Planned unit developments shall comply with the following: (1) No cul-de-sac shall be over 1,250 feet long. (2) All water mains must be six inches or larger. (3) Fire hydrants must be installed every 1,000 feet. (4) All streets must be 60 feet, R/W. (5) All subdivisions must have plans for council approval. (6) All water systems shall be installed to AWWA standards. (7) All subdivision improvements shall be paid for by the developer. (8) Concrete curb and gutters are required.