Cook County · Zoning Ordinance
Appendix A - ZONING ORDINANCE SECTION 1 ENACTMENT, SHORT TITLE, JURISDICTION, PURPOSE
10-4.4. Permitted Uses.
About this text
- As published by Municode, current through 2020-04-06
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
The following are requirements for specific uses in the
Groundwater Recharge Area Protection District:
a. All above-ground chemical or petroleum storage tanks, having a minimum volume of 660 gallons, shall have secondary containment for 110% of the volume of such tanks or 110% of the volume of the largest tank in a cluster of tanks. Such tanks used for agricultural purposes are exempt, provided they comply with all Federal requirements.
b. New agricultural waste impoundment sites shall be lined if they are within:
1) a high pollution susceptibility area;
2) a medium pollution susceptibility area and exceed 15 acre-feet in size; and
3) a low pollution susceptibility area and exceed 50 acre-feet in size.
As a minimum, the liner shall be constructed of compacted clay having a thickness of one-foot and a vertical hydraulic conductivity of less than 5 &timeds;10-7 cm/sec or other criteria established by the Natural Resources Conservation Service.
c. New homes served by a septic tank/drain field system shall be on lots having minimum size limitations as follows, based on application of Table MT-1 of the DHR Manual (hereinafter DHR Table MT-1). The minimums set forth in Table MT-1 may be increased further based on consideration of other factors (set forth in Section A-F) of the DHR Manual.
1) 150% of the subdivision minimum lot size calculated based on application of DHR Table MT-1 if they are within a high pollution susceptibility area;
2) 125% of the subdivision minimum lot size calculated based on application of DHR Table MT-1 if they are within a medium pollution susceptibility area;
3) 110% of the subdivision minimum lot size calculated based on application of DHR Table MT-1 if they are within a low pollution susceptibility area.
d. New manufactured home parks served by septic tank/drain field systems shall have lots or spaces having minimum size limitations as follows, based on application of Table MT-2 of the DHR Manual (hereinafter DHR Table MT-2). The minimums set forth in Table MT-2 may be increased further based on consideration of other factors (set forth in Section A-F) of the DHR Manual.
1) 150% of the subdivision minimum lot or space size calculated based on application of DHR Table MT-2 if they are within a high pollution susceptibility area;
2) 125% of the subdivision minimum lot or space size calculated based on application DHR Table MT-2 if they are within a medium pollution susceptibility area;
3) 110% of the subdivision minimum lot or space size calculated based on application of DHR Table MT-2 if they are within a low pollution susceptibility area.
e. Lots of Record approved prior to the adoption of this ordinance are hereby exempted from the requirements of (C) and (D) above.
f. New facilities which handle hazardous materials, of the types (listed in Section 312 of the Resource Conservation and Recovery Act of 1976, excluding underground storage tanks) and in amounts (10,000 pounds or more on any one day) shall perform their operations on impervious surfaces and in conformance with any applicable federal spill prevention requirements and any local fire prevention code requirements.
g. Permanent storm water infiltration basins shall not be constructed in areas having high pollution susceptibility.
h. Any new wastewater treatment basin shall have an impermeable liner.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.