--- title: Chamblee Zoning Ordinance, Section 350-16. Culverts and pipe collection system guidelines collection: local-codes id: local-code:chamblee/zoning/350-16 cite_as: Chamblee, Ga., Zoning Ordinance ยง 350-16 canonical_url: https://georgiacommons.org/code/local/chamblee/zoning/350-16 md_url: https://georgiacommons.org/code/local/chamblee/zoning/350-16.md text_url: https://georgiacommons.org/code/local/chamblee/zoning/350-16/text source_url: https://library.municode.com/ga/chamblee/codes/code_of_ordinances date: 2026-11-14 status: active jurisdiction: city:chamblee jurisdiction_name: Chamblee place_fips: "1315172" corpus_version: local-codes-chamblee-d741f937264e publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/chamblee/zoning/~appendix-a/~title-3/~chapter-350/~article-2.md previous: https://georgiacommons.org/code/local/chamblee/zoning/350-10-to-350-15.md next: https://georgiacommons.org/code/local/chamblee/zoning/350-17.md index: https://georgiacommons.org/code/local/chamblee.md branch: zoning edition: As published by Municode, retrieved 2026-11-14 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:chamblee/zoning/350-16@2026-11-14-ebe192864b --- # Chamblee Zoning Ordinance, Section 350-16. Culverts and pipe collection system guidelines > As published by Municode, retrieved 2026-11-14 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - UNIFIED DEVELOPMENT ORDINANCE / Title 3 - DEVELOPMENT AND PERMITTING / Chapter 350 - INFRASTRUCTURE / Article 2 - DRAINAGE SYSTEM (a) Storm drainage profile drawing. (1) No main line storm pipe shall be less than 15 inches diameter; (roof laterals and landscape drainage are exempted from this requirement); (2) No pipe shall have a slope greater than 12 percent; (3) If a drop in a structure is greater than five feet, a reinforced base shall be provided for that structure; (4) No Corrugated Metal Pipe (CMP) shall be used in any publicly maintained road right-of-way; (5) No outfall pipe shall have a slope greater than one percent. Maximum allowable velocity for storm sewer exit pipe is ten feet per second when flowing full or half-full, based on Manning's Formula. Energy dissipater is required for exit velocity in excess of five feet per second; (6) Open channel design must show the grade of the flow line of the channel and include a typical ditch section that provides a non-erodible velocity at design flows. Channel slopes less than one percent may be grassed; for channel shapes greater than 12 but less than three percent the designer must demonstrate calculated velocity at or less than five feet per second including a channel lining for design to accommodate the design philosophy; channel slopes over three percent must be approved by the city; (7) Crown elevations must be matched at each junction structure or the upstream crown must be higher than the downstream crown. (b) Stormwater easements specifications are provided in subsection 340-39(a)(7). ## History (Ord. No. 743, 12-19-17)