1.02. Materials.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

A. Posts. Posts shall be a minimum of five feet long and either wood or steel posts may be used.

Wood posts shall be at least three inches in diameter, or one 2×4 and straight enough to provide a fence without noticeable misalignment. Steel posts shall have a minimum weight of 1.3 pounds per foot, and have projections for fastening wire to the fence.

B. Woven wire fence. Wire fence fabric shall be at least 32 inches high, and shall have at least six horizontal wires. Vertical wires shall be spaced 12 inches apart. The top and bottom wires shall be at least ten gauge. All other wires shall be at least 121 /2 gauge.

C. [Filter fabric.] Filter fabric shall be composed of strong, rot-proof synthetic fibers formed into a fabric of either the woven or non-woven type. Either type of fabric shall be free of any treatment or coating which might significantly alter its physical properties after installation. The fabric shall contain stabilizer and/or inhibitors to make the filaments resistant to deterioration resulting from exposure to sunlight of heat. The fabric shall be a pervious sheet of synthetic fibers oriented into a stable network so that the fibers retain their relative position with respect to each other.

The fabric shall meet the following physical requirements:

Physical Requirements Physical Property Test Method Requirements Tensile Strength ASTM D1682 Grab Test using 1" square jaws and a travel rate of 12"/minute 100 lbs. min Grab Elongation ASTM D1682 Grab Test using 1" square jaws and a travel rate of 12"/minute 30% ± 10% EOS (Equivalent Opening Size) Corps of Engineers Guide Specification CW 022115, November, 1977

100 Sieve min 40 Sieve max Ultraviolet Stability ASTM D1682 Grab Test using 1" square jaws and a travel rate of 12"/minute. Test to be made after 180 days direct exposure to sunlight on a horizontal plane.

80 lbs. min Bursting Strength ASTM D751 Diaphragm Bursting Tester 175 psi min The contractor shall furnish certified test reports with each shipment of material attesting that the fabric meets the requirements of this specification.

D. Wire staples for wooden posts. Wire staples shall be a No. 9 gauge and shall be at least 1½ inches long.

1.03 Installation. The contractor shall install a temporary silt fence as shown on the plans or as directed by the engineer.

1.04 Maintenance and removal. The contractor shall maintain the silt fence until the project is accepted or until the fence is removed, and shall remove and dispose of silt accumulations at the silt fence when so directed by the engineer. Filter fabric shall be removed and replaced whenever it has deteriorated to such extent that it reduces the effectiveness of the silt fence.

Sec. 2 - Clearing and Grubbing Right-of-Way.

2.01 Description. This work shall consist of clearing, grubbing, removing and disposing of all vegetation and debris within the limits of construction and easement areas adjacent to the right-of-way, as shown on the plans or as directed by the engineer, except such objects as are designated to remain or are to be removed in accordance with other sections of these specifications.

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:cusseta-chattahoochee/zoning/1.02@2026-11-11-f23a2e5eeb

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Cusseta-Chattahoochee County unified government Zoning Ordinance, 1.02. Materials | Georgia Commons