3.14. Architectural Design Standards.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Design emphasis is placed on building massing and scale. Massing will be reviewed in the context of building height, number of stories, roof configuration and building groupings.

Scale of buildings shall be appropriate to the site in question as it relates to street frontage and pedestrians. New construction shall respect the traditional style of Downtown College Park and shall be in visual harmony with surrounding structures.

A. Building Height, Width, Mass and Scale. Building heights and widths shall relate to the existing fabric of downtown and surrounding neighborhoods.

1. Widths of buildings are encouraged to consist of three (3) to four (4) bays (window and door divisions), or approximately fifty (50) to sixty (60) feet.

2. New buildings that are wider than existing structures shall incorporate a number of smaller bays into the primary façade, to maintain a cohesive scale.

3. Buildings in excess of three (3) stories or thirty-five (35) feet in height may be appropriate within two thousand (2,000) feet of the College Park MARTA station, subject to a conditional height permit.

4. Building heights of larger projects shall provide variety. A larger (taller) development shall step down in height to a maximum of thirty-five (35) feet when adjacent to a street with shorter structures on the opposite side or when adjacent to smaller, surrounding structures.

5. Large lots are encouraged to be developed with several buildings, rather than a single structure in order to help reduce the perceived size of the project.

B. Orientation. All front façades of the principal building shall face and be parallel to a public street.

1. Primary pedestrian entrances shall be oriented to the street and shall be clearly visible.

2. For buildings with commercial and retail uses, all customer entrances shall remain unlocked during business hours.

C. Building Façade. A variety of sizes is appropriate among primary façades in new developments.

1. Variations in facade treatment shall be continued through the structure, including its roof line and front and rear facades to reduce the perceived size of the building.

2. A monotonous appearance of a large building or single façade shall be minimized through the use of architectural elements within the façade which include masonry piers, stepping of the building height and width, different colors or textures, and the variation of windows and awnings.

3. Building design shall create positive open space in these variations such that they will enhance the streetscape.

4. Blank lengths of wall exceeding thirty (30) linear feet are prohibited on all building façades.

D. New Construction. New buildings shall incorporate recessed entryways into the design of the building to prevent impeding pedestrian traffic along the sidewalk while a door is opened to enter a commercial building.

1. The entryway shall be set back from the edge of the sidewalk four (4) to eight (8) feet and may make use of display cases and window panes to integrate this feature into the design of the building.

2. Buildings located on corner lots shall incorporate design features to provide architectural interest for side walls that are not considered part of the primary façade.

3. There shall be no exposed plain concrete block for visible portions of all façades.

4. Tilt up or precast concrete shall be textured with brick, aggregates, form liners, or similar methods to give visual interest to larger expanses of wall.

5. Landscaping elements shall also be added to break up larger expanses of wall.

6. Where retail or service-oriented offices front on a public right-of-way, a minimum of seventy-five (75) percent of the affected building façade shall consist of transparent surfaces, such as windows or doorways, to promote visual interest.

7. Where general office uses front public rights-of-way, a minimum of fifty (50) percent of the affected building façade shall consist of transparent or translucent surfaces.

E. Roofs. Roofs shall be designed as follows:

1. The form and pitch of the roof of new construction and additions to existing buildings shall be proportionate to surrounding structures.

2. During roof repair and replacement, new materials shall match existing materials in scale and texture.

3. Parapets shall be embellished with detailing and stepped or sloped to achieve a visually interesting yet harmonious sequence along the building façade.

4. Flat roofs shall be defined with a discernible cornice line. Variations in roof type, height, and or distinct, separate roof segments should be considered as a means of creating greater visual interest, identifying changes in use and areas of ownership, or reducing monotony.

5. Pitched roofs such as gable, hip, shed or mansard roofs shall be clad with highly durable materials such as standing seam metal, slate, ceramic or fireproof composite tiles. Use of asphalt shingles is discouraged.

6. Rooflines shall reflect interior and exterior patterns of use or ownership.

7. Roof ornamentation shall carefully consider sight lines and not allow any views of unsightly surfaces.

F. Windows and Doors. Architectural design of the structure shall determine the window and door styles selected for a project.

1. Windows and doors shall follow appropriate rhythm and scale for building massing and frontage, including a pedestrian friendly focus.

2. The arrangement, size and style of windows and doors shall be proportionate in scale to surrounding structures.

3. Entrance doors for retail and commercial buildings shall be of glass or contain significant glass to allow visibility into businesses.

4. Entries shall be recessed to allow the door to swing out without obstructing pedestrian flow.

5. Where appropriate as determined by the City Planner, sliding/folding doors that allow the activity of the business to open adjacent to and onto the public sidewalk shall be installed.

6. Replacement windows shall conform as follows:

a. Windows shall match the original materials or replicate the same appearance.

b. Windows shall require no major alterations of the openings.

c. Windows shall match the pane divisions of the original windows.

7. Bay windows on the front of buildings shall not encroach on the public right-of-way.

8. Storm windows and doors shall have minimal impact on building façades.

Owners shall consider proper weather-stripping and repairs first as an alternative to the installation of storm doors and windows.

a. New storm windows and doors shall match the color of the existing sash wherever possible.

b. Clear panes are recommended for storm doors which permit the original door to be fully visible.

G. Awnings. Awnings, canopies, and other accessory shade structures that do not restrict pedestrian or vehicular movement may encroach over the right-of-way.

1. Permitted Elements:

a. Awnings shall be made of opaque materials; the traditional use of cloth or canvas awnings is encouraged.

b. Awnings shall be of a solid through color, i.e., the underside of the awning is the same color as the exposed face.

c. Awnings shall be a color compatible with the building facade.

d. The scale of the awning, i.e., height, length, depth and overall bulk shall be compatible with the building storefront.

e. Awnings may be operable so that they can be retracted and lowered to permit the desired level of sunlight throughout the day/season.

2. Appropriate Awning Forms:

a. Where the facade of a commercial building is divided into distinct structural bays (sections defined by vertical architectural elements, such as masonry piers), awnings shall be placed within the vertical elements rather than overlapping them. The awning design shall respond to the scale, proportion and rhythm created by these structural bay elements and nestle into the space created by the structural bay, but need not be identical.

b. Awning shape shall relate to the window or door opening. Barrel-shaped awnings shall be used to complement arched windows while square awnings shall be used on rectangular windows.

c. Awnings over sidewalks shall overhang the sidewalk a maximum of five (5) feet and shall provide a minimum vertical clearance of eight (8) feet for pedestrians.

3. Prohibited Elements:

a. Awnings shall not be made of shiny, high-gloss, or translucent materials.

b. The use of vinyl or plastic as awning material is prohibited.

c. Awnings shall not cover distinctive architectural features of the building face, nor shall installation of the awning damage the structure.

d. Internal illumination of awnings is prohibited.

H. Rear Entrances. Rear façades shall be designed as an integral part of the overall building with similar materials and detail treatments as the rest of the building. If parking is placed to the rear of a building, the building's rear façade shall be welcoming in appearance. Awnings, landscaping and small wall signs identifying businesses are encouraged. Furthermore, any rear entrance shall provide adequate lighting and be designed to maximize safety.

1. If no rear building entrance is provided, a signed and lighted walkway to the front or side building entrance shall be provided and adhere to requirements for lighting as addressed in Article 7, Lighting Standards.

2. Selective use of tree planting, potted plants and other landscaping shall be used to improve the aesthetics of a rear facade.

3. A rear customer entry door design shall be compatible with the front door.

Special security glass (i.e. wire imbedded) is allowed.

I. Franchise Architecture. Franchise development is a necessary and vital component to the growth of a community. It remains important to assure that the focus of such development reflects the character of the city, and not merely the tenant. The City of College Park prizes its downtown, and encourages reflecting its architecture within this district.

1. Appropriate attributes:

a. To lend the appearance of multi-tenant occupancy, facades of multi-tenant buildings shall be varied in depth or parapet height.

b. Within planned shopping centers, distinct architectural entry identity for individual tenants' entrances shall be provided for suites exceeding ten thousand (10,000) square feet of leasable area.

c. Walls visible from roadways or parking areas shall incorporate changes in building material/color or varying edifice detail such as trellises, false windows or recessed panels reminiscent of window, door or colonnade openings, landscaping or storefront every one hundred and fifty (150) linear feet.

d. All projects shall adhere to lighting and landscaping guidelines as dictated through Article 7, Lighting, and Article 9, Tree Protection, respectively.

2. Prohibited elements:

a. Building elements shall not function as signage. The appearance of franchise architecture, where the building functions as signage is discouraged. Incorporation of franchise or business design elements unique or symbolic of particular business shall be unobtrusive and secondary to the overall architectural design.

b. Parking shall not isolate the building from the sidewalk or connecting walkways.

c. Service windows and stacking lanes.