In addition to the limitations set forth in the other sections of this Article, the following limitations shall apply to the specific signs described below: A. Wall signs. No wall sign shall cover wholly or partially any wall opening, nor project beyond the ends or top of the wall to which it is attached. B. Roof signs. 1. Setback from roof edge. No roof sign shall be erected or maintained within five (5) feet of the outside wall toward which the sign faces. 2. Space between sign and roof. All roof signs shall maintain a minimum of five (5) feet of vertical clearance between the sign and roof. 3. Prohibited obstructions. No roof sign shall be placed on the roof of any building or structure in such manner as to prevent free passage from one part of the roof to any other part or interfere with openings in the roof. C. Projecting signs. 1. No projecting sign shall be placed over streets, alleys or ways available for vehicular traffic, except those provided in this Article, or maintained less than eight (8) feet above the ground level when erected over pedestrian walkways. 2. All projecting signs shall be installed at an angle of ninety (90) degrees to the building facade and shall be securely fastened to the building surface. 3. No projecting sign shall be erected within twenty (20) feet of another projecting sign. D. Temporary signs. 1. Temporary signs shall be removed from the premises within thirty (30) days from the date the sign is first placed on the lot. 2. No temporary sign may be erected or placed on any lot more than once in any six-month period for a single lot. 3. All temporary signs shall be securely installed, and shall meet all applicable safety standards as prescribed by the building code, electrical code or as promulgated by the chief building inspector and approved by Mayor and Council. 4. Under no circumstances shall any temporary sign be located so as to block the view of a permanent sign, exceed the size of any permanent sign relating to the same user, or installed in such a way as to create a safety hazard. 5. The erection or maintenance of any temporary sign in violation of this Article or any other ordinances or laws of the city shall cause the chief building inspector to give written notice to the owner thereof and to the owner of the property and premises upon which the sign is located. Such notice shall state that the sign must be removed within three (3) days. In the event the sign is not thereafter removed, the city may cause its removal and impose the cost of the removal as a lien upon the property upon which the sign is located. E. Awning signs. 1. No awning sign may be internally illuminated. 2. The sign area of any awning sign shall not exceed fifty (50) percent of the surface area of the awning. 3. Entrance sign. All entrance signs shall be placed on private property and may not be placed in the right-of-way. F. Subdivision sign. All subdivision signs shall be placed on private property and shall not be placed in the right-of-way, except that such signs may be placed in the median of a street within the subdivision, provided the recorded homeowners' associations shall assume full responsibility for the maintenance of such signs and associated improvements, that the association documents shall hold the city harmless for any and all liability associated with the sign and associated improvements and that such signs shall be compatible with the architectural style of the dwellings within the subdivision. G. Flags. 1. Ground. A flag may be flown from a metal pole permanently placed in the ground. The length of the flag shall be no greater than one-quarter () the height of the pole. This guideline applies to poles twenty (20) feet and taller. Residential flags shall not exceed three (3) feet in width or five (5) feet in length. Residential flagpoles shall not exceed twenty (20) feet in height. Flag size for small industrial and commercial buildings shall not exceed four (4) feet in width or six (6) feet in length. Flagpoles for small industrial and commercial buildings shall not exceed twenty-four (24) feet in height. Major industrial, municipal and government buildings flag sizes shall not exceed six (6) feet in width or ten (10) feet in length. Major industrial, municipal and government building flagpoles shall not exceed forty (40) feet in height. The pole may be of varying diameter, depending on the length of the flag. 2. Projecting. A flag may be flown from a metal or wooden pole attached to a bracket projecting from the side of a building or doorframe. The pole shall not exceed six (6) feet in length, or one (1) inch in diameter. The flag flying from such pole shall not exceed three (3) feet in width and five (5) feet in length. Additionally, the flag displayed in such manner shall not impede pedestrian or vehicular traffic. 3. Window. A flag may be hung in the window of either the primary facade or secondary facade of a properly zoned property. The flag area shall be considered against the percentage of window signs permitted for the zoned property as delineated in Section 9.8. 4. Limit. The number of flags (ground, projecting or window) that may be flown or displayed on each property is controlled by the limitations set forth in Section 9.8. However, a maximum of three (3) flags (ground, projecting or window) will be exempt from the limitations established in Section 9.8. Any additional flags (ground, projecting or window) that are displayed shall be considered against the allocation of the ground, projecting or window sign area permitted for each property in Section 9.8. 5. Condition of flags. All flags flown or displayed shall be in serviceable condition and fit for use. All stitching shall remain intact and the flags shall not become tattered or faded. H. Billboards. 1. Billboards may not be located within five hundred (500) feet of any residential zoning district, park, playground, recreation area, scenic area or cemetery. 2. Permits for billboards to be erected on undeveloped property shall only be considered for approval in accordance with section 3. of this Article if submitted with a sign scheme for the entire property. 3. No billboard shall have an area greater than four hundred (400) square feet nor be erected at a height greater than twenty (20) feet. 4. No billboard shall be within five hundred (500) feet of another billboard on the same side of the highway provided that multiple message billboards shall not be located within five thousand (5,000) feet of another multiple message billboard on the same side of the highway. 5. Multiple message billboards shall only be permitted under the following circumstances: a. Each message on a multiple message billboard shall remain fixed for a minimum of ten (10) seconds; b. Each transitional change shall occur within three (3) seconds or less; c. Any such billboard shall contain a default design that will freeze the message in one (1) legible position if a malfunction occurs. d. Upon a finding by the city that a multiple message billboard or any display or effect thereon causes glare or impairs the vision of a motorist or otherwise interferes with the safe operation of a motor vehicle, and upon written request by the city, the owner of the billboard shall promptly and within forty-eight (48) hours reduce the intensity of the illumination of the billboard to a level acceptable to the city or otherwise remedy the interference. 6. Except as otherwise expressly provided in this Article, mobile electronic multiple message billboards that are otherwise in compliance with this subsection and are illuminated entirely by the use of light emitting diodes, back lighting, or any other light source shall not be illuminated or otherwise in use while within the city limits. I. Certain LED signs. The following standards shall apply to all LED signs regulated hereunder; any LED sign existing before the adoption of these provisions regulated hereunder that does not comply with these standards shall be nonconforming. For the purpose of this paragraph, LED Sign shall mean a digital sign, including but not specifically limited to light-emitting diode (LED), liquid crystal display (LCD) and other similar technology signs. 1. LED signs shall only be permitted for signs located within the BP, Planned Business Park and OP, Office and Professional Districts. 2. Each such LED sign must be located a minimum of one hundred fifty (150) feet from any single family residence, or any property zoned for single family residential use. 3. No more than two (2) LED panels shall be allowed on any one (1) sign face. 4. The total area of each LED panel shall not exceed twenty (20) square feet. 5. Color of characters must contrast with the field of the sign to provide for maximum visibility and legibility, and each character on the LED panel must be the same color. The field of the sign shall be a solid color. 6. LED lights on signs shall remain, and appear to be, fixed and static. In no instance shall LED lights on signs be, or appear to be, moving, changing, flashing, or animated in any way. 7. The LED signs permitted in this paragraph shall not block sight distance for persons entering and exiting the premises. 8. Notwithstanding the provisions of this Article to the contrary, digital billboards may be permitted under the following conditions: a. For purposes of this section, Digital Billboard shall mean any LED sign that also meets the definition of a billboard in this Article. Interstate highway shall mean I-85 or I-285. b. Digital billboards shall be limited to non-residential zoning districts. c. Digital billboards shall be limited to parcels fronting on Interstate highways only, shall themselves be positioned for viewing from such Interstate highways. d. No digital billboard shall be located within five hundred (500) feet of another billboard on the same side of the Interstate highway. e. No digital billboard shall be located within five thousand (5,000) feet of another multiple message billboard (including digital multimessage billboard) on the same side of the highway. f. Notwithstanding any other provisions of this Article, digital billboards having a height up to seventy-five (75) feet shall be permitted. g. All billboards must be stationary and may not contain any visible moving parts, alternating or moving messages or have the appearance of having moving parts or messages. h. The display or message on a digital billboard may change no more frequently than once every ten (10) seconds, with a transition period of one (1) second or less. i. All digital billboards must have installed an ambient light monitor which shall continuously monitor and automatically adjust the brightness level of the display based on ambient light conditions consistent with terms of this Article. Maximum brightness levels for digital billboards shall not exceed three-tenths (0.3) foot-candles over ambient light levels measured within one hundred fifty (150) feet of the sign. Certification must be provided to the city demonstrating that the sign has been preset to automatically adjust the brightness to these levels or lower. j. Notwithstanding other provisions of this Article, the maximum allowable surface display area for a digital billboard is six hundred seventy-two (672) square feet. Such digital billboards shall be permitted up to the industry standard sign face height of fourteen (14) feet and width of forty-eight (48) feet. k. Properties having digital billboards permitted hereunder shall be unaffected by the square footage of any digital billboard permitted by the City of College Park as concerns compliance with the limitation of five hundred (500) square feet of aggregate sign area for every ten (10) contiguous acres. l. Digital billboards shall meet each of the requirements this Article that do not conflict with the provisions of this section. The repair or replacement of permitted digital displays on digital billboards shall be allowed without a permit so long as neither the size nor weight of the display is increased.