--- title: College Park Zoning Ordinance, 6.37. Container Style and Modular Building Standards collection: local-codes id: local-code:college-park/zoning/6.37 cite_as: College Park, Ga., Zoning Ordinance § 6.37 canonical_url: https://georgiacommons.org/code/local/college-park/zoning/6.37 md_url: https://georgiacommons.org/code/local/college-park/zoning/6.37.md text_url: https://georgiacommons.org/code/local/college-park/zoning/6.37/text source_url: https://library.municode.com/ga/college_park date: 2026-11-11 status: active jurisdiction: city:college-park jurisdiction_name: College Park place_fips: "1317776" corpus_version: local-codes-college-park-e76ef9e027eb publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/college-park/zoning/~appendix-a/~article-6.md previous: https://georgiacommons.org/code/local/college-park/zoning/6.36.md next: https://georgiacommons.org/code/local/college-park/zoning/6.38.md index: https://georgiacommons.org/code/local/college-park.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:college-park/zoning/6.37@2026-11-11-077492968e --- # College Park Zoning Ordinance, 6.37. Container Style and Modular Building Standards > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - ZONING 3.46 / Article 6 - DEVELOPMENT STANDARDS A. Applicability of this section. 1. This section shall apply to all container style and modular buildings including buildings constructed from refurbished shipping containers. 2. "Occupied Shipping Container Buildings" shall include "Any type of building or structure made out of used shipping containers for the use of occupied commercial space. These types of container buildings are separate and distinct from the use of used shipping containers for storage units." B. Zoning Districts. 1. Container style buildings shall be prohibited in all residential district including R1, R2, R3 and RM. Modular buildings may be permitted in residential districts if the building code and standards below are met. 2. Container style and modular buildings shall be permitted by conditional use permit in mixed use districts including TOD, DC, and HC. 3. Container style and modular buildings shall be permitted in BP, OP, C1, C2, M1, and M2 districts given they meet the building code and standards of this section. C. Prohibited Uses. 1. Mini-warehouses or storage facilities of any type. 2. Accessory structure used for storage. 3. Auto storage, repair, or maintenance. 4. Storage of Hazardous Material. 5. Exceptions. i. Container style buildings may be used as a primary structure for the storage of equipment used for data, computer, battery, or electrical storage. ii. Containers used in this matter shall be completely shielded from the public right-of-way. D. Distance from similar structures. 1. No container style building shall not be located on a parcel within 2,500 feet of another parcel with container style building. 2. Other modular building types may not be located on a parcel within 2,500 feet of another building of the same type. 3. The distance requirements in this section may be varied by the Zoning Board of Appeals if the Board determines one of the following exemptions is met: i. The container or modular buildings are part of an overall master plan for multiple parcels. ii. The container or modular buildings are not visible from one another. iii. Additional façade or architectural treatments are provided. E. Construction. 1. All container style buildings must meet the IBC (international building code) container acceptance criteria (AC462) and the IBC's guidelines for container use. 2. Container style buildings are limited to 2 stories in height (no more than 2 stacked containers) unless otherwise approved for a conditional height permit by Mayor and Council. 3. All buildings shall be installed on permanent foundations in compliance with the College Park Building Code. The distance below the underside of the plywood floor sheathing to the exposed soil shall not be less than 18 inches. 4. Buildings must have the following: i. Wiring and connection for permanent electrical utility service. ii. No less than one HVAC (heating, ventilation, and air conditioning) system. iii. Insulation in the form of closed cell spray foam insulation. iv. Exclusive of any end cargo doors, a door measuring at least 19.5 square feet and one or more windows measuring at least six square feet each. 5. No container shall be placed in a location which may cause hazardous conditions, constitute a threat to public safety, or create a condition detrimental to the surrounding land use and development. 6. No container that was used for the storage or transportation of hazardous material may be converted for commercial occupancy. F. Facades and exterior walls including sides and backs. 1. The building shall be designed in a way that will reduce the strictly metal façade and will provide visual interest including cladding with wood, concrete siding, or other materials to be approved by the City Planner. 2. The building shall include architectural features that contribute to visual interest at the pedestrian scale by breaking up the building wall, front, side, and rear, with color, texture changes, wall offsets, reveals, or projecting ribs. 3. The buildings shall have exterior building materials and colors that are aesthetically pleasing and compatible with materials and colors that are used with the district. G. Street frontage. Along any public street frontage, the building design shall include at least one (1) of the following: 1. Windows, arcades, awnings or other acceptable features along at least sixty (60) percent of the building length and appropriately spaced. 2. Architectural treatment, similar to that provided to the front facade shall be provided to the sides and rear of the building to mitigate any negative view from any location off-site and any public area (e.g. parking lots, walkways, etc.) on site. H. Landscaping. 1. Parcels with container style buildings must meet the landscaping requirements established in the zoning code as well as provide additional shrubs or trees along areas in which the building is visible from the public right-of-way. I. Violations. 1. Any violations of this section will be assessed for enforcement and penalties per Article 15 of the Zoning Code. ## History (Ord. No. 2021-06, § 1, 8-17-21)