(a) Purpose. Buffer yards and screening are required in order to reduce the impact of a use of land on adjacent uses that are of a significantly different character, density, or intensity. Buffers shall be required to be located on any development project, as specified in this section. (b) Applicability. (1) New construction. Any new building or site improvement must comply with the buffering and screening requirements of this section. (2) Exceptions. These regulations shall not apply to the construction or renovation of a single-family detached dwelling or twofamily dwelling. (3) Maintenance and repair. An existing building or site may be repaired, maintained or modernized without providing additional buffering or screening, provided there is no increase in gross floor area or improved site area. (4) Additions. a. When an existing building is increased in gross floor area or improved site area by up to 25 percent cumulatively, buffering and screening is required for the additional floor or site area only. b. When an existing building is increased in gross floor area or improved site area by more than 25 percent cumulatively, both the existing building and site area and the additional floor or site area must conform to the buffering and screening requirements of this section. (5) Change in use. A change in use only triggers the application of these requireZONING § 90-139 ments if a previously-developed site or building has been unused for one year or longer, or when there is a specific use standard requiring buffering or screening for the new use. (c) Design standards. (1) Buffer areas shall contain no structures, parking areas, patios, stormwater detention facilities or any other accessory uses, except for a fence, wall or earthen berm which is constructed to provide the visual screening required to meet the standards of this chapter. Underground utilities and driveways may be permitted to cross a buffer if the screening standards of this chapter will subsequently be achieved. Buffer widths are established to provide areas for landscaping throughout the entire width of the buffer and not to appear as a single planted row. (2) Natural buffers may contain deciduous or perennial vegetation, but shall contain evergreen shrubs and trees suitable to local growing conditions that will provide visual screen during all seasons of the year. Natural buffers can be in the form of existing vegetation that is supplemented to provide the required separation from adjacent properties. Buffers should be designed to provide reasonable protection to adjacent neighbors from lights, sounds and other nuisance elements. The property owner shall be responsible for demonstrating the manner in which these criteria are met. (3) Structural buffers shall meet the following requirements: a. Structural barriers shall be vegetated throughout the minimum area required for the buffer around any fences or walls and upon any earthen berms, which may include grass, groundcovers, shrubs and trees. b. Trees shall be located or planted within any structural buffer at a density of not less than one tree for each 20 feet of buffer length, or portion thereof. New trees shall have a caliper of not less than two inches upon planting, and may be clustered for decorative effect following professional landscaping standards for spacing, location and design. c. Fences and walls shall present a finished and decorative appearance to the abutting property, and shall be located within two feet of the property line or on the highest elevation within the buffer area, provided that a variance in the location of such fences and walls may be granted in order to save and preserve existing vegetation where appropriate. The plan review staff will consult with the property owner to arrive at an agreement as to the optimum position for the location of the fence or wall consistent with the requirements set forth in the preceding sentence and depending on the need to address site specific conditions. d. Buffers shall be designed to provide reasonable protection to adjacent residential uses from lights, sounds and other nuisance elements of nonresidential uses. The property owner shall be responsible for demonstrating the manner in which these criteria are met. The plan for the buffers submitted by the property owner must show the types and heights of exterior light fixtures proposed and the calculations for the foot candles originating from the property on and adjacent to the property before an electrical permit will be issued. (d) Residential zoning districts. Required buffers in residential zoning districts shall meet the following requirements: (1) Width of buffer. Buffer width shall be as indicated in section 90-139(h). (2) Minimum required screening. Minimum required screening shall consist of a natural buffer, utilizing existing vegeta-tion, or, upon written approval of the planning services director or his or her designee, a planted berm which provides a visual screen to a minimum height of six feet, or any combination of existing and replanted vegetation which can reasonably be expected to create a visual screen to a minimum height of six feet within two growing seasons. (3) A minimum 25-foot natural buffer shall be maintained along the exterior boundary of a common development adjacent to a public or private road or right-of-way. Said buffer shall be fully contained in the development's common area. Such buffer shall remain undisturbed, except for areas improved as part of an attractive entrance feature. The planning services director shall approve alternate entrance buffer treatments. (e) High density residential zoning districts. Required buffers in high density residential zoning districts shall meet the following requirements: (1) Width of buffer. Buffer width shall be as indicated in section 90-139(h). (2) Minimum required screening. Minimum required screening shall consist of a natural buffer, utilizing existing vegetation, which provides visual screen to a height of six feet, or any combination of existing and replanted vegetation which can reasonably be expected to create visual screen to a height of six feet within two growing seasons. (3) Modifications. In lieu of a natural buffer, if a structural buffer is provided that creates a visual screen to a height of no less than six feet, the buffer may be reduced to a width of no less than ten feet. (f) Planned zoning districts. Required buffers in planned zoning districts shall meet the following requirements: (1) Width of buffer. Buffer width shall be as indicated in section 90-139(h). (2) Minimum required screening. a. Minimum required screening of multifamily projects as a part of a planned development shall consist of a natural buffer, utilizing exiting vegetation which provides visual screen to a height of six feet, or any combination of existing and replanted vegetation which can reasonably be expected to create visual screen to a height of six feet within two growing seasons. b. Minimum required screening of nonresidential projects as a part of a planned development shall consist of a structural buffer which creates a visual screen to a height of no less than six feet upon construction. (3) Modifications. a. Buffers may be established, increased or decreased by the board of commissioners as part of the zoning approval of the PUD, PRD, S-1, or PDD district. b. In lieu of a natural buffer, if a structural buffer is provided for a multifamily project that creates a visual screen to a height of no less than six feet, the buffer area may be reduced to a width of no less than ten feet. (g) Nonresidential zoning districts. Required buffers in nonresidential zoning districts shall meet the following requirements: (1) Width of buffer. Buffer width shall be as indicated in section 90-139(h). (2) Minimum required screening. Minimum required screening shall consist of a structural buffer which creates a visual screen to a height of no less than six feet, upon construction of such screen. (3) Modifications. a. Structural buffers in nonresidential zoning districts may be increased to a maximum height of ten feet where necessary or relocated on the site due to site-specific conditions by the planning services director or their designee during site plan review to achieve the optimum screening required. b. A natural buffer may be provided in lieu of a structural buffer if the existing and planted vegetation in the buffer area creates a visual screen to a height of six feet. c. On properties that abut property owned by the county, the board of commissioners, the county school district, the county board of education, or any other entity that is not subject to the provisions of chapter 90 of this Code, buffers may be waived or reduced during site plan review by the planning services director or their designee. d. Buffers may be reduced or waived on properties that contain or abut areas on adjacent property where floodplain and/or wetlands are present, which will provide the intended buffering protection for adjacent property. Any such request shall be made during site plan review to the planning services director or their designee and shall be reviewed in conjunction with the county stormwater compliance department. (h) Summary tables of requirements. The following tables present a summary of where buffers are required, the minimum width of such buffers, in feet, and the type of buffer. Table 1. STRUCTURAL BUFFER (width in feet) Neighboring Development Low— Moderate Density Residential District High Density Residential District Planned Zoning District NonResidential Zoning District Proposed Development R-A, R-1, R-1A, R-2, R-3, R-3A, R-4 T-R, A-R10, A-R Singlefamily Residential Multifamily Residential Office or Commercial Industrial P-1, C-1, C-C, C-2, S-1 C-3, M-1, M-2, D-C High Density Residential T-R 20 None 20 None None None None None A-R10 20 None 20 None None None None None A-R 20 None 20 None None None None None PUD 20 None 20 None None None None None Non-Residential P-1 20 20 20 20 None None None None C-1 20 20 20 20 None None None None C-C 30 30 30 30 None None None None C-2 30 30 30 30 None None None None S-1 30 30 30 30 None None None None PUD 30 30 30 30 None None None None PDD 20 20 20 20 None None None None C-3 40 40 40 40 10 None 10 None M-1 40 40 40 40 10 None 10 None M-2 40 40 40 40 10 None 10 None Table 2. NATURAL BUFFER (width in feet) Neighboring Development Low— Moderate Density Residential District High Density Residential District Planned Zoning District NonResidential Zoning District Proposed Development R-A, R-1, R-1A, R-2, R-3, R-3A, R-4 T-R, A-R10, A-R Singlefamily Residential Multifamily Residential Office or Commercial Industrial P-1, C-1, C-C, C-2, S-1 C-3, M-1, M-2, D-C Low—Moderate Density Residential R-A See Table 3 None ** None None None None None R-1 None ** None None None None None R-1A None ** None None None None None R-2 None ** None None None None None R-3 None ** None None None None None R-3A None ** None None None None None R-4 None ** None None None None None High Density Residential T-R 30 None 30 None None None None None A-R10 30 None 30 None None None None None A-R 30 None 30 None None None None None PUD 30 None 30 None 30 40 30 40 NonResidential P-1 30 30 30 30 None None None None C-1 30 30 30 30 None None None None *C-C zoning districts and above MUST install a structural buffer. **Buffer shall follow comparable lot sizes for neighboring development from Table 3. Table 3. NATURAL BUFFER FOR LOW—MODERATE DENSITY RESIDENTIAL (width in feet) Neighboring Development Low—Moderate Density Residential District Proposed Development R-A R-1 R-1A R-2 R-3 R-3A R-4 Low—Moderate Density Residential R-A R-1 25 R-1A 25 25 R-2 25 25 25 R-3 25 25 25 25 R-3A 25 25 25 25 25 R-4 25 25 (i) Additional screening requirements. In addition to the buffering and screening required in this section, evergreen screening shall be required to conceal specific areas of high visual impact or hazardous areas. Plants and a solid fence or wall, at least the height of the item being screened, but not more than eight feet tall, shall be installed around all sides, excluding access gates, of the following areas: (1) Loading and service areas. (2) Refuse collection points/recycling dropoff centers. (3) Ground level mechanical, heating and air-conditioning equipment (except for single-family detached dwellings). (4) Outdoor electrical or other above-ground utility equipment. (5) Outdoor storage lots. (6) Storage tanks. (7) Communication towers and associated equipment structures. Access gates to these areas shall be solid and, to the extent practical, not oriented to a public street. (Ord. No. 16-08, § 1(Exh. A), 6-7-2016; Ord. No. 16-29, § 1(Exh. A), 9-20-2016; Ord. No. 25-03, § 1(Exh. A), 5-20-2025; Ord. No. 25-07, § 1(Exh. A), 12-2-2025)