Utility plans for all extensions, additions, improvements and/or modifications for the water distribution, and sanitary sewer collection and natural gas distribution systems shall be prepared by a Georgia registered professional engineer. At least three copies of the plans shall be submitted to the Department of Community Development for review and comment. Within thirty days of submittal of the plans, the Department will either approve the plans or make comment on items requiring changes and/or additional information. When not approved, the cycle of plan submittal and review will be repeated until the plans can be approved by the Department. Information to be shown on the plans shall consist of not less than the following: (a) Existing facilities and features in the vicinity of utility construction which affects or could be affected by such construction. Items include but are not limited to streets, rights-of-way, buildings, driveways, parking lots, fences, tree lines and railroads. (b) All drainways, lakes, streams, creeks, channels, wetlands, and drainage facilities. (c) All existing utilities and appurtenances in the vicinity of utilities construction which affect or could be affected by such construction. The utility type, size, depth, material and location in relation to utilities improvements should be indicated. ( d) Existing and proposed property and easement lines and land lot and land district lines intersecting utility line construction. (e) New utilities construction including as applicable, but not limited to, pipelines, manholes, lift stations, force mains, valves, fittings, fire hydrants, meters, casings, services facilities, special construction and details for connections to existing utilities. Pipe sizes and materials shall be indicated on the plans. Include horizontal geometry as necessary to define location of new utilities. (0 Profiles of sanitary sewers showing existing ground surface, sewers, manholes with top and invert elevations, line lengths and grades, crossing utilities, and limits for special construction. (g) Benchmarks for vertical control. (h) Name of the development, names, addresses and telephone numbers of developer and developer's engineer, engineer's seal, north arrow, scale and date. Plans shall be prepared in conformance with the following: (a) All elevations shall be based on and tied to U.S. Coast and Geodetic Survey mean sea level datum. (b) Plan drawing shall be at a scale of at least 1 inch equals 100 feet. In developed or congested areas, a scale of 1 inch equals 20 feet or less shall be utilized. (c) For profile drawings, the horizontal scale shall be the same as that used for associated plan drawings. The vertical scale shall be at least 1 inch equals 10 feet. A 1 inch equals 5 feet vertical scale is often necessary to properly depict pipeline conditions. (d) The desired drawing size is 24 inches by 36 inches. In no case shall drawings be larger than 30 inches by 42 inches nor smaller than 11 inches by 17 inches. (e) Utilities construction may be shown on street improvement plans provided the resulting drawings are clear, legible and plainly show all necessary information.