Section 6.4.4. Resource Conservation Subdivision Lot Standards.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
The following standards apply to the layout and minimum requirements for all lots within a resource conservation subdivision.
A. Minimum Lot Area and Width. Notwithstanding any calculated number of "base" or bonus lots, all lots within a resource conservation subdivision must meet or exceed the minimum requirements listed below, depending on the sewage disposal system utilized and the distance or buffering from adjacent property.
1. Lots Located Near Adjacent Land. Any lot in a resource conservation subdivision that is located within 100 feet of the periphery of the development shall have the same or greater lot size and lot width as the minimum required by the zoning of the property adjacent to the conservation subdivision closest to said lot. For the purposes of this requirement, the term "adjacent to" shall also mean "across the street from."
2. Lots Located Away From or Buffered From Adjacent Land. The following shall control the minimum lot size and width of lots in a resource conservation subdivision that are located 100 feet or more from the periphery of the development.
(A) Lots Served by Sanitary Sewer. Lots in a resource conservation subdivision that are connected to public sanitary sewer shall meet or exceed the following minimum lot sizes and widths, depending on the distance or buffering from the periphery of the development, as follows:
(1) For lots located 100 feet or more from the periphery of the development, the minimum lot size shall be 80% of the Usable Area of the subdivision (Table 6.4.2) divided by the total number of Allowable Lots (Table 6.4.4).
(2) For lots located between 100 feet and 350 feet from the periphery of the development, the minimum lot width shall be 70% of the minimum required by the zoning of the conservation subdivision or 100 feet, whichever is less. By way of example, in the RE1 district (which has a minimum lot width of 125 feet) the lots in a resource conservation subdivision could be 87.5 feet wide, while in the RE5 district (which requires a minimum lot width of 200 feet) the lots in a resource conservation subdivision could be 100 feet wide (70% of 200 = 140 feet;
100 feet is less).
(3) The minimum lot width shall be 60% of the minimum required by the zoning of the conservation subdivision or 100 feet, whichever is less, under either of the following situations:
(a) The lot is located between 100 feet and 350 feet from the periphery of the development and is buffered from the adjacent property by an opaque screen, or
(b) The lot is located more than 350 feet from the periphery of the development.
(B) Septic Tank and Community Sewage Disposal System Lots.
(1) For lots served by individual on-site septic tank systems, the minimum lot size shall be the minimum size established by the Muscogee County Health Department. These minimum lot sizes may be adjusted in accordance with the provisions of the Environmental Protection Chapter of this Ordinance, to protect significant groundwater recharge areas.
(2) For lots served by a community sewage disposal system, minimum lot sizes shall be as approved by the Muscogee County Health Department under rules of the Georgia Department of Human Resources.
(3) In no case shall the minimum lot size and minimum lot width of septic tank or community sewage disposal system lots in a conservation subdivision be less than the sizes and widths allowed for similarly located sewered lots.
(C) Opaque Screen Defined. For the purposes of this Section, the following definitions apply:
(1) Opaque means impenetrable to view, or so obscuring to view that features, buildings, structures, and uses become visually indistinguishable.
(2) Screening means a method of visually shielding or obscuring one abutting or nearby structure or use from another. Screening may consist of any combination of the following; existing or planted vegetation comprised of trees and understory shrubs; masonry walls or all-weather (non-wooden) fencing; earthen berms or natural topography.
Table 6.4.5 Conservation Subdivision Lot Sizes and Widths Lot <100 Feet from Periphery Lot Located Between 100 and 350 Feet from Periphery Lot >350 Feet from Periphery With 100-Foot Setback With 100-Foot Opaque Screen Minimum Lot Size Same as Nearest Adjacent Zoning 80% of Average for Subdivision* 80% of Average for Subdivision* 80% of Average for Subdivision* Minimum Lot Width Same as Nearest Adjacent Zoning 70% of Zoning Requirement** 60% of Zoning Requirement** 60% of Zoning Requirement** *Average for Subdivision is the Usable Area divided by the Total Allowable Lots.
**The minimum lot width required by the zoning district in which the conservation subdivision is located.
NOTE: Minimum lot sizes subject to Health Department requirements if public sanitary sewer not available.
B. Maximum Number of Lots. In no event is the total number of lots in a resource conservation subdivision to exceed the Total Allowable Lots permitted under these regulations, which totals both the practical development capacity of the subdivision under current zoning (the "base" lots) plus the total "bonus" lots.
C. Other Minimum Lot Requirements. Setbacks shall be established in the preliminary plat.
Setbacks shall be appropriate for the reduced lot size.
History
(Ord. No. 21-063, 12-14-21)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.