3.36. District Standards.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Minimum Lot Area: Sewer and Water: Maximum Accessory Structures:

• 20,000 square feet • Requires connection to public water and sewer

• 2 Minimum Lot Width: Minimum Front Yard Setback: Maximum Lot Coverage:

• 100 feet • 40 feet when adjacent to an Arterial

• All primary and accessory structures, and impervious surface cannot exceed 50% of the Maximum Lot Depth: lot area. • 35 feet when adjacent to a Collector

• 3.5 times the lot width • 25 feet when adjacent to a Local Road

Minimum Lot Frontage: Minimum Side Yard Setback:

• 100 feet on a public street with access from said public street

• 15 feet

• 0 feet where no point of access or window Minimum Rear Yard Setback:

• 20 feet Additional Development Standards That Apply:

Lot/Yard Standards (LY) Height Standards (HT) Accessory Use/Structure Standards (AS) Performance Standards (PS) Public Improvement Standards (PI) Maximum Structure Height: Parking Standards (PK)

• 35 feet for the Primary Structure Fences and Walls Standards (FN)

• 25 feet for Accessory Structures Outdoor Lighting Standards (OL)