Sec. 8-7-86.1. Design standards for exterior lighting.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Purpose. The purpose of this section is to promote public safety, nighttime vision, natural resource conservation, community values and aesthetics by establishing standards for the design and application of exterior lighting sources and fixtures for nighttime use. The specific regulatory objectives of this section are as follows:

(1) Promote nighttime visibility by directing appropriate levels of illumination upon intended targets;

(2) Redress the disabling visual effects of glare and excessive illumination, and the extreme contrasts between brightly lighted areas and the lower ambient levels of adjacent areas;

(3) Limit light trespass across property lines, and its intrusive and devaluing effects upon nearby private and public property; and

(4) Limit light pollution to restore natural cycles of light and dark to the indigenous natural environment and darken the night sky by reducing the unnecessary transmission of upward light.

(b) Applicability. For all zoning districts, land uses, developments and buildings that require a permit, all exterior lighting fixtures shall meet the requirements of this section. All building additions or modifications of 25 percent or more in terms of additional dwelling units, gross floor area, or parking spaces, either with a single addition or with cumulative additions subsequent to the effective date of the ordinance from which this provision is derived, shall invoke the requirements of this section for the entire property, including previously installed and any new exterior lighting. Cumulative modification or replacement of exterior lighting constituting 60 percent or more of the permitted lumens for the parcel, no matter the actual amount of lighting already on a nonconforming site, shall require compliance with the requirements of this section. Additions or modifications of less than 25 percent to existing uses, and that require a permit, shall require the submission of a complete inventory and site plan detailing all existing and any proposed new exterior lighting. Any new lighting on the site shall meet the requirements of this section with regard to shielding and lamp type.

(c) General exterior lighting standards.

(1) Exterior lighting for all land uses and developments shall be limited to incandescent, fluorescent, metal halide, color corrected high pressure sodium, and LED light only.

(2) All exterior lighting shall be shielded and directed downward, except for spotlighting on landscaping, foliage or escarpments. Notwithstanding any applicable provision for exterior lighting set forth herein, all spotlighting on landscaping, foliage or escarpments:

a. Shall be shielded;

b. Shall not create any disabling or nuisance glare; and

c. Shall conform to the illumination levels as set forth in Section 8-7-86.1(g).

(3) All exterior lighting shall be designed, installed, located, and maintained such that light trespass onto abutting properties and the public right-of-way is prevented, and any light generated on that property is kept within the boundaries of that property.

(4) The opaque housing for all exterior lighting shall mask the direct horizontal surface of the lamp.

The light shall be directed to ensure the illumination is only pointing downward onto the ground surface, with no upward escaping light permitted to contribute to sky glow, in order to prevent light trespass.

(5) Luminaires may be controlled with dimmers, motion sensors or time switches in order to manage light output, assist in reducing energy usage and lowering impacts on the dark night sky.

a. Dimmers, motion sensors and time switches that control the hours of illumination, shall remain on the applicable Eastern Standard Time in effect throughout the year.

b. Motion sensors shall be installed in such a manner as to prevent the trespass of light onto abutting properties or onto the public right-of-way.

c. Motion sensor systems shall be designed, installed and maintained so that its luminaires are not activated by activity on abutting properties or the public right-of-way.

(6) Direct light emissions shall not be visible above the roof line, or beyond the edge of any structure or object.

(7) In no case shall any lighting impair the vision of motorists on adjacent public rights-of-way.

(d) Aesthetics. All exterior lighting shall be architecturally compatible with the building style, material, and colors. When required in parking areas, the following provisions shall also apply to all exterior lighting:

(1) Luminaires shall have curved arms to focus light downward.

(2) Directional floodlights and cobra style and shoebox style lighting fixtures are prohibited.

(e) Mounting height. Fixture mounting height shall be appropriate for the project and setting. The overall height of all lighting within parking lots shall not exceed 30 feet in height from finished grade to the top of the light fixture. Lower mounting heights are encouraged where sites are located adjacent to residential areas or other sensitive land uses. Use of low, bollard-type fixtures that are three to four feet in height, may be provided in order to guide and direct pedestrians along sidewalks, trails and paths.

(f) Light fixtures. All light fixtures shall be a full cutoff luminaire whose source is completely concealed with opaque housing, and shall not be visible from any abutting property or the public right-of-way. This provision includes lights on mounted poles, as well as architectural display and decorative lighting visible from the public right-of-way. Light fixtures shall be designed, installed, located and maintained in such a manner that the cone of light is not directed at any property line or the public right-of-way in order to prevent the spillover effect of light. The same type of lighting must be utilized for all fixtures and light sources on the site.

(g) Illumination levels. All exterior lighting shall be designed so that the level of illumination is measured in lumens (lu) per acre, with the exception of exterior lighting for landscaping, foliage and escarpments.

(1) Specific to landscaping, foliage and escarpments in all zoning districts.

a. The maximum lamp allowance (lumens) shall not exceed 2,200 lu.

(2) Specific to the R-A zoning district.

a. The maximum lamp allowance (lumens) shall not exceed 6,500 lu per acre.

i. All luminaires shall be full cutoffs.

(3) Specific to the RS-20, RS-14, TH, TND, RMH, RM and GV-RV zoning districts.

a. The maximum lamp allowance (lumens) shall not exceed 17,000 lu per acre.

i. All luminaires shall be full cutoffs.

(4) Specific to the O-I, BN, MxD, BG, D, GV-NV and GV-UV zoning districts.

a. The maximum lamp allowance (lumens) shall not exceed 44,000 lu per acre.

i. All luminaires shall be full cutoffs.

(5) Specific to the HSB and I-D zoning districts.

a. The maximum lamp allowance (lumens) shall not exceed 60,000 lu per acre.

i. All luminaires shall either be full cutoffs or semi-cutoffs.

(h) Canopy lighting. Lighting underneath canopies for service stations or similar uses shall be restricted to no more than 40 lu per square foot of canopy. All luminaires shall be recessed into the ceiling of the canopy. Lighting for ATM machines shall be recessed, and mounted flush with the actual canopy above the ATM machine, and shall also comply with the latest requirements identified within the Illuminating Engineering Society of North America (IESNA) Lighting Handbook or as established by federal regulations.

(i) Wall packs and sconces. Wall packs and sconces may be used only at service entrances to buildings and shall not be used to draw attention to the building or provide general building or site lighting. Wall packs on the exterior of a building shall be shielded and aimed so that the center of the light beam is no more than 62 degrees above nadir.

(j) Security lighting. All security lighting shall be directed towards the targeted area.

(k) Exemptions. The following lighting practices and systems are exempt from the provisions of this section:

(1) All temporary emergency lighting needed by police, fire or other emergency services;

(2) All hazard warning luminaires required by federal or state regulatory agencies;

(3) All vehicular luminaires;

(4) Security lighting controlled and activated by a motion sensor device;

(5) Underwater lighting used for illumination of swimming pools and fountains;

(6) Seasonal decorations;

(7) All exterior light fixtures producing light directly from the combustion of fossil fuels, such as, but shall not be limited to, natural gas, kerosene and gasoline;

(8) Exterior sports, recreation fields, or performance areas;

(9) Pedestrian and street lighting fixtures;

(10) Traffic control signals and devices;

(11) Exposed neon signs and LED signs that are no greater than two square feet in area, and are positioned on the interior as a window sign that is not more than five feet from the principal pedestrian entrance of the business;

(12) Covered lighting for balconies, decks, patios and porches, provided that such lighting does not exceed 2,200 lumens;

(13) Any exterior lighting temporarily installed for periodic events approved by City Council (i.e.

carnivals, circuses, concerts, fairs, festivals) provided that all such lighting is extinguished immediately upon the conclusion of the event or activity; and

(14) Signs meeting the standards of Chapter 5 in this title.

(15) String lights may only be used for ambiance for outdoor dining or gathering spaces with the following conditions:

a. The string of lights shall contain individual bulbs that hang below the wiring that is located within a UL listed weatherproof protective covering.

b. The individual bulbs shall be no less than one inch and no greater than four inches in diameter.

c. The individual bulbs shall contain a visible filament, be a 40-watt equivalent or less, and provide a Kelvin temperature no greater than 2,700 degrees.

(l) Prohibited lighting. The following lighting practices and systems are prohibited:

(1) Aerial lasers, promotional beacon lights, search lights, strobe lights and all other similar high-intensity luminaires;

(2) The use of colored, exterior neon (either enclosed or exposed) or other similar lighting in the R-A, RS-20, RS-I4, TH, TND, RMH, RM and GV-RV zoning districts;

(3) The use of neon, LED ribbon, LCD and all other similar bulbs, strips, and rope lighting used for exterior lighting, or to outline any architectural element of a structure such as, but shall not be limited to, doors, roof lines, and windows, excluding signs as regulated in Chapter 5 of this title;

(4) The use of glass tubes filled with argon, krypton, neon or other gas, and used for exterior lighting, or to outline any architectural element of a structure such as, but shall not be limited to, doors, roof lines and windows;

(5) The use of mercury vapor;

(6) Any luminaires exceeding the maximum lamp allowance (lumens) imposed for the zoning district;

(7) Any internally illuminated canopies constructed from a transparent or translucent plastic material, and attached to any structure;

(8) Excessive illumination of buildings or site features shall be avoided. Roof lighting and down-lighting washing exterior walls is prohibited; and

(9) Any lighting installed inside doors or windows, or behind clear or transparent panels so as to be visible on the exterior of the building if such lighting would be prohibited by this section as exterior lighting.

(m) Lighting plan. A lighting plan shall be required for all permits triggering reviews under this section in the RM, O-I, BN, MxD, BG, D, HSB, I-D, GV-NV and GV-UV zoning districts. When required, all lighting plans shall include the following information:

(1) A site plan indicating the location of all proposed luminaires;

(2) A description of all luminaires, including lamps, housings provided as catalogue illustrations from the manufacturer;

(3) Photometric data furnished by the manufacturer showing the downward angle of light emission;

(4) The contact information for either the professional engineer or architect (registered and licensed in the State of Georgia) responsible for the preparation of the exterior lighting plan;

(5) The contact information for the tenant, person, owner or agent that is in charge of the property;

and

(6) Any other additional information as required by the City Manager or his/her designee in order to ensure compliance with the provisions in this section.

(n) Reference to professional standards. In administering the provisions in this section, the City Manager or his/her designee may consult or rely on professional standards for exterior lighting which may include, but shall not be limited to, those that are or may in the future be published by IESNA, or a similar reputable professional association.

(o) Conflicts. Where in conflict with any other provision in Chapter 7 of this title, the more stringent provision shall take precedence.

History

The history line the source prints at the end of the section.

(Ord. No. 926, § 2, 5-15-2013; Ord. No. 952, § 1, 3-19-2014; Ord. No. 970, § 3, 9-17-2014; Memo of 8-15-2016; Ord. No. 1397, § 1, 12-18-2024)