(a) Park construction permit required. In any district where manufactured home parks are permitted, the applicant shall submit to the Chief Codes Official a site plan of the park subject to the conditions of this section. No person shall proceed with the improvement of a manufactured housing park or trailer park until an application for the construction of such park has been reviewed by the Chief Codes Official, and, upon approval of the application and site plan, a permit to construct the proposed park, hereinafter referred to as the park construction permit, has been issued. The application for a permit to construct a manufactured housing park shall include the following: (1) The name and address of the applicant. (2) The location and legal description of the property upon which the park is proposed to be placed. (3) A complete plan of the proposed park at a scale of not more than 100 feet to one (1) inch and showing the shape, area, and size of the site; street and driveway layout, including distance notations; the location and grouping of manufactured housing lot stands and accessory buildings; the placement and sizes of utilities; all manufactured housing lot boundaries and other data pertinent to the requirements of this Ordinance. (4) Plans and specifications of all buildings, improvements, and facilities constructed, or to be constructed, within the manufactured housing park. (5) Such further information as may be requested by the Chief Codes Official to facilitate the determination of whether the proposed park will comply with all legal requirements. The application and all accompanying plans and specifications shall be filed in triplicate. No park construction permit shall be issued except in accordance with this Ordinance. (b) Permit expiration. Ifno substantial construction progress has been made within six (6) months of the date of the issuance of the park construction permit, the permit becomes invalid and must be renewed. For the purpose of this section, "substantial construction" includes final site grading and the installation of utilities and is considered to be approximately forty percent (40%) of total site improvements. (c) Building permit required. No person shall park a manufactured home on an individual lot until a building permit therefore has been issued by the Chief Codes Official. No manufactured housing building permit shall be issued except in accordance with this Ordinance. ( d) Certificate of occupancy required. A Certificate of Occupancy issued by the Chief Codes Official is required in advance of the use or occupancy of manufactured homes on manufactured home lots in approved manufactured home parks. No Certificate of Occupancy shall be issued unless the lot or building or structure complies with all the provisions of this Ordinance. A record of all Certificates of Occupancy shall be kept o:'1 file in the office of the Chief Codes Official and a copy shall be furnished, on request, to any person having a propriety or tenancy interest in the building or land involved. 760.2 General standards. Manufactured home parks must meet the following standards: (a) Compliance with other laws. No manufactured home shall be admitted to any park unless it can be demonstrated that it meets the requirements of any additional, pertinent laws and regulations of the city. (b) Minimum rental period. No space shall be rented for residential use of a manufactured home in any such park except for periods of thirty (30) days or more. (c) Initial occupancy of park. The minimum number of spaces completed and ready for occupancy before the first occupancy is permitted shall be ten (10) spaces. (d) Site requirements. The park shall be located on a well-drained site properly graded to insure drainage and freedom from stagnant pools of water. The site shall not be exposed to objectionable smoke, noise, odors, the possibility of insect or rodent infestation or other adverse influences. (e) Recreational space. Not less than eight (8) percent of the gross site area of the park shall be set aside for recreational use. (f) Water Supply. An adequate supply of pure, potable water for drinking and domestic purposes shall be supplied by pipes. to all buildings and manufactured housing lots within the park. Each manufactured housing stand shall be provided with an approved cold water connection and a tap (hydrant), constructed in accordance with the plumbing standards adopted by the City of Cordele. (g) Sanitation. Each park shall provide at a minimum the following sanitation facilities and services: (l) Refuse collection station. One refuse collection station shall be provided for each twenty (20) families or fraction thereof, not more than two hundred (200) feet from any home served, and shall be conveniently located for collection. If individual refuse containers are used on the manufactured home site, these containers must be submerged in the ground with only the top portion extending above the ground level. In lieu of a submerged unit, stands may be provided to hold the cans and to screen them from conspicuous view. (2) Environmental control. The area around and underneath each manufactured home shall be kept clean and free from collections ofrefuse, rubbish, glass bottles, or other unsightly material. (3) Sewage disposal. Each manufactured housing stand shall be provided with a sanitary sewer of at least 4 inches in diameter, which shall be connected to receive all waste from the manufactured home. The sewer in each manufactured housing stand shall be connected to discharge the waste into a sewer system that meets the health requirements of the State of Georgia and the City of Cordele. ( 4) Sewage drain connections. Manufactured housing drain connections shall be of approved semi-rigid and non-collapsible hose, having smooth interior surfaces and no less than 3 inches outside diameter, nor less in size than the manufactured housing outlet. Drain connections shall be equipped with a standard screwor clamp-type fitting. While a manufactured housing stand is unoccupied or the drain is not used, the sewer opening shall be closed with an approved closure or cap. (h) Fire protection. Every manufactured housing park shall have an adequate fire protection system with water pressure and fire hydrants of such type, size, number, and location as to satisfy applicable regulations of the Cordele Fire Department currently in force, provided further that no open fires or burning of trash, leaves, or other refuse shall be permitted within the boundaries of any manufactured housing park without a permit from the Cordle Fire Department. 760.3 Park service facilities. Convenience establishments of a commercial nature, including stores, laundry and dry cleaning establishments, and pick-up laundry and dry cleaning agencies, and beauty shops and barber shops may be permitted in manufactured home parks provided that such establishments and the parking areas primarily related to their operations meet the following requirements: (a) They shall not occupy more than ten percent (10%) of the area of the park. (b) They shall be subordinate to the residential use and character of the park. (c) They shall be located, designed, and intended to serve frequent trade or service needs of persons residing in the park. (d) They shall present no visible evidence of their commercial character from any portion of any residential district outside the park.