FN-01: This Fences and Walls Standards section applies to all zoning districts. Fences and walls shall be permitted in all zoning districts with a permit subject to conformance with the following requirements: A. All fences and walls shall present the non-structural face outward. B. All fences and walls may be permitted up to any property line that is not also a right-of-way line. All fences and walls shall be setback a minimum of 2 feet from all adjacent rights-of-way. C. No fence or wall may be placed in any right-of-way or any sight visibility area, as determined by the Engineering Director. D. No fence or wall may be placed in any drainage, utility, sidewalk, landscaping, access or other easement without written permission from the easement holder. E. No fence or wall may be placed in any required buffer zone that does not specifically provide for the inclusion of fences. 1. Fences specifically required by this Code for screening, swimming pools, telecommunications facilities, or other purposes may exceed the maximum heights established by this section in a manner consistent with the specific requirements of this Code. 2. The height of a fence shall be determined by measuring from the highest grade to the highest point of the fence, including any posts or finials. 3. Residential Districts: Fences and walls constructed of chain link, of ornamental metal, of ornamental masonry, or of ornamental wood, shall not exceed six (6) feet in height in any side or rear yard and shall not exceed four (4) feet in any front yard or in that portion of the side yards abutting front yards of other residential lots. For the purposes of this requirement, the front yard shall be defined as all areas located between any adjacent streets and the walls of the primary structure which face them. 4. Commercial and Mixed Use Districts: Fences and walls shall not exceed six (6) feet in height in any front, side, rear yard. 5. Industrial Districts: Fences and walls shall not exceed eight (8) feet in height in any front, side, or rear yard. F. Any fence may be prohibited if, in the opinion of the building official or the chief of police, that fence obstructs the vision of motorists to the public rights-of-way so as to create a dangerous condition, or if for some other reason such fence would endanger the public safety or general welfare. G. The use of barbed-wire, razor wire or similar fencing materials is specifically prohibited in all zoning districts, except in industrial zoned districts. Such fencing materials may be allowed upon application to and approval by the building official. H. High voltage electric fences are prohibited throughout the city; however, the construction and use of low voltage electric fences, shall be allowed in the city only as provided in this section and subject to the following standards: 1. Permit. The construction or installation of any high voltage electric fence shall not commence except with a building permit secured from the office of inspections. 2. Electrification. The energizer for electric fences must be driven by a commercial storage battery, not to exceed 12 volts DC. The storage battery must be charged primarily by a solar panel; however, the solar panel may be augmented by a commercial trickle charger. The electric fence shall not be energized unless the College Park Power Department has inspected such fence for compliance. 3. Perimeter fence or wall. Electric fences shall be completely surrounded by a non-electric fence or wall that is not less than six (6) feet tall, and the electric fence and non-electric fence or wall shall have no less than six (6) inches of space between them. 4. Location. Electric fences shall be permitted only in industrial zoned districts. 5. Setback. Electric fences shall be a minimum of twenty-five (25) feet from all perimeter property lines when adjacent to residential zoning districts. 6. Buffers. Electric fences shall not enclose a landscape buffer. 7. Height. Electric fences shall have a minimum height of six (6) feet and maximum height of eight (8) feet, but such height can be extended up to ten (10) feet if a variance is granted. 8. Warning signs. Electric fences shall be clearly identified with warning signs that read: Danger: Premises Protected by an Electric Fence at intervals of not less than twenty (20) feet and at a height no higher than five (5) feet from the ground. 9. Warnings. Electric fences shall not be energized until such signs are posted. 10. Accessibility. A Knox Box rapid entry system, unlocked by a key, shall be required and installed per the standards of the City of College Park Fire Department. 11. Power source. The power source for electrified fences shall come from an internal source and not be generated directly from a city-powered source. 12. Power Lines. Electric fence conductors shall not be mounted on support surfaces utilized for overhead power lines. 13. Indemnification. The applicant or property owner agrees to defend, indemnify, and hold harmless the city or its agents, officers, and employees from any claim, action or proceeding against the city or its agents, officers, or employees resulting from the approval and installation of an electric fence. Prior to issuance of any permits, the applicant or property owner shall execute such indemnification and hold harmless agreements reflecting the obligations required under this subsection, in such form as approved by the city attorney. 14. UL Standards. Electric fences shall meet UL standards.