Sec. 32-369. Maintenance requirements for new and existing FSE's.

About this text

  • As published by Municode, current through 2020-02-10
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Depth of FOG. The depth of FOG (floating and settled) in the FOG interceptor shall not be equal to or greater than 20 percent of the

total operating depth of the interceptor.

(b) General requirements for FOG interceptors. In order to maintain FOG interceptors, all food service establishments shall remove the

sludge, floating materials, solids, and wastewater, and shall scrape all excessive solids from the walls, floor, baffles, and all pipe work and

shall pump interior and exterior FOG interceptors dry as set forth in these regulations and as required by the terms and conditions of the

permit.

(1) FOG interceptors shall be kept free from any inflow/infiltration such as grit, rocks, gravel, sand, eating utensils, cigarettes, shells, towels, rags, etc., as such inflow reduces the effectiveness of the FOG interceptor; thereby increasing the need for more frequent cleaning.

(2) To ensure that the FOG interceptor can be maintained properly, the FOG interceptor needs to be free from any obstruction that would hinder the maintenance, function, and inspection of the interceptor.

(3) A state permitted transporter shall perform all maintenance of FOG interceptors. All state permitted transporters working in the city shall have an active state waste transporter's permit and a county

transporters permit in the manner and form set forth by O.C.G.A. § 12-15-20 et seq. Transporters working in the city are required to leave a copy of a nonhazardous waste manifest with the food service establishment. Maintenance schedules

may vary based on individual circumstances to protect the sewer system.

(4) The FOG compliance inspector has the authority to change the FOG interceptors cleaning cycles for any FOG generator at any time.

(5) The discharge or introduction of any additives to the sewer system is unlawful and prohibited. The direct introduction of

additives into the FOG interceptor is prohibited. Additives include, but are not limited to, biological agents such as enzymes, bacteria, and/or degreasing agents.

(6) The FOG generator shall be responsible for the proper removal and disposal of the FOG interceptor waste by a state permitted waste transporter and maintenance of records of disposal as specified in this section. All waste removed from each FOG interceptor must be disposed of at an appropriate disposal facility designed to receive such waste.

(7) No FOG interceptor pumpage shall be discharged to the sewer system as otherwise prohibited in these regulations.

(8) Every FOG interceptor shall be required to have a Georgia Nonhazardous Waste Manifest. The Georgia Nonhazardous Waste Manifest must be complete with all information required by these regulations and state law.

(9) Mechanical FOG interceptors are prohibited in the city.

(c) Exterior FOG interceptors. Maintenance of exterior FOG interceptors shall be performed at least once every 90 days. Skimming, decanting, and/or any reintroduction of water into exterior FOG interceptors shall not be allowed under any conditions.

(d) Interior FOG interceptors. Interior FOG interceptors maintenance shall be performed once every 30 days, and all of the fresh air and/or safe-way plumbing fixtures shall be connected. In-house cleaning of interior FOG interceptors is prohibited. To ensure proper FOG interceptor maintenance, interior FOG interceptors shall be free from any obstruction that would hinder the maintenance of the interceptor. Interior FOG interceptors shall be easily accessible with a minimum clearance of 36 inches.

(e) Interior and exterior FOG interceptor records. All food service establishments shall maintain records of the date and time of all cleaning and maintenance. Every FOG interceptor manifest shall be placed in a logbook, folder, or three-ring notebook. This book shall be made

available on demand by the FOG compliance inspector during inspection. All records of at least three years shall be kept on site and available. These records shall include:

(1) A logbook of FOG interceptor and/or FOG control device cleaning and maintenance;

(2) A record of best management practices being implemented, including employee training;

(3) Copies of records and manifests of waste transporting interceptor contents;

(4) Records of any spills and/or cleaning of the lateral sewer line; and

(5) Records of sampling data and sludge height monitoring for FOG and solids accumulation in the FOG interceptors.

History

The history line the source prints at the end of the section.

(Comp. Ords. 2008, ch. 25, art. III, div. 5.1, § 8)