A. The holder of a city permit issued pursuant to this division shall be required to perform such monitoring and recording of process and operational parameters as deemed necessary and appropriate by the city council or its designee. Monitored parameters and required measuring and recording frequencies may include, but are not limited to, one or more of the following:
As to incinerators.
Frequency and mass of waste charging (continuous).
Ash generation (weekly).
Primary and secondary chamber temperatures (continuous).
Flue gas opacity (weekly).
Auxiliary fuel usage (weekly).
Primary and secondary combustion air flow rates (weekly).
Fan motor current (weekly).
Wet scrubbers (weekly) including scrubber liquid header pressure; scrubber liquid flow rate; scrubber liquid pH (daily); scrubber static pressure drop; demister static pressure drop.
Dry scrubbers and spray dry absorbers, including reagent flow rate (daily); Slaker slurry outlet temperature (weekly); solids recycle rate (weekly); nozzle air and slurry pressures (weekly); wet and dry bulb temperature (weekly).
Fabric filters, including bag failure records (continuous); static pressure drop (weekly); baghouse inlet and outlet temperatures (weekly).
Flue gas concentrations of: acid gases, CO, O2, CO2, opacity.
As to autoclaves.
A recording thermometer shall be used each complete cycle to ensure the attainment of a temperature of 121 degrees Celsius (250 degrees Fahrenheit) for at least one-half hour in order to achieve decontamination of the entire load.
The steam sterilization process shall be monitored. Monitoring may be through the use of biological indicators or other methods as approved by the city council. Indicators used to ensure the attainment of the proper temperature during steam sterilization shall be placed at the point of the load where the rate of thermal penetration is at a minimum.
B. The permit holder shall perform Toxicity Characteristic Leaching Procedures, Method 1311, EPA Publication SW.846 (TCLP) analysis of the ash based upon a schedule and with such frequency as determined by the city council or its designee. This analysis may include grab samples and the analysis of composite grab.
C. The city council or its designee may require the permit holder to engage in performance testing of the medical waste incinerator, autoclave, or biomedical waste disposal facility at one or more of the following times: initial startup of a new facility, startup of an existing facility after significant modifi-cation or operational changes, prior to the issuance of an initial city permit and/or the renewal of an existing city permit. Said testing may include, but shall not be limited to, TCLP testing of ash, combustibility testing of ash, putrescibility testing of ash, stack testing for acid gases, metal, CO, VOCs dioxins/furans, PM, biologic tracer testing, temperature testing, and thermal penetration testing.
D. The permit holder shall be required to provide the city council or its designee and any applicable Bartow County agencies copies of all semi-annual reports the permit holder submitted to the EPD, all notices of violation issued by the EPD and the permit holder's responses thereto, EPD reports of no-notice site inspections, and all other correspondence with and submissions to the EPD. The permit holder shall also notify the city promptly of any serious occurrence likely to cause public concern such as fire, explosion or extensive uncontrolled emission.
E. Annually, the permit holder shall provide the city council or its designee the resumes of supervisory and management personnel responsible for operation of the biomedical waste incinerator facility, autoclave, or biomedical waste disposal facility and all records of training and certification of employees working at the biomedical waste incinerator facility, autoclave, or biomedical waste disposal facility.
F. The permit holder shall present to the city council or its designee an ash management plan or a decontaminated waste disposal plan in the case of autoclaves when initially applying for a permit and annually thereafter. Such plan shall include a description of the estimated quantity of ash or decontaminated biomedical waste to be disposed of during the upcoming year and the names, addresses, and telephone number of all landfills at which such ash or decontaminated biomedical waste will be disposed.
G. The city council or its designee shall have the right to inspect the biomedical waste incinerator or biomedical waste disposal facility during normal operating hours without prior notice to the owner/ operator of the facility. The right to inspect shall include the authority to perform independent testing on any aspect of the biomedical waste incinerator facility or the biomedical waste disposal facility for the purpose of ascertaining the owner/operator's compliance with the requirements of this division. The city council or its designee shall have the authority to require the facility's owner/operator to install auxiliary sampling ports as a condition of its permit for the purpose of supporting inspections and independent testing.