--- title: Colquitt County Zoning Ordinance, Section 16.06. Service stations collection: local-codes id: local-code:colquitt-county/zoning/16.06 cite_as: Colquitt County, Ga., Zoning Ordinance § 16.06 canonical_url: https://georgiacommons.org/code/local/colquitt-county/zoning/16.06 md_url: https://georgiacommons.org/code/local/colquitt-county/zoning/16.06.md text_url: https://georgiacommons.org/code/local/colquitt-county/zoning/16.06/text source_url: https://library.municode.com/ga/colquitt_county/codes/code_of_ordinances date: 2025-02-04 status: active jurisdiction: county:colquitt jurisdiction_name: Colquitt County county_fips: "13071" corpus_version: local-codes-colquitt-county-a00c59d1d0ec publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/colquitt-county/zoning/~appendix-a/~article-xvi.md previous: https://georgiacommons.org/code/local/colquitt-county/zoning/16.05.md next: https://georgiacommons.org/code/local/colquitt-county/zoning/16.07.md index: https://georgiacommons.org/code/local/colquitt-county.md branch: zoning edition: As published by Municode, current through 2025-02-04 edition_date_kind: current_through source_publisher: Municode version_id: local-code:colquitt-county/zoning/16.06@2025-02-04-c184bdb9b3 --- # Colquitt County Zoning Ordinance, Section 16.06. Service stations > As published by Municode, current through 2025-02-04 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - ZONING ORDINANCE / Article XVI - C-PUD, COMMERCIAL PLANNED UNIT DEVELOPMENT DISTRICT In order to regulate and control the problems of noise, odor, light, fumes, vibration, dust, danger of fire and explosion, and traffic congestion which result from the unrestricted and unregulated construction and operation of service stations, and to regulate and control the adverse effects which these and other problems incidental to the service stations may exercise upon adjacent and surrounding areas, the following additional regulations and requirements are provided herein for service stations located in the commercial planned unit development district: a. The operation of any automotive service station and garage shall observe the rules of the Safety Fire Commission as presently promulgated and amended, and future amendments thereto, as well as in accordance with NFPA 30A (1991) standards pertinent to these entities. b. Service stations shall be located having a frontage along the principal street/road of not less than 140 feet, and having a minimum area of not less than 22,000 square feet. c. Service station buildings housing an office and/or facilities for servicing, greasing and/or washing motor vehicles shall be located not less than 40 feet from any street/road lot line, and not less than ten feet from any other lot line. d. All driveways providing ingress and egress from an service station shall be not more than 30 feet wide at the property line. Not more than one curb opening shall be permitted for each 50 feet of frontage or major fraction thereof along any street/ road. No driveway or curb opening shall be located nearer than ten feet to any corner or exterior lot line, as measured along the property line, to any other driveway giving access to or from the same service station. e. A raised curb six inches in height shall be erected along all street/road lot lines, except for driveway openings. f. The entire service station area, excluding the area occupied by a building, shall be hard-surfaced with concrete or a plant mixed bituminous material, or, if any part of the lot is not so surfaced, then that area shall be landscaped and separated from all surface areas by a low barrier or curb. g. All lubrication equipment, motor vehicle washing equipment, hydraulic hoists and pits shall be enclosed entirely within a building. All fuel pumps shall be located not less than 15 feet from any lot line, and shall be arranged so that motor vehicles shall not be supplied with fuel or serviced while parked upon or overhanging any public sidewalk, street/road or right-ofway. h. A service station located on a plot having an area of 22,000 square feet shall include not more than eight fuel dispenser pumps and two enclosed stalls for servicing, lubricating, greasing and/or washing motor vehicles. An additional two fuel dispenser pumps and/or one enclosed stall may be included with the provision of each additional 2,000 square feet of plot area. i. Where a service station adjoins any property located in any residential zone, or is separated from any such property by a public alley only, a masonry wall six feet in height shall be erected and maintained along the common lot line or along the alley lot line. All masonry walls shall be protected by a fixed curb or barrier to prevent vehicles from contacting the wall. j. All exterior lighting, including illuminated signs, shall be erected and hooded or shielded so as to be deflected away from adjacent and neighboring property. k. The total fuel storage capacity of each service station shall not exceed state guidelines. l. No service station shall be located nearer than 500 feet as measured from any point on the property line to any public or private school, or playground. m. Outdoor storage or parking of vehicles other than private automobiles or tow trucks associated with the business shall be prohibited between the hours of 10:00 p.m. and 8:00 a.m. n. No fuel tank shall be filled at a service station except through a hose connected to a pump of a type approved by the Underwriters' Laboratories, Incorporated. o. No flammable or hazardous materials shall be kept or conveyed in open receptacles or in glass bottles or other breakable containers on the premises of a service station, except in glass bottles of not more than eight ounces capacity used for sample purposes, and shall not be used for cleaning purposes on such premises. No fuel pump shall be installed in any building. p. All combustible waste and rubbish, including crankcase drainings shall be kept in approved receptacles fitted with a tight cover until removed from the premises. No flammable or hazardous materials shall be allowed to flow into or be placed in the drainage system. Oil and grease shall not be allowed to accumulate on the floor. Sawdust shall not be kept in any service station or place of storage therein, and sawdust or other combustible material shall not be used to absorb oil, grease or fuel. q. All service station proprietors and attendants upon being notified by any county official of the presence of flammable or hazardous materials in sewers shall cooperate in ascertaining the reason there of. There shall be constantly maintained in good working order at least two 21 /2-gallon fully charged, portable type fire extinguishers at each service station. ## History (Ord. No. 2006-5, § 1, 10-24-06)