1. Storm sewers: Storm sewers and drains shall be provided in each subdivision. They shall be designed to carry not less than the stormwater accumulated from a rainfall expected to occur once in 25 years, with a runoff of 90 percent for pavements and buildings and a variable runoff factor depending upon topography or ground for other purposes. Storm drain pipes shall consist of reinforced concrete, bituminous coated corrugated metal or bitumized fiber pipe. The storm sewer system shall be designed and sized to accommodate and provide for future extensions. The entire storm sewer system shall be approved by the county engineer or the duly appointed agent of the commission of the Unified Government of Cusseta-Chattahoochee County prior to its installation. 2. Drainage swales and ditches: All drainage swales and ditches must be a minimum of six feet wide with a 4:1 slope on each side. They must be constructed of sod, asphalt or concrete sufficient to prevent erosion. 3. Driveways, masonry mailboxes: All driveways shall slope away from streets or roads. No masonry mailboxes will be allowed on roads and streets where the posted speed limit exceeds 30 MPH. 11.8 Storage of certain vehicles and equipment. The storage of certain vehicles and equipment (defined as motor vehicles eligible for licensed road use with license plates two years old or older) is prohibited in residential districts for time periods in excess of 72 hours unless such vehicles and equipment are stored in a carport, enclosed building, or behind the nearest portion of a building to a street. 11.9 Airports. Proposed public airports shall be so located and of sufficient size to meet Federal Aviation Agency requirements and not constitute a nuisance to surrounding uses.