On each lot where a building, structure, or use exists, off-street parking shall be provided in accordance with the requirements of table 9.1. No existing facility used for off-street parking shall be reduced in capacity to less than the minimum required number of spaces, increased in capacity to more than the maximum number of spaces, or altered in design or function to less than the minimum standards, unless specifically provided for in this article.

Unless otherwise noted, the parking requirement shall be based on the gross square footage of the building or buildings devoted to the particular use specified.

Table 9.1 Minimum and Maximum Number of Off-Street Parking Spaces Required Use

Minimum Parking Required Maximum Parking Permitted

COMMERCIAL USES

1. Animal hospital; kennel One per 400 square feet One per 250 square feet

2. Appliance sales and repair One per 500 square feet One per 300 square feet

3. Art gallery One per 400 square feet One per 300 square feet

4. Automated teller machine, no drive-through Two per machine Three per machine

5. Auto parts store One per 500 square feet One per 300 square feet

6. Automobile sales One per 200 square feet of repair space plus one per 400 square feet of showroom/ office One per 150 square feet of repair space plus one per 300 square feet of showroom/ office Use Minimum Parking Required Maximum Parking Permitted

7. Automobile service and repair One per 250 square feet One per 200 square feet

8. Bank, credit union, savings and loan One per 300 square feet (also see stacking requirements for drive-through facilities)

One per 200 square feet (also see stacking requirements for drive-through facilities)

9. Barber shop or beauty parlor One per 300 square feet One per 250 square feet

10. Bed and breakfast inn Two for the owner-operator plus one per guest bedroom

Two for the owner-operator plus one per guest bedroom

11. Carpet or floor covering store One per 300 square feet of retail sales and office area, plus if applicable, warehouse requirements for designated storage, receiving, and shipping area One per 250 square feet of retail sales and office area, plus if applicable, warehouse requirements for designated storage, receiving, and shipping area

12. Car wash, staffed or automated Two stacking spaces for each car wash lane plus two drying spaces per lane Three stacking spaces for each car wash lane plus two drying spaces per lane

13. Contractor's establishment One per 300 square feet of office space and one per 2,000 square feet of outdoor storage One per 250 square feet of office space and one per 1,500 square feet of lot outdoor storage

14. Convenience store One per 200 square feet One per 150 square feet

15. Dance hall One per 125 square feet One per 75 square feet

16. Day care center One per 500 square feet One per 375 square feet

17. Funeral home or mortuary One per four seats in largest chapel One per three seats in largest chapel

18. Furniture and home furnishing store One per 600 square feet One per 300 square feet

19. Grocery store One per 300 square feet One per 250 square feet

20. Hardware store One per 400 square feet One per 300 square feet

21. Health or fitness club One per 200 square feet One per 150 square feet

22. Hotel, extended stay 1.5 per unit lodging unit Two per lodging unit

23. Hotel or motel One per lodging unit, plus one per each 150 square feet of banquet, assembly, meeting, or restaurant seating area

1.2 per lodging unit, plus one per each 100 square feet of banquet, assembly, meeting, or restaurant seating area

Use Minimum Parking Required Maximum Parking Permitted

24. Laundromat One for each three washer/ dryer combinations One for each two washer/ dryer combinations

25. Nursery or garden center One per 300 square feet plus one per 1,500 square feet

outdoor sales or display area One per 250 square feet plus one per 1,000 square feet outdoor sales or display area

26. Office One per 300 square feet One per 250 square feet

27. Open air sales One per 250 square feet of indoor floor space plus one per 600 square feet of outdoor sales One per 200 square feet of indoor floor space plus one per 500 square feet of outdoor sales

28. Personal service establishment One per 250 square feet One per 200 square feet

29. Photofinishing laboratory One per 250 square feet One per 200 square feet

30. Photographic studio One per 300 square feet One per 250 square feet

31. Restaurant, bar, or tavern One per 125 square feet One per 75 square feet

32. Retail store One per 275 square feet One per 250 square feet

33. Self-storage facility (mini-warehouse) One per 40 storage units One per 25 storage units

34. Service station One per 250 square feet of office space plus two per service bay One per 200 square feet of office space plus three per service bay

35. Shopping center One per 275 square feet One per 225 square feet

LIGHT INDUSTRIAL USES

36. Manufacturing, processing, assembling One per 1,300 square feet One per 1,000 square feet

37. Warehouse One per 2,000 square feet One per 1,500 square feet

38. Wholesale One per 1,000 square feet One per 600 square feet

GOVERNMENT—INSTITUTIONAL USES

39. Assembly hall;

auditorium; nonprofit club or lodge One per four seats in room with greatest seating capacity or one per 40 square feet in largest assembly area

without fixed seating One per three seats in room with greatest seating capacity or one per 30 square feet in largest assembly area

without fixed seating

40. Church, temple, synagogue and place of worship One per four seats in room with greatest seating capacity or one per 40 square feet in largest assembly area

without fixed seating One per three seats in room with greatest seating capacity or one per 30 square feet in largest assembly area

without fixed seating Use Minimum Parking Required Maximum Parking Permitted

41. Government office One per 300 square feet One per 250 square feet

42. Hospital 1.5 per bed Two per bed

43. Library One per 400 square feet One per 300 square feet

44. Museum One per 500 square feet One per 300 square feet

45. Nursing home One per four beds One per three beds

46. Post office One per 200 square feet One per 150 square feet

47. School One per 300 square feet One per 200 square feet

48. School for the arts One per 300 square feet One per 200 square feet

49. School, trade or business One per 200 square feet One per 150 square feet

RESIDENTIAL USES

50. Apartment, one bedroom 1.5 per unit plus 0.1 per unit for guest space

Two per unit plus 0.2 per unit for guest space

51. Apartment, two bedroom 1.5 per unit plus 0.1 per unit for guest space

Two per unit plus 0.2 per unit for guest space

52. Apartment, three bedroom 2 per unit plus 0.2 per unit for guest space Three per unit plus 0.2 per unit for guest space

53. Home occupation (see provisions for home occupations)

54. Residence within building containing a nonresidential use One per unit 1.5 per unit

55. Single family detached or attached; duplex Two per unit Four per unit

RECREATIONAL FACILITIES

56. Amusement park Per parking generation study funded by applicant and approved by the zoning director

57. Athletic field 20 spaces per field 25 spaces per field

58. Billiard hall/amusement arcade One per 200 square feet One per 150 square feet

59. Bowling alley Two per each bowling lane (add parking for billiard hall/amusement arcade, if provided) Three per each bowling lane (add parking for billiard hall/amusement arcade, if provided)

60. Community center One per 300 square feet One per 250 square feet

61. Golf course 2.5 per hole Three per hole

62. Golf driving range, principal use

0.75 per tee 1 per tee

63. Ice- or roller-skating rink One per 200 square feet One per 150 square feet

64. Miniature golf Two per hole Three per hole Use Minimum Parking Required Maximum Parking Permitted

65. Stadium or sport arena One per twelve feet of bench seating

One per ten feet of bench seating

66. Swimming pool - subdivision amenity One per 150 square feet of surface water area One per 100 square feet of surface water area

67. Swimming pool - public One per 125 square feet of surface water area

One per 75 square feet of surface water area

68. Tennis or racquet ball court Two per court Three per court

69. Theater, cinema One per four fixed seats One per three fixed seats Retail facilities with over 250 parking stalls shall require a minimum of one standard size stall clearly marked in yellow on pavement "EMERGENCY PARKING ONLY." The location of the parking stall shall be as close as possible to major building entries.

History

The history line the source prints at the end of the section.

(Ord. No. 2024-1112(2), § 1(Exh. A), 11-12-2024)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:demorest/zoning/89-118@2026-11-11-4561048760

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Demorest Zoning Ordinance, Sec. 89-118. Minimum and maximum number of parking spaces required | Georgia Commons