Skip to content
Georgia Commons
Menu

Chamblee · Zoning Ordinance

Appendix A - UNIFIED DEVELOPMENT ORDINANCE / Title 3 - DEVELOPMENT AND PERMITTING / Chapter 320 - BUFFERS, LANDSCAPING AND TREE PROTECTION / Article 4 - TREE PRESERVATION AND REPLACEMENT REGULATIONS

Section 320-37. Tree protection and replacement plans.

About this text

  • As published by Municode, retrieved 2026-11-14
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Tree Protection Plan—Required documents. A Tree Protection Plan is a detailed plan designed to protect and preserve trees before, during and for a period of two (2) years after construction. This Protection Plan is a separate drawing that must be submitted at the same time as the Tree Survey Plan in order to qualify for a Tree Removal Permit. The Plan should list the following specifications:

(1) The identity of the tract of land upon which tree(s) sought to be removed are located.

(2) The name, address and phone number of the owner of the land and the name, address and phone number of any tenant of the property.

(3) The type, location and size as measured at the diameter breast height of the tree(s) constituting those to be protected. Only trees designated on the Tree Protection Plan will be counted toward density requirements.

(4) Locations of all specimen trees and their critical root zones (CRZ's). Indicate those specimen trees proposed for removal or for preservation. Removal of specimen trees is subject to approval by the City Landscape Coordinator. Any specimen tree proposed for removal is to be identified in terms of exact location, size and species.

(5) All tree protection zones, natural areas, landscaped areas, buffers and areas of re-vegetation. Include detailed locations and specifications for active and/or passive tree protection measures. Methods of tree protection should be indicated for all tree protection zones, including tree fencing, erosion control, retaining walls, tunneling for utilities, aeration systems, transplanting, staking, signage, etc.

(6) Limits of clearing and land disturbance such as grading, trenching, etc., where these disturbances may affect tree protection zones.

(7) The locations of all existing and proposed utility lines or easements. Include the location for any boring sites for underground utilities.

(8) Indication of staging areas for parking, material storage, concrete washout, and other areas where tree protection may be affected.

(9) A delineation of tree save areas in which trees have been inventoried for minimum site DBH calculation.

(10) Calculations showing compliance with the required minimum site DBH density using existing trees, replacement/recompense trees, and/or alternative compliance methods. Site density compliance should be demonstrated on both the Tree Protection and the Tree Replacement plans. Existing trees or stands of trees used in determining the minimum site DBH density requirement must be indicated on the drawings. All trees must be accordance with Subsection 320-39 if they are to be applied toward the minimum site DBH density. Trees with a DBH of two (2) inches or greater shall be applied to the site minimum DBH requirements.

(11) Site area (roads, utility lines, detention ponds, etc.).

(12) The locations of existing and proposed structures, paving, driveways, land disturbance, cut and fill areas, detention areas, etc.

(13) Phase lines and/or limits of construction.

(14) Location and details for all permanent tree protection measures (tree wells, aeration systems, permeable paving, retaining walls, bollards, etc.).

(15) Additional information as required on a case-by-case basis or as requested by the City Landscape Coordinator.

(b) Tree Replacement Plan standards and vegetation.

(1) The last part of the Tree Removal Permit is the Tree Replacement Plan. This plan may be included as a part of the Tree Protection Plan or may be submitted as a separate drawing. The Tree Replacement Plan includes the planting schedules along with proposed tree names (botanical and common), quantity, size, spacing and any special planting notes. Unless otherwise approved by the City Landscape Coordinator, all trees selected for replanting must be on the City's Tree Species List, see Addendum 2.0.

(2) Trees selected for planting must be free from injury, pests, disease, nutritional disorders or root defects, and must be of good vigor in order to assure a reasonable expectation of survivability. Standards for transplanting should be in keeping with those established in the International Society of Arboriculture publication Tree and Shrub Planting Manual or similar publication. Reference the American Association of Nurserymen publication American Standard for Nursery Stock (ANSI Z60, 1973) for plant material quality specifications. Reference the Manual of Woody Landscape Plants (Michael Dirr, 1983, Castle Books) or similar publication for information on tree species site requirements.

(3) The Tree Replacement Plan should also reflect the following guidelines:

a. Replanted trees shall be of the same or similar species as those removed when practical unless a change in species is appropriate to achieve the requirements of Subsection 320-3(c).

b. The use of flowering ornamental trees or plants classified as large shrubs may be included in the Tree Replacement Plan, but shall not be used for the purpose of meeting the density calculations for the site unless approved by the City Landscape Coordinator.

c. All overstory trees should be a minimum of eight (8) feet tall and have a trunk of not less than three (3.0) caliper inches. All understory trees should be a minimum of six (6) feet tall and have a trunk of not less than two (2.0) inches. In order to provide sufficient growing area for planted trees, the following minimum criteria must be observed unless otherwise approved by the City Landscape Coordinator:

1. Overstory Trees - 200 square feet of pervious root zone.

2. Understory Trees - 75 square feet of pervious root zone.

3. Up to 30% of root zone may be impervious area except for parking lot islands).

d. For new residential single-family detached dwellings, smaller caliper replacement trees shall be considered, provided the total minimum tree density goal is reached. A list of proposed plant species and sizes is to be submitted in writing to the City Landscape Coordinator.

e. All planting and staking details should be provided on the plan. Examples of acceptable details are provided in Addendum 2.0.

f. All debris from trees cut or substantially damaged should be removed from the site in a timely fashion including the removal of any portion of the tree stump above the original natural grade or elevation of land unless accepted by the City Landscape Coordinator for a specific reason such as, but not limited to, unusually large size or age.

History

The history line the source prints at the end of the section.

(Ord. No. 743, 12-19-17)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:chamblee/zoning/320-37@2026-11-14-57df7558ac

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.