(a) PR-D District scope and intent. Regulations in this section are the PR-D district regulations. The PR-D district identifies land areas for a variety of housing types in a multiple use district of residential and some commercial services within a planned community setting as further described in section 64-31(6) of this chapter. The PR-D district is intended to: (1) Encourage the development of large tracts of land as planned communities; (2) Encourage flexible and creative concepts in site planning; (3) Preserve the natural amenities of the land by encouraging scenic and functional open space areas; (4) Provide for an efficient use of land; and (5) Provide a stable residential environment compatible with surrounding residential areas. (b) Master plan. A preliminary master plan of the planned development shall be submitted to the zoning administrator at the time of filing for rezoning to the PR-D zoning district. The preliminary master plan shall contain a list of the proposed uses. Any use not specifically designated as a permitted use shall be prohibited. The plan shall represent an overall land use concept which is in keeping with the spirit and intent of the PR-D district as described in subsection 64-31(6) of this article. The purpose of the district is to allow for the development of higher density, owner occupied, fee simple housing in a variety of planned community settings. Said plan shall be prepared by an architect, landscape architect, engineer, or land surveyor whose state registration is current and valid and the plan shall exhibit such seal or other to validate such. The plan shall become a condition of the rezoning and any variations to said plan after rezoning approval that would increase the area of a specific land use proposed in the development shall require approval of the planning commission and city council. (c) Use regulations. Within the PR-D district, land and structures shall be used in accordance with the list of proposed uses as submitted in the master plan. All uses shall be declared in the master plan. Any use not specifically designated as a permitted use shall be prohibited. (d) Development standards. (1) Height regulations. Single-family residential buildings shall not exceed a height of 50 feet. (2) Minimum lot area per dwelling unit. a. Single-family detached. As specified in conditions of zoning. b. Townhouse/attached, 2,000 sq. ft. (3) Maximum density. a. Townhouse/attached, eight units per gross acre. b. Townhouse/attached, 1,200 sq. ft. (4) Minimum lot width. As specified in conditions of zoning. (5) Minimum PR-D development frontage, 60 feet. (6) Minimum lot frontage. As specified in conditions of zoning. (7) The use of metal panels or metal sheathing and/or standard gray concrete block on the exterior walls of any building or structure shall be prohibited with the exception that such materials may be used if finished with a product consisting of brick, stone, hard-coat stucco, or fiber cement siding. (8) Gable or hip roofs shall have a minimum roof pitch of 5/12. Both gable and hip roofs shall provide overhanging eaves on all sides that extend a minimum of one foot beyond the building wall. (9) Perimeter setback entire PR-D development. As specified in conditions of zoning. (10) Interior setbacks. As specified in conditions of zoning. (11) Accessory structure requirements.. (12) Minimum buffer requirements. As specified in conditions of zoning. (13) Minimum open space requirements. As specified in conditions of zoning. (14) Air conditioning units and HVAC systems shall be thoroughly screened from view from the public right-of-way and from adjacent properties by using walls, fencing, roof elements, or landscaping on multi- family and non-residential properties. (15) The front building façade of all principle non-residential buildings shall be oriented toward street fronts or adjacent arterial street fronts. (16) Refuse areas (dumpsters) shall be placed in the least visible location from public streets and shall be covered and enclosed on three sides with opaque walls, with the fourth side being an opaque closing gate. Height of an opaque wall shall be at least 12 inches higher than the receptacle. (17) Light fixture poles cannot exceed 40 feet in height. All site lighting shall be directed onto the site. (18) Chain link fences are not allowed in the front yards. Where allowed, all chain link fences shall not be taller than five feet in height and shall be vinyl coated, with one of the following colors: hunter green or black. (19) Building massing. Street fronting building facades greater than 150 feet in length shall be modulated with breaks in wall surfaces and materials at intervals not to exceed 150 feet, measured parallel to the street. For buildings that are three stories or less in height, each floor shall be delineated through windows, belt courses, cornices lines, or similar architectural detailing. (20) Color. Fluorescent colors shall not be employed except as accent colors. (21) Other required standards. a. The number of single-family detached residential lots consisting of less than 6,000 square feet in lot area shall be as specified in conditions of zoning. b. A traffic impact study shall be included in the master plan. c. An analysis on impacts of utility infrastructure and city services, community access and pedestrian connectivity, and schools shall be provided in the master plan. (e) Commercial requirements. The headings below contain additional provisions applicable to the PR-D district. (1) Commercial uses in the PR-D district shall not exceed 15 percent of the total development. (2) Architecture for commercial uses shall complement the design of the residential uses in the proposed development plan. (3) Commercial uses shall be located at the street level. (4) The master plan shall provide pedestrian connectivity between the residential and commercial uses. (5) Air conditioning units and HVAC systems shall be thoroughly screened from view from the public right-of-way and from adjacent properties by using walls, fencing, roof elements, or landscaping. (6) The front building façade of all principle buildings shall be oriented toward street fronts or adjacent arterial street fronts. (7) Refuse areas (dumpsters) shall be placed in the least visible location from public streets and shall be covered and enclosed on three sides with opaque walls, with the fourth side being an opaque closing gate. Height of an opaque wall shall be at least 12 inches higher than the receptacle. (8) Light fixture poles cannot exceed 40 feet in height. All site lighting shall be directed onto the site. (9) Commercial signage shall comply with the city sign ordinance. The uses (project) granted under the approved plan shall commence operations or construction within 18 months of the date of approval by the city council. If, at the end of this 18-month period, the planning director determines that active efforts are not proceeding toward operation or construction, a report may be forwarded to the city council through the planning and zoning board which may recommend that action be taken to return the property(ies) to the original zoning, following all required amendment procedures found in this chapter of the code.