(a) Clearing and grubbing right-of-way. This work shall consist of removing and disposing of all vegetation and debris within the right-of-way to a depth of at least three feet below the existing grade for any fill sections and three feet below finished sub grade for any cut sections.

Topsoil shall be stripped and stockpiled for later use. All stump holes shall be backfilled and compacted to 98 percent of the Standard Proctor density with a suitable material, class I or II material. All compaction tests and their associated costs, as described herein, shall be the responsibility of the contractor/developer.

(b) Subgrade. This work shall consist of placing, mixing, compacting and shaping the top six inches of soil. This work also includes subgrade stabilization. The subgrade shall be compacted to 98 percent of the Standard Proctor Density and tests shall be conducted at least once for every lift for every 500 feet of road. Proof-rolling of the entire area may be required consisting of a ten-ton payload on a standard tandem axle dump truck or other mutually agreed upon piece of loaded machinery.

(c) Base. All streets shall have a six-inch crusher run stone base or a four-inch compacted graded aggregate base (GAB) at 100 percent of the Standard Proctor density. Compaction testing intervals shall be as prescribed in subsection (b).

Proof-rolling may also be required per the same paragraph.

(d) Prime. All roadways shall be primed in accordance with DOT specifications.

(e) Paving.

(1) Residential/subdivision street. A one and one-half-inch plant mix asphalt type E or F top wearing surface is to be applied over a two and one-half-inch type B binder surface.

(2) Major rural and arterial roads. The minimum paving design for major rural and arterial roads shall be compacted subbase at 98 percent of the Standard Proctor density, a six-inch graded aggregate base, three inches of type B binder, and two inches of type E or F top wearing course. Accel/decel lanes or a center turn lane may be required if deemed necessary by the city/county engineer. (Note: DOT roads must meet DOT specifications/approval.)

(3) Driveway turnouts/curb cuts. These shall be paved in accordance with the applicable receiving street/road and shall have a minimum radius of 15 feet. Suitable concrete paving is also acceptable for turnouts or curb cuts. Turnout/curb cuts serving single driveways shall have a minimum width after radius of 12 feet with commercial/ industrial turnouts/curb cuts meeting sub-collector requirements of section 75-592.

(4) Commercial/industrial entrance and lots. Due to the American[s with] Disability [Disabilities] Act, any and all ingress, egress, and parking lots/area including internal roads to and from, shall be paved by suitable conventional asphalt paving or concrete paving.

History

The history line the source prints at the end of the section.

(Ord. of 3-20-2006)