1. At least 50 percent of the building materials used for the total exterior facade must be brick or stone. Brick or stone materials shall wrap around at outside building corners of at least three feet height (water table). The remainder may be wood, hard-coat stucco, board and batten, fiber cement siding and cedar shakes. Vinyl siding and External Insulation and Finishing Systems (EIFS) are prohibited.
2. Garages are required for each townhome and home. Doors shall be architectural in style.
Standard panel doors are prohibited. Garage doors shall be recessed a minimum of 12 inches from the front faade.
3. Front facades for each townhome and home shall have at least one of the following: front porch, stoop, or balcony.
4. For townhomes, no more than six units can be attached.
5. For townhomes and homes, units should be designed to provide a variety of facades. This can be achieved by changes in brick/stone color and materials, projection or recess of architectural features, or varied rooflines. Dormers or gable pediments shall be incorporated into 25 percent of units.
6. Each residence shall have at least one window on all sides - at least one window on each side shall be minimum two feet in width by three feet in height.
7. Nonresidential development design. A metal panel exterior finish product shall not be allowed on metal buildings exceeding 150 square feet in gross floor area constructed or placed on lots within the PUD district, unless finished with a product consisting of brick, stone, hard-coat stucco, or other appropriate product as approved by the zoning administrator or his/her designee.
8. Refuse areas (dumpsters) shall be placed in the least visible location from public streets and shall be enclosed on three sides with opaque walls, with the fourth side being an opaque closing gate.
Height of an opaque wall shall be at least one foot higher than the receptacle.
9. All site lighting shall be directed onto the site.
10. At least three architectural plans and designs showing all four sides of proposed units or buildings shall be submitted to the zoning administrator for review prior to the issuance of building permits. The zoning administrator is authorized to approve alternative premium exterior finishes of comparable or superior quality and durability to brick or stone, provided such finishes maintain the intended character and design quality of the development. However, Vinyl siding and External Insulation and Finishing Systems (EIFS) remain prohibited.
11. The developer shall provide a landscape plan as part of the civil plans which includes native species trees, shrubs, and/or bushes showing and noting the types of landscaping, including type of ground cover to be used, in common spaces such as the amenities area, mail kiosk area, development entrance, etc. There shall be a required minimum 25 feet wide landscape strip along all existing public road frontages that shall be separate from residential lots. The landscape plan shall show and note at least one tree and bush for each residential lot or unit.
12. This section shall apply to any development that has not obtained a Land Disturbance Permit at the time of adoption of this article.
History
(Ord. No. 2025-012, § 1A, 9-8-2025; Ord. No. 2025-023, § 1B, 12-8-2025)