Sec. 27-250. Regulations.

About this text

  • As published by Municode, current through 2020-02-10
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Applicability.

(1) The regulations of this section apply:

a. To all new land uses, new developments and new buildings that require a permit;

b. Whenever existing land uses, developments or buildings are expanded by 25 percent or more in terms of additional dwelling units,

parking spaces or gross floor area, in which case the entire property must be brought into conformance with these regulations; and

c. whenever existing outdoor lighting constituting 60 percent or more of the permitted lumens for the parcel is modified or replaced, no matter the actual amount of lighting already on the site.

(2) When existing developments or buildings are expanded by less than 25 percent in terms of additional dwelling units, parking spaces or gross floor area and

the expansion requires a permit, the applicant must submit a complete inventory and site plan detailing all existing and any proposed new outdoor lighting.

Any new lighting on the site must comply with the shielding and lamp type regulations of this division.

(b) General regulations.

(1) Outdoor lighting fixtures must be full cutoff and placed so as to allow no light above the horizontal as measured at the

luminaire, except as herein noted in this section (as in the case of period fixtures, cutoff fixtures may be used) and except as allowed in chapter 20 of the Municipal Code (signs).

(2) Outdoor lighting fixtures must be located, aimed or shielded to minimize glare and stray light trespassing across

lot lines and into the public right-of-way.

(3) Flood or spot lamps must be positioned no higher than 45 degrees above straight down (half-way between the vertical and the horizontal) when the source is visible from any off-site residential property or public roadway.

At Property Lines Including Rights-of-Way Maximum Footcandles At property line abutting a residential or an agricultural use 0.5 At property line abutting an office or institutional use 1.0 At property line abutting a commercial or industrial use 1.5 Off-Street Parking Lots Minimum Footcandles Average Footcandles Maximum Footcandles Residential areas

0.5 2.5 4.0 Office-professional areas

1.0 3.5 6.0 Commercial areas

2.0 7.0 12.0 Light industrial areas

1.0 5.0 8.0

(4) All light fixtures that are required to be shielded shall be installed and maintained in such a manner that the shielding is effective as described herein for fully shielded fixtures.

(5) Lighting on sites consisting of multiple uses must conform to the standards of the respective uses.

(6) Illumination levels are measured from any height and orientation of the measuring device at any location along the property line except the lighting of parking lots must be measured at grade with the meter sensor held horizontally at the

surface.

(7) Color temperature of outdoor lighting fixtures must not exceed 3,000K at the light source except at outdoor sports,

recreation fields and performance areas.

(c) Specific uses and activities. This subsection establishes supplemental lighting regulations for specific types of uses and activities. All lighting not directly associated with the special

use areas designated below must comply with all other applicable regulations of this division.

(1) Outdoor sports, recreation fields and performance areas. Lighting of outdoor recreational facilities (public or private), such as, but not limited to, outdoor athletic

fields, courts, tracks, special event or show areas must comply with the following regulations:

a. Facilities designed for municipal leagues, elementary to high school levels of play and training fields for recreational or social levels of play, college play, semi-professional, professional or national levels of play must utilize luminaries with minimal

uplight consistent with the illumination constraints of the design.Where fully shielded fixtures are not utilized, acceptable luminaries include only those that:

1. Are provided with internal and/or external glare control louvers or lenses, and are installed so as to minimize uplight and offsite light trespass and glare, and

2. All lighting installations must be designed to achieve the illuminance levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA RP-6).

Light Trespass Limitations for Sports Lighting Environmental Zone Pre-Curfew Limit Post-Curfew Limit Degrees Above Nadir

(not to exceed 12,000 candela from a single fixture) E1 Not allowed 0.0 max vertical Not allowed E2 0.25 max horizontal

1.0 max vertical

0.10 max vertical 82 degrees E3 0.5 max horizontal

2.0 max vertical

0.30 max vertical 85 degrees E4 0.75 max horizontal

3.0 max vertical

0.60 max vertical 88 degrees E1 = Areas with intrinsically dark landscapes, such as national parks, areas of outstanding natural beauty, etc.

E2 = Areas of low ambient brightness, including sensitive residential areas.

E3 = Areas of medium ambient brightness, generally being urban residential areas.

E4 = Areas of high ambient brightness, which would include dense urban areas with mixed residential and commercial use with high levels of nighttime activity.

b. All events must be scheduled so as to complete all activity no later than 10:30 p.m. Illumination of the playing field, court or track is permitted after the curfew only to conclude a

scheduled event that was unable to conclude before the curfew due to unusual circumstances. Field lighting for these facilities must be turned off within 30 minutes of completion

of the last event of the night.

c. All light poles must be set back a minimum 60 feet from any residential property line or right-of-way.

(2) Service station canopies and parking garages.

a. All luminaries mounted on or recessed into the lower surface or service station canopies and parking structures must be fully shielded and utilize flat lenses.

b. The total light output of luminaries mounted on the lower surface, or recessed into the lower surface of the canopy, and any lighting within signage or illuminated panels over the pumps, may not exceed 50 footcandles. The total light output of other illuminated areas of a service station may not exceed 15 footcandles.

c. Illuminance levels for the interior of parking structures, where interior lighting is visible from outside the structure, must conform to IESNA recommendation RP-20.

d. Lights may not be mounted on the top or sides of a canopy, and the sides of the canopy may not be illuminated.

(3) Security lighting.

a. Security lighting must be directed towards the targeted area.

b. Sensor activated lighting must be located in such a manner as to prevent direct glare and lighting into properties of others or into a public right-of-way, and the system must be designed and maintained so that lights are not activated by activity off of the subject property.

(4) Pedestrian path lighting. Lighting posts for pedestrian path lighting may not exceed 16 feet in height from finished grade.

(5) Architectural accent lighting.

a. Fixtures used to accent architectural features, materials, colors, style of buildings, landscaping, or art must

be located, aimed and shielded so that light is directed only on those features. Such fixtures must be aimed or shielded to minimize light spill into the dark night sky in conformance with the luminaire standards.

b. Lighting fixtures may not generate glare, or direct light beyond the façade onto a neighboring property, streets or into the night sky.

(6) Temporary lighting permits. Permits for temporary lighting may be granted by the community development department if the total output from the luminaries does not exceed 50 footcandles, subject to the following regulations:

a. The lighting may not remain for more than 30 days, except that permits for a major construction project may extend to completion.

b. The lighting must be designed in such a manner as to minimize light trespass and glare.

c. Temporary recreational lighting allowed by permit must be extinguished by 10:30 p.m.

(7) Parking areas.

a. All lighting fixtures servicing parking lots must be directed downward and not towards buildings or other

areas.

b. Parking lots must be illuminated to a minimum illumination level of 0.4 footcandles at grade level, and the ratio of the average illumination to the minimum illumination may not exceed 4:1.

c. Light poles used in parking lots with 100 parking spaces or less may not exceed 20 feet in height. Light poles used in parking lots with more than 100 parking spaces may not exceed 35 feet in height.

(8) Street lights. Unless street light fixtures are of a period or architecture style as approved by the public works department, all new, repaired or replaced fixtures must be full cutoff fixtures.

History

The history line the source prints at the end of the section.

(Ord. No. 2013-10-15, § 1(Exh. A § 27-14.50), 10-14-2013; Ord. No. 2015-01-05, § 1, 1-26- 2015; Ord. No. 2022-06-10, § I, 6-13-2022)