtures must submit evidence that the proposed work will comply with the outdoor lighting regulations of this section.
a. The submission must include the following information with the application for the required permit:
1. Plans indicating the location on the premises of each outdoor illuminating device, both proposed and any already existing on the site.
2. Description of all proposed illuminating devices, fixtures, lamps, supports, reflectors. The description may include, but is not limited to catalog cuts and illustrations by manufacturers.
3. Photometric data, such as that furnished by manufacturers or similar, showing the angle of cut-off of light emissions.
4. Photometric plans must include the maximum and average light layout.
b. The above-required plans, descriptions, and data must be complete and accurate so that the Planning and Development Department is able to readily determine whether the proposal will comply with the requirements of this article.
History
(Ord. No. 743, 12-19-17; Ord. No. 757, 12-18-18; Ord. No. 776, 12-17-19; Ord. No. 799, 5-18-21)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.