(a) Purpose. The purpose of this section is to establish reasonable and uniform regulations for the location, installation, operation and maintenance of solar energy systems, to assure that the development and production of solar energy systems is safe and to minimize any potentially adverse effects on the community; to promote the supply of sustainable and renewable energy sources, in support of national, state and local goals; and to facilitate energy cost savings and economic opportunities for individuals and businesses situated within the City of Fairburn.

(b) Solar energy system general regulations.

Building mounted, building integrated, flush mounted and ground mounted solar energy

systems may be erected or installed on properties used or zoned for residential or nonresidential purposes, and in accordance with this article and electric service ordinances, all state and federal laws and regulations as amended from time to time, concerning its use and operation and shall be further subjected to the following standards:

(1) Shall only be permitted if accessory to a principal building/use.

(2) Shall be installed according to manufacturer specifications and in accordance with all applicable city ordinances.

(3) No solar energy system shall be mounted or affixed to any freestanding wall or

fence.

(4) Electric solar energy system components must have a UL listing.

(5) An external disconnect switch, readily accessible by city emergency personnel,

and which is clearly identifiable and unobstructed, shall be provided to disconnect power at the solar panel.

(6) Labels indicating the use of solar panels shall be posted at an easily viewable

location. The label shall clearly state the name, address and phone number of the

person or persons authorized to deactivate the solar system in the event of an

emergency. In addition, the label shall contain the words "WARNING: PHOTOVOLTAIC POWER SOURCE". Labels shall be placed adjacent to the main

service disconnect switch in a location clearly visible from the location where the disconnect switch is operated.

(7) Utility notification. No interconnected distributed generation system, including photovoltaic systems, shall be installed until evidence has been given to the

planning and zoning department that the owner has submitted the required contracts and agreements to the city pursuant to chapter 59, utilities, article V, Electric service, section 59-113,

Distributed generation. Non-interconnected distributed generation systems are exempt from this requirement.

(8) The fire department shall review and comment on the installation of solar collectors that are building mounted to verify that adequate roof access is provided to emergency personnel in the case of an

emergency.

(9) Glare and lighting.

a. The solar energy components shall be designed and installed with an antireflective coating or at least shall not produce glare that would

constitute a nuisance to occupants of neighboring properties, aircraft, or persons traveling on adjacent or nearby roads.

b. If lighting is required, it shall be activated by motion sensors, fully shielded and downcast type where the light does not spill onto any adjacent property or into the night sky.

(10) Noise. Inverter noise shall not exceed 40 dBA, measured at the property line.

(11) Maintenance, upkeep and decommissioning:

a. Systems shall be maintained in accordance with manufacturer's specifications. The operator of the facility shall maintain the facility, including all buffer screening, in compliance with the approved plans and shall keep the facility free from weeds, dust, trash and debris.

b. Systems shall be considered obsolete or unused when they have not been operated for 12 consecutive months.

All obsolete or unused systems shall be repaired or removed at the owner's expense. If the owner fails to remove or repair the defective or abandoned solar energy system, the City of Fairburn may pursue a legal action to have the system removed at the owner's expense, including but not limited to the issuance of a citation for violation of this section, whereby the owner will be required to appear before the municipal court of the City of Fairburn.

(12) This section shall not apply to a noninterconnected distributed generation systems/self-contained solar energy

systems; however, non-interconnected distributed generation system/selfcontained solar energy system(s) shall comply with the following restrictions:

a. On property used or zoned for residential or non-residential purposes, non-interconnected distributed generation systems/selfcontained solar energy systems that are ground mounted are limited to

an aggregate solar collector surface area less than or equal to six square feet.

b. On property used or zoned for residential purposes, non-interconnected distributed generation system/self-contained solar energy

systems that are building mounted are limited to an aggregate solar collector surface area less than or equal to six square feet.

(13) Any additional information and data reasonably necessary to evaluate the

conformity of the solar energy system with this article pursuant to the request of the zoning administrator.

(c) Building mounted solar energy system requirements. Building mounted solar energy systems may be allowed on property that meets all requirements as defined in the section below and elsewhere in this article.

(1) Type permitted and roof area maximum.

a. On property used or zoned for residential purposes:

1. Building integrated and/or flush mounted small solar energy systems are permitted to be installed on any roof area.

2. Non-flush mounted small solar energy systems are not permitted on a building with a flat roof.

3. Non-flush mounted small solar energy systems shall only be permitted on the back roof or side roof and shall not exceed the highest point of the roof line or pitch so it remains completely screened from view to an observer on the street.

4. A non-flush mounted small solar energy system is prohibited on any roof that is adjacent to the front yard and/or corner side yard.

5. The solar collector surface area shall not cover more than 80 percent of any roof area upon which the collectors are mounted, and shall be set back from the roof edge by a minimum of one foot.

b. On property used or zoned for nonresidential purposes:

1. Building integrated and/or flush mounted small or large solar energy systems are permitted to be installed on any roof area.

2. Non-flush mounted small or large solar energy systems are permitted on a building with a flat roof if the solar collector is completely screened from view to an observer five feet above the ground at any point along an abutting property line.

3. Non-flush mounted small or large solar energy systems are permitted on a building with a pitched roof but shall only be permitted on the back roof or side roof and shall not exceed the height of the highest point of the roof line or pitch so it is completely screened from view to an observer five feet above the ground at any point along the street view.

4. Non-flush mounted small or large solar energy system is prohibited on any pitched roof that is adjacent to the front yard and/or corner side yard.

5. The solar collector surface area shall not cover more than 80 percent of any roof area upon which the collectors are mounted, and shall be set back from the roof edge by a minimum of one foot.

(2) Maximum permitted height and building projection/extension.

a. On property used or zoned for residential purposes:

1. Non flush-mounted small solar energy systems shall not extend above the highest point of the roof line.

2. Shall not project/extend beyond the exterior wall of any building on which the system is mounted or built.

b. On property used or zoned for nonresidential purposes:

1. Non flush-mounted small or large solar energy systems shall not extend above the highest point of the roof line or a parapet wall.

2. Building integrated and/or flush mounted small or large solar energy systems shall not extend two feet above the roof and shall not extend beyond the highest point of the roof.

3. Shall not project/extend beyond the exterior wall of any building on which the system is mounted or built.

(d) Ground mounted solar energy system requirements. Ground mounted small solar energy systems may be allowed on property used or zoned for residential purposes and ground mounted small or large solar energy systems may be allowed on property used or zoned for non-residential purposes. A ground mounted solar energy system shall meet the requirements as defined in the section below and elsewhere in this article:

(1) Site plan review. Small or large ground mounted solar energy systems proposed

within residential zoning or nonresidential zoning districts shall undergo site plan review prior to construction, installation or modification. The following must be

shown on the site plan:

a. Property lines and physical features, including roads, for the project site;

b. Proposed changes to the landscape of the site, grading plan, vegetation clearing and planting plan, exterior lighting, screening vegetation or structures;

c. Blueprints or drawings of the solar energy system showing the proposed layout of the system, any potential shading from nearby structures, the distance between the proposed solar collector and all property lines and existing on-site buildings and structures, and the tallest finished height of the solar collector;

d. Documentation of the major system components to be used, including the panels, mounting system, and inverter;

e. Name, address, and contact information for proposed system installer;

f. Name, address, phone number and signature of the project proponent, as well as all co-proponents or property owners, if any;

g. The name, contact information and signature of any agents representing the project proponent; and

h. Zoning district designation for the parcel(s) of land comprising the project site. Erosion and sedimentation plan, if applicable.

(2) Maximum height. On property zoned for residential or non-residential purposes:

a. Shall not exceed 25 percent of the footprint of the principal building served for residential properties, nor more than 50 percent of the footprint of the principal building served for non-residential properties.

b. Shall not exceed ten feet in height for non-residential property and five feet in height for residential property, unless the solar collector is attached

to a legal and conforming parking lot light pole or other monopole structure that is necessary to the lot.

c. When a solar collector is attached to a legal and conforming parking lot

light pole or other permitted monopole structure that is an accessory to the lot, the solar collector shall not extend more than five feet

above the height of the parking lot light pole or other monopole structure.

(3) Location requirements. On property used or zoned for residential or non-residential purposes:

a. Shall be set back a distance not less than or equal to one times the system

height or five feet, whichever is greater, measured from the edge of the system to the nearest property line. However, a solar collector attached to a legal and conforming parking lot light pole or other permitted monopole structure that is accessory to the lot may have a setback less than five feet.

b. On property that is zoned for residential purposes, no part of a ground mounted system shall be located in the front yard or corner side yard.

c. A solar collector may only be attached to a legal and conforming parking lot light pole or other permitted monopole structure if all other ordinance requirements are met.

d. No part of a ground mounted system shall be located or protrude into a dedicated easement.

e. A ground-mounted system shall not be located over a septic system, leach field area or identified reserve area unless approved by the health department.

f. If located in a floodplain or an area of known localized flooding, all

panels, electrical wiring, automatic transfer switches, inverters, etc. shall be located above the base flood elevation.

g. All transmission wiring installed between the solar system and the premise being served shall be installed underground.

h. It is the property owner's responsibility to obtain any solar access easements he/she deems necessary to secure the right to receive sunlight

across real property of another for continued access to sunlight necessary to operate a solar energy system.

i. A landscape buffer shall be provided around all ground mounted solar energy systems including but not limited to its mechanical equipment and solar panels to provide screening from adjacent properties and shall consist of a variety of native,

drought-resistant evergreen plants.

Such screening shall be a height at the time of planting equal to the maximum height of any part of the ground mounted solar energy systems. The landscape buffer shall remain undisturbed except as required to implement landscape enhancements. Buffers shall be well maintained. Buffer requirements may be expanded where circumstances of topography or other factors render normal buffers ineffective. All buffers shall be subject to the approval of the zoning

administrator.

(e) Variance. The planning and zoning commission shall be allowed to grant variances where a hardship has been demonstrated pursuant to section 80-251 of this Code.

History

The history line the source prints at the end of the section.

(Ord. of 5-22-2017(1), § 1(Exh. A)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:fairburn/zoning/80-496@2026-11-11-7692f846db

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Fairburn Zoning Ordinance, Sec. 80-496. Solar energy systems | Georgia Commons