A. Reduction in Spaces. Unless otherwise provided herein, a reduction in the required number of parking spaces may be granted as a variance by the Board of Zoning Appeals or as a waiver to a planned development approval granted by the Council. B. Increase or Decrease in Number of Required Parking Spaces. As applicable to the type of development order, the Director may authorize an increase or decrease in the number of parking spaces in an amount not to exceed ten percent of the required number of spaces. C. Additional Parking. 1. Variance. Excluding planned developments, any application which requests an increase of parking equal to or greater than ten percent of required parking shall be considered by the Board of Zoning Appeals as a variance. 2. Planned Developments. Any request for an increase of parking equal to or greater than twenty-five percent of required parking which affects a planned development shall be considered as request for approval of a waiver by the Council. 3. Standards for Additional Parking Spaces. An application to provide parking in excess of the minimum requirements shall comply, as applicable, with the standards for a variance or the standards for a planned development waiver. In addition, the requests shall consider the additional standards listed below. (A) Additional Open Pervious Space. Additional open space, at a ratio of 1.0 square feet for each additional square foot of paved parking and vehicular circulation area, shall be provided. The additional pervious open space shall be provided as additional landscaping, pedestrian amenities, or pervious open space and shall be calculated and identified on the project site plan. This additional open space shall not be counted as complying with any open space, landscaping or other similar requirements of this UDO. (B) Enhanced Site Appearance. The additional open space and landscaping shall be utilized to enhance the visual appearance of the site, the vehicular entries, and the parking areas. The method for visual enhancements shall be indicated in the application for development approval. Table 4.3.3. Off-Parking Street Parking Standards Category of Use Parking Spaces Required Additional Standards (GSF= Gross Square Feet) Residential Dormitory, Fraternity or Sorority Residence To be Determined Parking study required Dwelling, Accessory 1 per unit Dwelling, Multifamily 1.5 per dwelling with none or one bedroom 2. per dwelling with 2 or more bedrooms 1 per 250 GSF of office space 1 per 25 units for guest parking. Dwelling, Single-family, Attached 2 per dwelling Garage may count as 1 space. Dwelling, Single-family, Detached 2 per dwelling Garage may count as 1 space. Dwelling, Townhouse 2 per dwelling (1) Garage may count as 1 space. (2) Remaining space cannot be located in front yard. (3) Separate parking area for all or some of required parking may be provided. Dwelling, Two Family 2 per dwelling Garage may count as 1 space. Dwelling, Zero Lot Line 2 per dwelling Garage may count as 1 space. Home Occupation To be determined As required by Director Guest Cottage 1 per cottage Loft Dwelling See "Second Floor Dwelling" See "Second Floor Dwelling." Manufactured Dwelling 2 per dwelling Mobile Home Dwelling 2 per dwelling Mobile Home, Park 2 per dwelling 1 per 250 GSF of office space 1 per 25 units for guest parking. Category of Use Parking Spaces Required Additional Standards (GSF= Gross Square Feet) Models, Residential 4 per model (1) Director may approve centralized parking for a site with multiple models. (2) All parking subject to the following: Parking for disabled with be paved and provide paved access to walkways. Other parking can be surfaced with materials acceptable to the City Engineer. Permanent parking for models to be paved as required by this UDO. Personal Care Home, Type I 3 per home (1) Garage may count as 1 space. (2) Parking design must be consistent with area character. Personal Care Home, Type II 1 per 4 residents 1 per 250 GSF of office space (1) Garage may count as 1 space. (2) Parking design must be consistent with area character. Personal Care Home, Type III 1 per 2 beds Parking study may be required. Second Floor Dwelling 1 per dwelling with none or 1 bedroom 1.5 per dwelling with 2 or more bedrooms (1) Parking may be provided using one or more of the following methods: •Onsite parking •Shared parking •Off-site parking •Reserved parking in a garage (2) Agreement for long-term parking must be acceptable to City Attorney. (3) Parking must be located with 1,500 feet, via shortest pedestrian route, of the dwelling. (4) Not more than 25% of parking may be provided in free on-street public parking. Civic and Public Assembly Halls 1 per 3 permanent seats 1 per 200 GSF of meeting area (without permanent seating) 1 per 250 GSF of office space Required parking to be provided for other uses such as bars or lounges, restaurants, retail, etc. Cemeteries and Mausoleums To be Determined Parking study required Club or Lodge, Membership Only 1 per 200 GSF space of floor area Club or Lodge, Membership Only, Notfor-Profit 1 per 200 GSF space of floor area Convent or Monastery To be Determined Parking study required Cultural Facilities 1 per 3 permanent seats 1 per 600 GSF of facility (without permanent seating) 1 per 250 GSF of office area Parking study may be required Hospice 2 spaces per bed Hospitals 2 spaces per bed (1) Parking study may be required. 2) Required parking to be provided for other uses such as associated business or professional offices, medical offices, clinics, laboratories, etc. Category of Use Parking Spaces Required Additional Standards (GSF = Gross Square Feet) Places of Worship, 250 or more Seats Same as Places of Worship, Less than 250 Seats Same as Places of Worship, Less than 250 Seats Public Uses 1 per 250 GSF of office floor area 1 per 250 GSF of meeting area (without permanent seating) (1) Parking study may be required. 2) Required parking may be provided for other uses such as schools, day care, etc. Schools, Public and Private Elementary and Middle/Junior 2 spaces per classroom Parking study may be required Schools, Public and Private, High Schools 5 spaces per classroom Parking study may be required Schools, Specialized To be determined Parking study required Shelter, Homeless To be determined Parking study required Shelter, Temporary To be determined Parking study required Universities or Colleges, To be determined Parking study required Recreation Amusements, Indoors Bowling Alley 2 per lane Required spaces per additional uses Video Parlor 1 per 4 machine Other uses without fixed seats/equipment: 1 per 200 GSF of enclosed area. Amusement, Outdoors 10 per acre Parking study may be required Cryptocurrency Mining 5 total spaces N/A Golf Course 20 per 9 holes or portion thereof 1 per 300 square feet of clubhouse Required spaces per additional uses such as restaurants, meeting rooms, etc. Parking study may be required Recreation, Active 10 spaces per acre when located in association with a park, school, place of worship or similar use. 25 spaces per acre when a principal use. Recreation, Passive 5 spaces per acre when located in association with a park, school, place of worship or similar use. 10 spaces per acre when a principal use. Recreation Centers, Private Swimming Pool 20 spaces minimum 1 per 5 members 1 per 200 GSF of floor area Parking study may be required Recreational Establishment 1 per 400 GSF of floor area Parking study may be required Shooting Range, Indoors 1 per individual bay, range or station 1 per 250 GSF of office space Shooting Range, Outdoors 1 per individual bay, range or station 1 per 250 GSF of office space Tennis Center or Club To be determined Parking study required Theater, Drive-in To be determined Parking study required Theater, Indoor 1 per 3 seats Parking study may be required Theater, Indoor 1 per 3 seats or 1 per 25 GSF of floor area of largest room without fixed seating Category of Use Parking Spaces Required Additional Standards (GSF = Gross Square Feet) Agricultural-Related Uses Apiculture To be determined As required by Director Chipmill To be determined As required by Director Equestrian, Commercial To be determined Parking study required Equestrian, Private None Forestry None Groves None Greenhouse and Nursery, Wholesale To be determined Parking study required Produce Stand To be determined As required by Director Commercial and Personal Services Adult Entertainment 1 per 250 GSF of floor area Artisans To be determined As required by Director Arts and Crafts Sales 1 per 250 GSF of floor area Auto/Truck Paint and Body Shop 1 per 150 GSF of enclosed area Auto/Truck Rental, 1 per 250 GSF of office area 1 per rental auto Auto/Truck Repair, Major 1 per 150 GSF of enclosed area Auto/Truck Repair, Minor 1 per 150 GSF of enclosed area Auto/Truck Sales, New and Used 1 per 250 GSF of enclosed display area 1 per 4,500 GSF of outdoor sales 1 per 250 GSF of service bay Auto/Truck Service Station 3 per bay Minimum of 10 spaces required Auto/Truck Tire Sales, and Installation 1 per 250 GSF of office area 1 per service bay Auto/Truck Upholstery Shop 1 per 250 GSF of office area 1 per service bay/repair area Auto/Truck Wash and Detail Facility 1 per 250 GSF of office area Other spaces as determined by Director Banks and Financial Institutions 1 per 250 GSF of office area Banquet Facility 1 per 100 GSF of indoor and outdoor seating area Parking study may be required Bars and Lounges 1 per 75 GSF of floor area Bed and Breakfast Homestay 2 per dwelling 1 per rental room Parking must compatible with area. Parking must be located off-street. Bed and Breakfast Inn 2 per building with rental rooms 1 per rental room Parking must compatible with area. Parking must be located off-street. Boarding or Rooming House 1 per bedroom 1 per 25 units for guest parking. Boat, Trailer and Marine Sales 1 per 250 GSF of office area 1 per 2,000 GSF of shop area Building and Construction Trades Office and Shop 1 per 250 GSF of office area 1 per 2,000 GSF of shop area Category of Use Parking Spaces Required Additional Standards (GSF = Gross Square Feet) Building Supplies, Retail 1 per 250 GSF of floor area Check Cashing Facilities 1 per 250 GSF of floor area Clinic, Medical or Dental 1 per 250 GSF of floor area Clinic and Hospital, Veterinary 1 per 250 GSF of floor area Consignment Shop 1 per 250 GSF of floor area Convalescent or Nursing Facility 1 per 250 GSF of office or administrative area 1 per 3 beds Convenience Store, no Gas Sales 1 per 250 GSF of floor area Convenience Store, with Gas Sales 1 per 250 GSF of floor area 1 per 2 gas pumps Data Processing Office 1 per 250 GSF of floor area Parking study may be required Day Care, Type I None None Day Care, Type II 1 space per 10 clients 1 pickup/drop-off space per 10 clients 1 space per van or bus If approved by Director, parking spaces for principal use may substitute for required parking. Day Care, Type III 1 space per 10 clients 1 pickup/drop-off space per 10 clients 1 space per van or bus Parking study may be required Day Labor Employment Office 1 per 250 GSF of floor area Dry Cleaning and Laundry, General 1 per 250 GSF of floor area Dry Cleaning and Laundry Stations 1 per 250 GSF of floor area Emergency Care Clinic 1 per 250 GSF of floor area Employment Agencies 1 per 250 GSF of floor area Equipment Sales, Service and Rental 1 per 250 GSF of floor area Extermination Service 1 per 250 GSF of floor area Adequate parking for all service vehicles Farm Equipment Sales and Service 1 per 250 GSF of floor area 1 per 4,500 GSF of outdoor sales Film and Video Studio To be determined Parking study required Flea Market To be determined Parking study required Fruit and Vegetable Market 1 per 250 GSF of enclosed floor area 1 per 4,500 GSF of outdoor sales Funeral Home 1 per three seats 1 per 25 GSF of floor area of largest room without fixed seating Furniture and Home Furnishing Sales 1 per 250 GSF of floor area Gift and Antique Shop 1 per 250 GSF of floor area Grocery Store 1 per 250 GSF of floor area Health and Fitness Facility 1 space per 200 GSF of floor area Parking study may be requested Category of Use Parking Spaces Required Additional Standards (GSF = Gross Square Feet) Hotel, Motel or Inn 1 per sleeping room 1 per 3 permanent seats 1 per 100 GSF of meeting area 1 per 250 GSF of office space Required spaces per additional uses Parking study may be requested. Additional uses include areas open to the public such as bars, lounges and restaurants. Kennel, Board or Breeding 1 per 250 GSF of office plus 1 per 300 GSF of animal boarding and run Laboratory, Medical, Dental or Veterinary 1 per 250 GSF of floor area Laundry, Coin Operated 1 per 250 GSF of floor area Mail and Packing Store 1 per 250 GSF of floor area Manufactured and Mobile Homes Sales 1 per 250 GSF of floor area 1 per 4,500 GSF of outdoor sales Massage Therapy 1 per 250 GSF of floor area Nursery and Garden Supply, Retail 1 per 250 GSF of office or administrative area 1 per 1,000 GSF of outdoor display area Nursery, Wholesale 1 space per 4,500 GSF of outdoor area Parking study may be required Office, Business and Professional 1 per 250 GSF of floor area Office, Medical and Dental 1 per 250 GSF of floor area Parking study may be requested for largescale medical office facilities. Office, Veterinary 1 per 250 GSF of floor area Oil Change Facility 5 total spaces N/A Package and Liquor Store 1 per 250 GSF of floor area Paint, Glass and Wallpaper Stores 1 per 250 GSF of floor area Parking Garage, Commercial None Parking Lot, Commercial None Pawn Shops 1 per 250 GSF of floor area Personal Care Home, Type I None Personal Care Home, Type II 1 per 2 beds 1 per 250 GSF of office or administrative area Personal Care Home, Type III 1 per 2 beds 1 per 250 GSF of office or administrative area Parking study may be required Personal Services 1 per 250 GSF of floor area Parking study may be required Pharmacy or Drug Stores 1 per 250 GSF of floor area Print Shop 1 per 250 GSF of floor area Recreational Vehicle Park See Additional Standards As provided in Chapter 3 Repair Services, Accessory 1 per 250 GSF of floor area Repair Services, General 1 per 250 GSF of floor area Repair Services, Limited 1 per 250 GSF of floor area Category of Use Parking Spaces Required Additional Standards (GSF = Gross Square Feet) Restaurant, Accessory To be determined Parking study required. Parking may not be required if all users are generated by principal use or uses. Restaurant, Fast Food 1 per 75 GSF of floor area Parking study may be required Restaurant, General 1 per 75 GSF of floor area Parking study may be required Restaurants, Specialty 1 per 75 GSF of floor area Parking study may be required Restaurant, Take-out 1 per 75 GSF of floor area Parking study may be required Retail Sales, General 1 per 250 GSF of floor area Parking study may be required School, Vocational and Non-academic To be determined Parking study required Tattoo and Body Piercing Shop 1 per 250 GSF of floor area Taxidermy 1 per 250 GSF of floor area Television and Studio 1 per 250 GSF of floor area Transitional Housing Facility, Type I To be determined Parking study required Transitional Housing Facility, Type II To be determined Parking study required Transient Lodging 1 per bed 1 per 250 GSF of floor area Parking study may be required Upholstery Shop 1 per 250 GSF of floor area Used Merchandise/ Second Hand Goods Store 1 per 250 GSF of floor area Video Game and Amusement Parlor 1 per 250 GSF of floor area Video Rental and Sales 1 per 250 GSF of floor area Manufacturing and Industrial Auto, Vehicle and Truck Storage and Maintenance Facility 1 per vehicle to be stored 1 per service bay for maintenance 1 per 1,000 GSG of floor area Beverage Production and Bottling 1 per 2,000 GSF of floor area Building Supplies, Wholesale 1 per 2,000 GSF of floor area Bulk Storage, Flammable 1 per 2,000 GSF of floor area Bulk Storage, Nonflammable 1 per 2,000 GSF of floor area Cold Storage and Distribution 1 per 2,000 GSF of floor area Computer Assembly 1 per 2,000 GSF of floor area Concrete Batching and Asphalt Plant 1 per 2,000 GSF of floor area Contractor's Storage Yard and Office 1 per 2,000 GSF of floor area Cryptocurrency Mining 5 total spaces N/A Distribution and Warehousing 1 per 2,000 GSF of floor area Dry Cleaning and Laundry Plants 1 per 2,000 GSF of floor area Category of Use Parking Spaces Required Additional Standards (GSF = Gross Square Feet) Equipment Storage, Outdoor To be determined As required by Director Express or Parcel Delivery Service 1 per 2,000 GSF of floor area Food Processing 1 per 2,000 GSF of floor area Hazardous Waste Disposal Facilities 1 per 2,000 GSF of floor area Junk, Salvage or Auto Wrecking Yards 1 per 2,000 GSF of floor area Manufacturing, Heavy 1 per 2,000 GSF of floor area Manufacturing, Light 1 per 2,000 GSF of floor area Moving, Storage and Transfer 1 per 2,000 GSF of floor area Outdoor Advertising and Sign Fabrication 1 per 2,000 GSF of floor area Publishing, Printing and Binding 1 per 2,000 GSF of floor area Recycling Collection Box 1 per box May be included as part of required parking associated with the location of the recycling box Recycling Collection Center 1 per 2,000 GSF of floor area Recycling Collection Facility 2 per facility Storage, Self Service 1 per 75 storage units 2 per manager's/security quarters 4 per office Tire Retreading and Recapping 1 per 2,000 GSF of floor area Towing Services 1 per 2,000 GSF of floor area 1 per vehicle to be stored Vehicle/Truck Storage 1 per 250 GSF of office area 1 per vehicle to be stored Warehousing and Distribution, General 1 per 2,000 GSF of floor area Wholesale, General 1 per 2,000 GSF of floor area Communications, Mining, Transportation and Utilities Airports To be determined Parking study required Bus and Railway Passenger Stations To be determined Parking study required Helipad, Accessory To be determined Parking study required Heliport 2 per approved landing area Additional parking may be required by Director Mining and Extraction To be determined Parking study required Railroad Yard To be determined Parking study required Sanitary Landfill To be determined Parking study required Telecommunications and Digital Exchange 1 per 2,000 GSF of floor area Terminal, Truck, Freight, Rail, or Water To be determined Parking study required Category of Use Parking Spaces Required Additional Standards (GSF = Gross Square Feet) Utility Plant To be determined Parking study required Utility, Major To be determined As required by Director Utility, Minor To be determined As required by Director Wireless Communications Facilities 1 per tower May be waived by Director Accessory, Similar and Temporary Uses Accessory Uses None Similar Use Number of spaces required for the use to which compared Temporary Building or Structure To be determined As required by Director Temporary Use or Special Event To be determined based upon application and nature of use or event As required by Director D. Bicycle Parking in Lieu of Minimum Parking. 1. Applicability. Commercial buildings and multi-family residential buildings may elect to reduce their minimum parking requirements by providing bicycle parking at a rate of exchange of one standard parking space for every eight units of bicycle parking provided. Maximum allowable exchange will be determined by the Planning Director on a case by case basis. Rate of exchange Parking Requirement Units of Bicycle Parking Parking Reduction 3 or fewer Not eligible for reduction. Not eligible for reduction. Minimum of 4 8 units 1 Space Minimum of 5 16 units 2 Spaces Minimum of ... 8 units = 1 space ... 2. Function and Design. The recommended bike rack by the Association of Bicycle and Pedestrian Professionals is the inverted "U" design. This design is economical, secure, and well designed to meet the needs of many types of bicyclists and bicycles. Other designs may be used provided that they meet the functional criteria described below. Functional Criteria: (A) Shall support the bicycle frame in at least two places. (B) Must be designed in such a way as to allow the use of both cable and "U" locks. (C) Must be designed in such a way as to allow bicycles with different types of frames to lock to the rack. (D) Must be made of a material that is weather resistant and is difficult to cut with hand tools or saws. (E) The racks shall be cemented or bolted into concrete to prevent theft or vandalism. 3. Placement and Setbacks. The bicycle racks must be placed within 75 feet of an entrance and in a visible, well-lit area. The bicycle racks may be placed in separate locations on the property but may not be reduced to fewer than two racks per location. Bicycle racks must be at least 24 inches away from buildings and five feet away from fire hydrants and infrastructure. The minimum distance between two bike racks placed side by side should be no less than 30 inches. If the bike racks are to be located within a parking lot or area with traffic, it is recommended that physical buffers or signage be created to protect bicyclists and notify vehicles to exercise caution.