A. General. Classes and specific requirements for each class of concrete are tabulated in the concrete mix table. The specific class of concrete to be used in a particular component of a structure will be shown on the plans or called for in the specifications. Various classes of concrete for specified uses shall be as follows: Class AAA - Prestressed concrete Class AA1 - Precast concrete as called for on plans Note No. 1: This class may be used as high-early strength concrete if approved by the engineer. The engineer may approve the use of Type III cement in concrete used for this purpose. The engineer may also specify the rate of compressive strength development when this concrete is used to expedite the contract. The contractor shall not be granted additional compensation for the use of this class of concrete when it is used at his request or used to expedite the contract. Class AA - Bridge superstructure concrete or precast concrete as called for on plans. Class A - General purposes Note No. 2: Class A concrete deposited in water, hereinafter referred to as seal concrete, shall be non-air entrained with ten percent additional cement and sufficient additional water to provide a six to eight inch slump. Class B - Massive section or lightly reinforced sections or miscellaneous nonstructural concrete. Class CS (Portland cement concrete subbase) Note No. 3: Class CS (Portland cement concrete base): This class to be used as a subbase where required by the plans. Concrete subbase may be composed of a mixture of Portland cement and graded aggregate or Portland cement, aggregate, and sand. B. Admixtures. Additives are required when specified herein or as directed by the engineer. 1. Air-entraining admixtures. Air entraining additives are required for all bridge structure concrete except seal concrete and non-exposed footings. The agent may be used in other concrete to improve workability when job or materials conditions dictate. When used as an option to improve workability or when required, the amount of entrained air shall not exceed the upper limit of entrained air content requirement. 2. Retarding admixtures. Concrete retarding additives shall be used in bridge concrete when the average temperature is above 65 degrees F. (average of expected high and the predicted low). Normally, the additives will not be required for bridge curbs, handrails, crosswalks, or other appurtenances constructed separately from the decks. The use of retarders may be waived by the Engineer in substructure concrete can be placed within one hour after batching. 3. Water reducing admixtures. Water reducing agents may be used in Class AA concrete for bridge decks when conditions do not require the use of retarder. The agent may be used in other concrete when job or materials conditions dictate a reduction in water requirements or when minimal retardation of set is desired. Type "F" water reducing admixtures may be allowed by the engineer where requested by the contractor. Bridge sections containing duct enclosures for stressing tendons may be constructed with concrete utilizing Type F (AASHTO:M-194) water reducer as approved by the engineer. 4. Fly ash. Fly ash may be used as an additive in all concrete to promote workability and plasticity. Fly ash may be used as a partial replacement for Portland cement in all concrete, except class "CS", provided for the following limits are met: a. The quantity of cement replaced shall be no more than eight percent by weight. b. Cement shall be replaced by fly ash at the rate of 1.5 to 2.0 lbs of fly ash to 1.0 lbs. of cement. c. The fly ash mix shall conform to the provisions of Table C-1. d. Type IP cement shall not be used in mixes containing fly ash.