--- title: Fayette County Zoning Ordinance, Sec. 104-153. Tree retention, protection and replacement requirements collection: local-codes id: local-code:fayette-county/zoning/104-153 cite_as: Fayette County, Ga., Zoning Ordinance § 104-153 canonical_url: https://georgiacommons.org/code/local/fayette-county/zoning/104-153 md_url: https://georgiacommons.org/code/local/fayette-county/zoning/104-153.md text_url: https://georgiacommons.org/code/local/fayette-county/zoning/104-153/text source_url: https://library.municode.com/ga/fayette_county/codes/code_of_ordinances date: 2026-05-28 status: active jurisdiction: county:fayette jurisdiction_name: Fayette County county_fips: "13113" corpus_version: local-codes-fayette-county-a7a551bedadd publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/fayette-county/zoning/~part-ii/~part-b/~chapter-104/~article-vi.md previous: https://georgiacommons.org/code/local/fayette-county/zoning/104-152.md next: https://georgiacommons.org/code/local/fayette-county/zoning/104-154.md index: https://georgiacommons.org/code/local/fayette-county.md branch: zoning edition: As published by Municode, current through 2026-05-28 edition_date_kind: current_through source_publisher: Municode version_id: local-code:fayette-county/zoning/104-153@2026-05-28-260995fb9c --- # Fayette County Zoning Ordinance, Sec. 104-153. Tree retention, protection and replacement requirements > As published by Municode, current through 2026-05-28 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. > Read by OCR from a scanned page: a character, a name, or a number may be misread. Part of: Part II - COUNTY CODE / Part B - LAND DEVELOPMENT AND LAND USE / Chapter 104 - DEVELOPMENT REGULATIONS / Article VI - TREE RETENTION, PROTECTION AND REPLACEMENT For all sites with three acres or less, all trees used in the SDU calculation shall be individually inventoried. For all sites over three acres industry standard sampling methods may be used to prepare a tree survey when trees are of such density to make individual tree identification impractical. In such cases the tree surveyor shall show tree stands and provide estimates of size and species on the tree protection plan. (1) Site density requirements. The required tree density for each nonresidential site is referred to as the site density unit (SDU). Each property subject to this article shall have a minimum required SDU based on total number of disturbed acres on the project site. a. The total SDU required equals existing density units (EDU) plus replacement density units (RDU). b. Property subject to this article that is greater than or equal to three acres shall have or exceed an average SDU of 100 TDUs per acre. c. Property subject to this article that is less than three acres shall have or exceed an average SDU of 50 TDUs per acre. d. Credit will be given to trees retained on a property having a DBH of four inches or more. e. At least 50 percent of the EDUs per acre must be located outside of any zoning or watershed protection buffers as referenced in articles V and VII of this chapter. f. Palm trees are not acceptable for SDU credit. (2) Specimen trees. a. Criteria for determination of specimen trees or stands are as follows: 1. Any deciduous canopy tree whose DBH equals or exceeds 24 inches. 2. Any evergreen canopy tree whose DBH equals or exceeds 30 inches. 3. Any understory tree whose DBH equals or exceeds ten inches. 4. Any tree which has significant historical value and can be documented through historical records or otherwise. b. Removal. Any specimen tree removed without prior approval of the environmental management department will be replaced by trees equaling two times an inch-for inch replacement of the tree removed. Size alone will determine whether a tree was of specimen quality if the tree is removed without approval and there is no evidence of its condition. Such action may result in a stop work order issued by the environmental management department. c. Written justification must be given for any specimen tree designated for removal. The county environmental management department may require additional information including, but not limited to, a certified arborist's appraisal of the tree's viability and anticipated life span. d. Any specimen tree may be removed if it is shown that at least one of the following conditions is met: 1. The location of the tree prevents the opening of reasonable and necessary vehicular traffic lanes. 2. The location of the tree prevents the construction of utility lines or drainage facilities which may not feasibly be relocated. 3. The location of the tree prevents reasonable access to the property, if no alternate exists. 4. The tree is diseased, dead, or dying to the point that repair or restoration is not practical or the disease may be transmitted to other trees. 5. here is no reasonable assurance that if the tree is saved with proper construction precautions, it will continue to live as an asset to the site. e. Preservation. All reasonable efforts should be made to preserve specimen trees and incorporate them into the design of the project. Specimen trees saved by a specifically designed feature of the building, hardscape, or utilities shall be given EDU credit of two inches per inch of DBH. (3) Replacement tree requirements. All trees selected for replacement density units must meet the following requirements: a. Trees must be free of disease, injury, or infestation, and must be ecologically compatible with the specifically intended growing area, and planted in accordance with standards established by the international society of arboriculture. b. At a minimum, four species mixture of different trees, with at least three being deciduous hardwoods should be utilized. c. No more than 30 percent of replacement trees may be of a single species. d. A 50 percent mix of overstory and understory trees shall be maintained. e. Trees shall have a minimum caliper requirement of 2� inches in diameter as measured at six inches above the ground at time of planting. f. All trees planted to fulfill the replacement tree requirements shall be in place before a certificate of occupancy is granted. In the event that the requirements of this article cannot be met at the time a certificate of occupancy is otherwise granted, refer to �buffer and landscape areas,� section 104-117 performance surety, in these development regulations. g. All trees planted under the requirements of this article which do not survive for 24 months after issuance of a certificate of occupancy will be replaced as a condition of occupancy. Trees shall be bonded via a maintenance agreement in the amount of 100 percent of their replacement cost. Bonds will be released after the 24-month period has passed, and the health of the trees have been certified and accepted by the county. Refer to section 104-118, pertaining to general maintenance. h. See sections 104-115(d)(2) and 104-116 for suggested tree species. For additional tree species, especially understory (small) trees, see University of Georgia Cooperative Extension Service Bulletin No. 625 Landscape Plants for Georgia. § 104-153 (4) Tree protection requirements. a. A tree protection area shall be maintained around all trees and stands of trees to be retained throughout the duration of construction by tree protection fencing. The tree protection area of stand-alone trees and stands of trees shall be marked with standard tree protection fencing (orange), chainlink fenc-ing, stakes, and/or continuous engineering tape and "Tree Protection Area" signs. At least two "Tree Protection Area" signs shall be posted at each individual tree protection area. All tree protection fencing shall be inspected for proper installation by the environmental management department during the initial erosion and sediment control inspection. During subdivision street construction, land disturbance allowed by a development permit shall be limited to areas needed for street right-of-way, drainage easements, erosion and sediment control practices and utilities. All other areas shall remain undisturbed for tree protection purposes. If utilities must run through the tree protection area and the running of those utilities will encroach into the critical root zone CRZ of any trees to be saved, the utility must be tunneled at a depth of 24 inches. When feasible, utilities will run along streets, roadways, driveways, or sidewalks. Reasonable efforts shall be made to save as many trees as possible. If it is determined that irreparable damage has occurred to a tree or trees within a designated tree protection area, as determined by the county environmental management department, the state forestry commission, or a certified arborist, it shall be the responsibility of the developer/builder to remove and replace the tree or trees and guarantee survival after the issuance of the certificate of occupancy as references in subsection (3)(g) of this section and article V of this chapter. (5) Tree protection plan. a. Procedures. 1. The TPP shall be submitted with the preliminary plat, erosion, sedimentation and pollution control plan or the site plan, whichever is the first submittal required by the county planning and zoning department. 2. The tree protection plan shall be prepared by either a licensed landscape architect or forester, certified arborist, or other licensed professional of similar design discipline licensed in the state. The environmental management department shall have a maximum of 14 calendar days from the submittal date, or each resubmittal date, for plan review. If the plan is not approved a deficiency checklist will be submitted back to the applicant. Submittal. The tree protection plan shall be submitted on a scale of no less than one inch to 100 feet and shall include project name, design professional's name and contact information, north arrow, graphic scale, and date. The plan should clearly show and label the following: 1. 10. Tree save areas noting the location, size, DBH, dripline, CRZ, and species name (common name) of each tree that will be retained to fulfill the SDU requirements. Five or more trees whose dripline and CRZ combine into one tree protection area may be outlined as a group with the exception of specimen trees. Summary table listing the DBH and species name of each RDU and EDU tree used to obtain the required SDU under "Notes." If a group of trees is outlined on the plan as a tree save area, include a summary table listing the size, DBH and species name of each tree within that group under "Notes." Location of all new replacement trees including species name and DBH that fulfill RDU requirements. Location of any specimen tree designated in a tree protection area including the DBH, CRZ and species name even if contained in a group. If construction is limited to streets, drainage easements and utilities the TPP only needs to show all specimen trees located within 100 feet of the centerline of any right-of-way, or drainage/ utility easements. Location of any specimen trees designated for removal during construction including the size, DBH and species name. Location, depth and height of all existing and proposed utility lines. Boundaries of property, buffer and landscaped areas, buildings and structures, vehicle use areas, and other impervious areas. Calculations for meeting all required site density units under "notes." If a scientific method is used to determine the site density units, label all sample areas and provide estimates of trees by size and species as based on sampling method requirements. Under "notes" state the following: "No land disturbance, construc-tion processes, or storage of equipment or materials shall take place within a designated tree protection area in order to prevent direct physical root damage that occurs during site clearing and grading and can cause transport or feeder roots to be cut, torn, or removed; indirect root damage caused from grade changes; and trunk and crown damage caused by direct contact with land clearing machinery or galling of adjacent trees.� (Code 1992, § 8-179; Ord. No. 2000-02, 1-27-2000; Ord. No. 2012-02, § 1, 3-22-2012; Ord. No. 2012-12, § 1, 12-13-2012; Ord. No. 2016-13, § 5, 7-28-2016)