A. Existing and Proposed Contour Lines. Grading plans shall identify existing and proposed topographic contour lines at the interval required for erosion and sedimentation control plans, as provided in this Chapter. B. Areas to Be Disturbed. Grading plans are to show all areas to be disturbed, and existing and finished topographic contour lines. Areas where earth or fill materials will be temporarily stored are to be identified. C. Undisturbed Areas. Grading plans shall outline any area that is required to remain undisturbed, such as a natural buffer or stream greenway area, and shall identify and describe the protective fencing or staking to be placed surrounding such area. D. Effect of Area of Special Flood Hazard. If the property contains any area of special flood hazard, the 100-year flood plain, grading plans in and around the flood plain shall be designed in conformance to all requirements relating to flood damage prevention provisions of this UDO.