(a) Storm drainage profile drawing. (1) No main line storm pipe shall be less than 15 inches diameter; (roof laterals and landscape drainage are exempted from this requirement); (2) No pipe shall have a slope greater than 12 percent; (3) If a drop in a structure is greater than five feet, a reinforced base shall be provided for that structure; (4) No Corrugated Metal Pipe (CMP) shall be used in any publicly maintained road right-of-way; (5) No outfall pipe shall have a slope greater than one percent. Maximum allowable velocity for storm sewer exit pipe is ten feet per second when flowing full or half-full, based on Manning's Formula. Energy dissipater is required for exit velocity in excess of five feet per second; (6) Open channel design must show the grade of the flow line of the channel and include a typical ditch section that provides a non-erodible velocity at design flows. Channel slopes less than one percent may be grassed; for channel shapes greater than 12 but less than three percent the designer must demonstrate calculated velocity at or less than five feet per second including a channel lining for design to accommodate the design philosophy; channel slopes over three percent must be approved by the city; (7) Crown elevations must be matched at each junction structure or the upstream crown must be higher than the downstream crown. (b) Stormwater easements specifications are provided in subsection 340-39(a)(7).