(a) General standards. The building types detailed in this section define the required building forms for new construction and renovated structures within the DV districts defined in section 27-107B, districts. (b) Applicability. The provisions of this section shall only apply to improvements which involve one or more of the following: (1) New structure. Development of a new principal structure on a lot or portion of a lot; or (2) Expansions of existing structures. Redevelopment or expansion that results in an increase in existing building gross floor area on the subject property by more than ten percent, based on the total floor area added over the previous 12-month period. (c) Districts, building types. For each lot, a designated DV district is found on figure 27- 107B-1, regulating map. (1) District. Each district, per section 27- 107B, districts, has a set of requirements related to permitted building types, building height, site coverage, lot dimensions, setbacks, uses, and open spaces. (2) Building types. Each building type, as established in this section has a set of requirements. (3) Uses. Uses are permitted by district, per 27-107B(f), uses. Each building type can house a variety of uses depending on the district in which it is located. Some building types have additional limitations on permitted uses as located within the building. (4) Multiple principal structures. Multiple structures are permitted on all lots. All structures shall meet the requirements of one of the permitted building types for the district. (5) Permanent structures. All buildings constructed shall be permanent construction, unless otherwise noted. (6) Other structures. Utility structures and towers permitted in the district are exempt from the building type standards. (7) Build to the corner. a. The corner of the lot is defined as the intersection of the two build-to zones of each street. b. Buildings shall be built up to the corner along both adjoining streets, occupying the intersection of the two build-to zones of any intersection streets. Courtyards shall not be located in this area. (8) Treatment of build-to zones, setbacks. See section 27-621 terms defined for definition of build-to zones and setbacks. a. Landscape areas.All build-to zones and setbacks not containing authorized buildings shall only contain courtyards (as permitted by street type frontage), plazas (as permitted by street type frontage), patios (as permitted by street type frontage), sidewalk or path extensions, buffers, and/or landscape yards, unless otherwise specifically noted. (9) Driveways. a. Public works director. The public works director shall determine the need to close existing driveways, width of driveways, and proximity of driveways to other driveways or streets. b. Alleys/lanes. Access from an adjacent alley or lane is unlimited. Construction of new private or public alleys/lanes through blocks is encouraged. Typically, alleys or lanes cut through a block and provide vehicular access to multiple garages, parking lots, or service areas. c. Secondary street access. If no alley exists, one driveway access per 200 linear feet of street frontage or two total driveway access points, whichever is greater, are permitted from each secondary street per site. d. Driveway access. If no alley or secondary street exists, one driveway access point is permitted off each primary street. e. Shared driveways. Shared driveways are required for all adjacent developments. f. Inter-lot drives. When two or more parking lots are located adjacent to each other and each lot is within the same DV district, the parking lots shall be connected with a drive perpendicularly crossing the transition yard. Other parking lots should be connected wherever practical. g. Pedestrian facilities.At-grade, designated pedestrian routes, including sidewalks and crosswalks, shall be provided to connect each parking area to either the primary sidewalk (and front entrance) or a rear public entrance. 1. Vehicular areas, such as driveways, parking lot aisles, bike lanes/facilities, and parking areas, shall not be utilized as designated pedestrian routes. 2. Pedestrian connections are required between all adjacent sites and land uses. h. Driveway location. Driveways may cross perpendicularly through build-to zones and setbacks, or to connect to a parking lot on an abutting lot. (10) Loading facilities. a. Loading facilities may not face a primary street. b. Loading facilities may not be located in any required building setback area or within the build-to zone. c. The preferred location for loading facilities is in the interior of the lot, not visible from any streets. d. Loading facilities visible from a street must be screened from the sidewalk by a fence/wall or a combination of fence/wall and landscape screening. 1. Fence/wall. Fences and walls shall be no taller than six feet and shall have a minimum overall opacity of 80 percent. Materials must meet the requirements of section 27- 107D(d)(3)a, predominant exterior materials. 2. Landscape. Tree canopies shall be used to screen above the six-foot wall or fence. 3. Shrubs and hedges. Shrubs and hedges may be utilized to fulfill no more than one third of the screening, as measured along the screen length.A double row of five-gallon shrubs, with mature height of a minimum six feet, is required. (11) Accessory buildings. a. Attached accessory structures are considered part of the principal structure and shall meet all requirements of the principal structure. b. Detached accessory structures are not permitted between the face of the building and any public or private street right-of-way line. (d) Architectural standards. (1) Applicable façades. These standards shall apply to all façades visible from the street, facing streets, facing main parking lots, and adjacent to open spaces, unless otherwise noted. (2) Applicability. In addition to the applicability requirements of 27-107D(b), the provisions of this section shall apply to any alteration to an existing structure that includes renovation of more than 25 percent of an applicable façade. Work that includes maintenance and repair of the existing doors, windows, paint, and roofs does not apply. (3) Exterior materials. a. Predominant exterior materials.Predominant exterior finish materials are limited to: 1. Brick; 2. Unpainted natural stone; 3. Fiber cement siding; 4. Hard-coat stucco; or 5. Architectural ceramic panels. b. Secondary exterior materials. Secondary façade materials include all predominant materials. Other materials may be approved by the director of community development during the site plan review process. c. Accent materials. The following materials may be used for trim, details, soffits, eaves, and other accent areas: all predominant exterior materials, wood (including painted wood), synthetic materials, fiber cement, and aluminum or other durable metals. Other materials may be approved by the director of community development. d. Restrictions. The use of plain concrete block, aluminum siding, and vinyl siding are prohibited as façade materials. e. Roof materials. Acceptable roofing materials include asphalt shingles, wood shingles, reflective flat roofing systems, and other materials approved by the director of community development. Wherever asphalt shingles are used, they shall be a minimum three-dimensional architectural type. Standing seam metal roofs are permitted only as accents on porches or dormers. (4) Building façades. a. Façades shall provide front entrance(s) that are distinct and visible from the street, but should not exaggerate or double the height of the entrance. b. Simple massing is preferred and should be used with stoops, porches, galleries, arcades, roof eaves, and/or balconies to provide expressive character. c. Façades of all buildings with two or more stories shall provide a discernable base, middle, and cap that are clearly defined by horizontal elements along the bottom and top of the building. Expression of the elements should be handled through changes in material selection, color, or plane. Use of horizontal bands, cornices, and/or varied window patterns can assist in expression. d. Building wall materials may be combined on each façade only horizontally, with the lighter above more substantial materials. e. All glass shall be clear and free of color. f. Low pitch or flat roofs must be enclosed by a parapet that is a minimum of 42 inches in height, or a greater height as necessary to conceal mechanical equipment. g. Hardwood used for rafters, fascia boards, and all visible portions of roof decking shall be varnished, oiled, stained, or painted. Pressure treated wood shall be painted. (5) Awnings. All awnings must be canvas, glass, or metal. Plastic awnings are prohibited. Canvas and metal awnings may not be translucent. (6) Shutters. Where installed, shutters, whether functional or not, must be designed to the following standards: a. All shutters must be sized for the windows, so that if the shutters were to be closed, they would not be too small for complete coverage of the window. b. Shutters must be wood, metal, or fiber cement. Other "engineered" woods may be approved during the site plan review process with an approved sample and examples of successful, high quality local installations. (7) Garage doors. The following requirements apply to garage doors provided on any street façade: a. Location. Garage doors are not permitted on primary street façades unless not utilized for vehicular access (but may be used for patio access, open air dining, or similar purposes). Garage doors are permitted on secondary street façades with direct access to the street. The preferred location is on interior lot façades. b. Recessed from façades. Garage doors located on street facing façades shall be recessed a minimum of three feet from the dominant façade of the principal building facing the same street. c. Design. Garage doors facing a secondary street and intended to be closed during business hours shall be clad with materials consistent with the design of the building. Carriage-style doors are required on the townhouse building type. (8) Ground story at sloping façades. a. Intent. Given the topography in many parts of Dunwoody Village, building design must accommodate grade changes along the sidewalk without creating tall, out-ofscale blank walls. Large, unarticulated building façades signal to pedestrians that an area is not intended for walking, reducing activity in the area and creating dead zones. b. Regulations for shopfronts. 1. Grade transitions on the building along the sidewalk should be designed to maximize active pedestrian-scale frontages between waist and eye level while minimizing blank walls. 2. Unless impracticable, the interior floor level shall step to match the exterior grade. 3. If it is necessary for the interior floor to remain constant along the grade, changes may be accommodated by a storefront window display space. 4. Knee wall and retaining walls shall not exceed 30 inches in height except along a maximum 15-foot section of façade length. 5. If grade change is more than 12 feet along a single block face, entrance requirements may be increased to one entrance per 80 feet of building frontage. c. Regulations for residential and other building frontages. 1. Grade transitions at the building along the sidewalk should be designed to minimize blank walls. 2. Unless impracticable, the interior floor level should step to match the exterior grade. 3. Transition zones between the sidewalk and building façade of porches, terraces, and landscape areas may be used assist with grade changes. 4. If it is necessary for the interior floor to remain constant along the grade, changes can be accommodated by terraced planters and retaining walls. 5. Retaining walls shall not exceed 30 inches in height except along a maximum 15-foot section of frontage. 6. When the elevation of the first floor is more than three feet above grade, windows should be provided into the basement or lower floor elevations. (9) Multi-unit building balconies. All multiunit residential buildings, including those incorporating non-residential uses, shall incorporate balconies as follows: a. At least 50 percent of the dwelling units located on façades facing streets or façades adjacent to open spaces must provide private balconies. b. Required balconies must have a minimum depth of four feet and a minimum width of eight feet. c. Required balconies may be covered or uncovered. (e) Shopfront building regulations. (1) Intent. The shopfront building is intended for use as a mixed-use building located close to the sidewalk with parking in the rear or side of the lot. The most distinctive element of this building type is the ground floor front façade with large amounts of storefront glass and regularly spaced pedestrian entrances along the sidewalk, typically for retail and service uses. (2) Standards. The following are the regulations for shopfront buildings. (f) General building regulations. (1) Intent. The general building is intended to be built close to the sidewalk, but may also have a landscape yard. This building can be structured to house offices or residential uses including multi-family, and may have limited amounts of accessory retail and service uses in the ground floor. Parking is typically provided in structures at the rear of the lot, internally in the rear of the building, but may also have limited surface parking along the side of the building. (2) Standards. The following are the regulations for general buildings. (g) Townhouse building regulations. (1) Intent. The townhouse building is typically comprised of several multi-story attached house units, located adjacent to each other, each with its own pedestrian entrance to the street. (2) Standards. The following are the regulations for townhouse buildings. (h) Civic building regulations. (1) Intent. The civic building is the most flexible building type and is limited to civic and institutional types of uses. These buildings are distinctive within the village fabric created by the other building types and could be designed as iconic structures. (2) Standards. The following are the regulations for civic buildings. (i) Explanation of specific building type requirements. The following explains and further defines the standards outlined on the tables on the previous pages, specific to each building type. (1) Building siting. The following explains the line item requirements for each building type table within the section entitled "Building siting." a. Build-to zone coverage. The minimum percentage of building wall or façade along the street for each street is designated on each building type table. 1. Measurement.The width of the principal structures (as measured within the build-to zone along the frontage edge) is divided by the length of the frontage parallel to the property line following the street. 2. Courtyards. Courtyards, per section 27-621, terms defined, located along the façade in the build-to zone count towards the minimum coverage. Refer to street types for limitations of courtyards along some frontages. b. Build-to zone. 1. Defined. The build-to zone is the area on the lot where a certain percentage of the front building façade must be located, measured as a minimum and maximum yard (setback) range from the edge of the right-of-way. 2. Measurement. i. The percent of building façade in build-to zone specifies the amount of the front building façade that must be located in the build-to zone, based on the width of the streetfacing building façade divided by the width of the lot. The build-to zone is measured from the edge of the street frontage area onto the site. The lot width shall exclude any portions of the lot used for required transitions, provided new streets, or provided open space. ii. When a lot contains multiple buildings, the build-to zone requirements are measured as the sum of all buildings. There are no build-to zone requirements when a building is located behind another building that conforms to build-to zone requirements. Figure 27-107D-1 Build-to zone with allowed plaza (left) and on corner lot (right) 3. Open spaces. Outdoor open space, plazas, and outdoor dining areas are counted as part of the building for the purpose of measuring compliance with build-to zone requirements, provided that: i. The area does not exceed one-third the length of the building face or 35 feet, whichever is less; and ii. The area is no more than 35 feet in depth (refer to figure 27-107D-1). c. Corner lots. On corner lots, minimum requirements governing the percent of building façade that must be located in the build-to zone may be reduced by 60 percent along one of the frontages, at the property owner's option, provided that a building façade must be placed in the build-to zone for the first 30 feet along each street extending from the corner (refer to figure 27-107D1). 1. Encroachments. Awnings and building mounted signage may extend beyond the build-to zone into the frontage area, but may not extend into the street right-of-way. 2. Porches, arcades, galleries. Porches, arcades, and galleries may be included on the building façade design, utilizing the range of depth permitted by the build-to zone. If located outside the building coverage requirement, the depth of the arcade or gallery may exceed the build-to zone. (2) Floor-to-floor height. The following explains the line item requirements for each building type table within the section entitled "Floor-to-floor height." a. Overall permitted building heights are designated by district in stories. Refer to section 27-107B(b) through (e). b. Ground story, minimum and maximum height. (Refer to figure 27- 107D-2, measuring story height). Each building type provides a permitted range of height in feet for the ground story of the building. Figure 27-107D-2 Measuring Story Height 1. Taller spaces. Spaces exceeding the allowable floor-to-floor heights of the building type are not permitted on primary street façades. These spaces are unlimited on interior lot and other street façades. c. Ground story elevation. The allowable ground story elevation for each building type is defined, establishing whether or not a visible basement is permitted. 1. Visible basements. Visible basements, permitted by entrance type, are optional. The visible basement must not exceed one-half the height of the tallest story. (3) Uses within building. The following explains the line item requirements for each building type table within the section entitled "Uses within building." Refer to section 27-107B(f) uses for uses permitted within each DV district. The requirements in this section of the building type tables may limit those uses within a specific building type. a. Ground and upper story. The uses or category of uses which may occupy the ground and/or upper story of a building. b. Parking within building. The area(s) of a building in which parking is permitted within the structure. c. Required occupied space. The required depth of occupied space from the noted façade(s). Refer to section 27-621, terms defined, for the definition of occupied space. (4) Street façade design requirements. The following explains the line item requirements for each building type within the section entitled "street façade requirements". These requirements apply only to façades facing public or private streets and façades facing main parking lots where visitors or customers park. a. Minimum fenestration. (refer to figure 27-107D-4, measuring fenestration, per façade). Fenestration shall be measured as the percentage of the total façade area of each story dedicated to glazing. The following articulates the minimum amount of ground story transparent glass required on all façades facing streets. 1. Measurement. Ground story fenestration, when defined separately from the overall minimum fenestration, shall be measured as the percentage of the total façade area dedicated to glazing between two feet and ten feet above average grade at the base of the front façade. Refer to figure 27-107D-3, measuring ground story fenestration. 2. Transparent. Transparent means any glass in windows and/or doors, including any mullions, that is highly transparent with low reflectance. Glazed elements must be clear and non- reflective and not be painted or tinted, except that low-emission (Low-E) glass coatings are permitted. Figure 27-107D-3 Measuring Ground Story Fenestration Figure 27-107D-4 Measuring Fenestration per Façade 3. Other stories. A general minimum fenestration requirement applies to all other stories visible from any street. The fenestration is measured from top of the finished floor to the top of the finished floor above. When there is no floor above, upperstory fenestration is measured from the top of the finished floor to the top of the wall plate. 4. Arcades, galleries, courtyards. Ground story windows shall be located on the interior façade of any arcade or gallery. Ground story windows shall continue around a minimum of 60 percent of courtyard façades. b. Blank wall area. 1. Blank walls are areas on the exterior façade of a building that do not include a substantial material change; windows or doors; columns, pilasters or other articulation greater than 12 inches in depth. Blank wall limits are established in 27- 107D(e) through 27-107D(h). 2. Blank wall area regulations apply in both a vertical and horizontal direction. c. Entry area. Size requirements and recommended types of entrance areas per building type. d. Required number of street entrances. The minimum number of and maximum spacing between entrances on the ground floor building façade with street frontage. Street entrances for all non-residential uses shall remain unlocked during business hours. Entrances located on corners may satisfy the requirement of both adjacent streets. e. Vertical façade divisions. The use of a vertically oriented expression line or form to divide the façade into vertical divisions at increments no greater than the dimension shown, as measured along the base of the façade. Elements may include a column, pilaster, or other continuous vertical ornamentation a minimum of 1.5 inch depth. Refer to section 27-621, terms defined, for the definition of expression line. (5) Parking structures fronting a street. The following applies to parking structures fronting a public street, in addition to the requirements of 27-107C(c). a. Primary streets. Parking structures, whether accessory or principal use, shall not front a primary street, unless otherwise approved with special land use permit per article V, division 3. b. Parking structure design requirements. 1. Blank wall limitations. On any street façade, no rectangular area greater than 30 percent of any story's façade, as measured from floor to floor, and no horizontal segment of a story's façade greater than 15 feet in width may be solid, blank wall. 2. Pedestrian entry.A defined pedestrian entrance/exit is required separate from the vehicular entrance and directly accessing the sidewalk. If the entry is enclosed, 65 percent of the entry must be transparent glass. 3. Screening.All openings of any parking deck must be fully screened from view from any residential dwelling or adjacent public or private streets so that cars, sloped ramps, and interior deck lighting are not visible.