--- title: Fayette County Zoning Ordinance, Sec. 110-174. Historic district overlay zone collection: local-codes id: local-code:fayette-county/zoning/110-174 cite_as: Fayette County, Ga., Zoning Ordinance § 110-174 canonical_url: https://georgiacommons.org/code/local/fayette-county/zoning/110-174 md_url: https://georgiacommons.org/code/local/fayette-county/zoning/110-174.md text_url: https://georgiacommons.org/code/local/fayette-county/zoning/110-174/text source_url: https://library.municode.com/ga/fayette_county/codes/code_of_ordinances date: 2026-05-28 status: active jurisdiction: county:fayette jurisdiction_name: Fayette County county_fips: "13113" corpus_version: local-codes-fayette-county-a7a551bedadd publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/fayette-county/zoning/~part-ii/~part-b/~chapter-110/~article-v.md previous: https://georgiacommons.org/code/local/fayette-county/zoning/110-173.md next: https://georgiacommons.org/code/local/fayette-county/zoning/110-175.md index: https://georgiacommons.org/code/local/fayette-county.md branch: zoning edition: As published by Municode, current through 2026-05-28 edition_date_kind: current_through source_publisher: Municode version_id: local-code:fayette-county/zoning/110-174@2026-05-28-d02e066047 --- # Fayette County Zoning Ordinance, Sec. 110-174. Historic district overlay zone > As published by Municode, current through 2026-05-28 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - COUNTY CODE / Part B - LAND DEVELOPMENT AND LAND USE / Chapter 110 - ZONING / Article V - CONDITIONAL USES, NONCONFORMANCES, AND TRANSPORTATION CORRIDOR OVERLAY ZONE Starr's Mill Historic District Overlay Zone at the SR 74, SR 85, & Padgett Road Intersection. All property and/or development located at this intersection with nonresidential use or zoning as depicted on the Future Land Use Map shall be subject to the following regulations, in addition to the zoning district requirements, and other development regulations as applicable. The General State Route Overlay Zone shall not apply to this area. (1) The purpose of the Starr's Mill Historic Overlay Zone at the SR 74, SR 85, and Padgett Road Intersection is to achieve the following: a. To maintain the historic character of the area; b. To control the intensity and aesthetic quality of development at the intersection as it is the southern gateway into Fayette County; c. To promote and maintain orderly development for an efficient traffic flow in highway corridors; and d. To protect existing and future residential areas outside of the intersection. (2) Access. Access to each nonresidential property and/or development shall be from SR 74, SR 85, or Padgett Road. All access points shall be required to comply with Georgia Department of Transportation regulations and/or Fayette County Development Regulations, as applicable. (3) Dimensional Requirements. a. All parking areas shall be located at least 50 feet from SR 74, SR 85, or Padgett Road right-of-way. b. Front yard setbacks on SR 74, SR 85, and Padgett Road for all structures, including gasoline canopies, shall be 100 feet. c. Berms for nonresidential zoning districts: Berms when required as a condition of zoning, shall be a minimum of four (4) feet in height, and shall be placed to the inside of the applicable buffer. d. If the side yard abuts a nonresidential zoning district, all non-structural improvements, other than approved access, shall be located a minimum of 10 feet from the side property line. (4) Architectural Forms and Standards. All new structures shall maintain the historical and aesthetic character of the area. Starr's Mill was built in the late 1800s and is a significant historic resource in Fayette County. Starr's Mill is indicative of turn of the century architectural character common in rural areas and is a building of influence in this area. Other architectural styles such as One-Part Commercial Block and Two-Part Commercial Block associated with this period are acceptable for this overlay zone. Architectural examples are on file in the Planning and Zoning Department. Architectural Review. An owner/developer may obtain an administrative staff approval for structures by submitting elevation drawings denoting compliance with these architectural forms and standards. Staff review and approval will take place as part of the site plan approval process. An owner/developer may exercise an architectural review option for structures within the overlay zone. The purpose of this option is to allow the owner/developer to present a creative interpretation of the architectural intent of the overlay zone. Elevation drawings, submitted as part of the site plan approval process, shall be reviewed and considered by the Board of Commissioners in a public meeting with a recommendation from the Planning Commission and Staff. a. Starr's Mill: Starr's Mill is a two-story structure with a gable roof. The roof is corrugated metal. The façade is wood clapboard siding and runs in a horizontal pattern. The structure sits on a stacked stone foundation and stacked stone pillars. Windows are wood-framed with a grid muntin pattern. Doors are also wood-framed. The structure has a covered porch with stairs and a wood picket rail banister. The building is red, the stairs, porch framing and banisters are white, the stair landings and porch decking are grey and the roof and porch covering is a grey corrugated metal. 1. Roof: Gable roof with a minimum pitch of 4 )inches in one foot. Roofing material shall be grey corrugated metal. 2. Façade Material: Clapboard siding running in a horizontal pattern on all walls. Acceptable sidings include wood and fiber-cement siding (e.g., Hardiplank). The foundation shall have the appearance of stacked stone. Façade colors shall match with the color palette on file in the Planning and Zoning Department. 3. Doors and Windows: Doors and windows shall have a frame and grid muntin pattern as established by Starr's Mill. Door and window frames shall be white with a minimum width of four inches. Large display windows and glass doors shall give the appearance of grid pattern muntins and framing consistent with Starr's Mill. Grid pattern muntins shall be white. Large display or storefront windows shall have a minimum two-foot high bulkhead consistent with the Façade Materials above. 4. Covered Entrance: Covered entrances shall be in character with the Starr's Mill porch consisting of a grey corrugated metal matching the roof of the main structure. A white wood picket rail banister with a minimum height of three feet shall extend the full length of the covered entrance with a maximum entrance space of three feet. All support structures shall be white. b. One-Part Commercial Block: A popular commercial design from the mid-19th to the early 20th century. The one-part commercial block is a simple, one-story box with a flat or shed roof. Common façade materials consist of brick with decorative block, stone, and concrete accents. The focal point of the front façade is the entrance and windows, consisting of a recessed doorway and display windows with a transom resting on a bulkhead (the lower panels on which the windows rest) framed by pilasters. Architectural features include a cornice, belt course and parapet wall. 1. Façade Material: Brick/brick veneer shall be utilized on all walls as the primary façade material comprising a minimum of 65 percent of the wall, excluding doors, windows and associated framing. The brick color shall match with one of the colors in the brick palette on file in the Planning and Zoning Department. Painted brick shall not be allowed. The remaining 35 percent of the wall may have the appearance of a contrasting brick color, rough face decorative block, stone, and/or concrete accents and the colors shall match with the color palette on file in the Planning and Zoning Department. 2. Entrance Doors and Windows: The entrance door and window component shall consist of entrance door(s), display windows, door and window transoms, and bulkhead. Door and window frames may be constructed with wood, metal, or vinyl. An anodized silver finish shall not be allowed for door and window frames and all colors shall match with the color palette on file in the Planning and Zoning Department. Transoms shall be a minimum of two feet high and shall be separated from the windows and door by a mullion width of four inches. A minimum two-foot high bulkhead consistent with the Façade Materials above shall be required. 3. Architectural Features: A cornice is required. The cornice shall be a minimum of one foot in height with a minimum projection of four inches from the main façade. The projection may be gradual. A parapet wall is required along the front and side walls of the structure and shall be a minimum of two feet in height. Colors shall match with the color palette on file in the Planning and Zoning Department. c. Two-Part Commercial Block: A popular commercial design from the mid-19th to the early 20th century. These buildings have two primary components — first floor storefronts (similar in design to a One-Part Commercial Block) and upper floors which historically were used for residential or office space. The focal point of the first floor is the entrance and windows, consisting of a recessed doorway and display windows with a transom resting on a bulkhead (the lower panels on which the windows rest) framed by pilasters. Upper floors have one or more floors of smaller symmetrically-positioned windows. Architectural features include a cornice, belt course and parapet wall. Common façade materials consist of brick with decorative block, stone, and concrete accents. 1. Façade Materials: Brick/brick veneer shall be utilized on all walls as the primary façade material comprising a minimum of 65 percent of the wall, excluding doors, windows and associated framing. The brick color shall match with one of the colors in the brick palette on file in the Planning and Zoning Department. Painted brick shall not be allowed. The remaining 35 percent of the wall may have the appearance of a contrasting brick color, rough face decorative block, stone, and/or concrete accents and the colors shall match with the color palette on file in the Planning and Zoning Department. 2. Entrance Doors and Windows (first floor storefronts): The entrance door and window component shall consist of entrance door(s), display windows, door and window transoms, and bulkhead. Door and window frames may be constructed with wood, metal, or vinyl, An anodized silver finish shall not be allowed for door and window frames and all colors shall match with the color palette on file in the Planning and Zoning Department. Transoms shall be a minimum of two feet high and shall be separated from the windows and door by a mullion with a minimum width of four inches. A minimum two-foot high bulkhead consistent with the Façade Materials above shall be required. 3. Upper Floor Windows: Upper floor windows shall be symmetrically positioned. All window frames shall match with the color palette on file in the Planning and Zoning Department. 4. Architectural Features: A cornice is required. The cornice shall be a minimum of one foot in height with a minimum projection of four inches from the main façade. The projection may be gradual. A belt course with a minimum projection of one inch from the main façade shall be required between the first floor and the second floor. A parapet wall is required and shall be a minimum of two feet in height. Colors shall match with the color palette on file in the Planning and Zoning Department. d. Lighting: 1. All wall lighting shall consist of period lantern or goose neck pendant lighting. These restrictions shall not apply to wall lighting required by the Fire Marshal. 2. All pole lighting shall consist of period post top globe, lantern, or pendant luminaries with rapid-ship posts. e. Within the 50-foot front landscape area, a wall or fence is required to run along a minimum of forty (40%) percent of the frontage. If a wall, the wall shall be a minimum of three (3) feet in height with the appearance of stacked stone. If a fence, the fence shall be a minimum of four (4) feet in height with the appearance of wrought iron, picket, split rail or horse rail fence. Fence materials are limited to metal, vinyl/plastic, pre-cast concrete and masonry for columns. f. Color Palette: Only those colors indicated on the color palette on file in the Planning and Zoning Department shall be allowed for structures. Any changes to the color of structures in this overlay must be submitted to Staff for approval. g. The design of ancillary buildings and sign structures shall be consistent with the architectural style and color inherent in the principal structure on the property. (5) Landscape requirements. In addition to the standard requirements of the landscape ordinance, the following landscape requirements shall apply to the Overlay Zone: a. Street Frontage: Landscape area: Fifty (50) feet along the right-of-way of SR 74, SR 85, and Padgett Road. The first 25 feet as measured from the right-of-way is for required landscape planting only. The remaining 25 feet may he used for septic system placement; underground stormwater detention systems; and the following stormwater management facilities/ structures if designed in full accordance with the specifications provided in the most current edition of the Georgia Stormwater Management Manual; vegetated channels, overland flow filtration/groundwater recharge zone, enhanced swales, filter strips, and grass channels, Septic systems and stormwater structures shall be exclusive of each other and the minimum distance of separation between wastewater and stormwater structures shall be established by the Environmental Health Department and the Environmental Management Department. Utilities (including underground stormwater piping) and multi-use path connections may be located anywhere within the landscape area. b. Side Yard Landscape Area: Ten feet in depth along the side property lines unless adjacent to a residential district where buffer requirements will apply. (6) Use of existing structure. When property containing legal conforming or legal nonconforming structures, under the current zoning, is rezoned to a nonresidential zoning district the dimensional requirements shall be reduced to the extent of, but only at the location of, any encroachment by the structures and said structures shall be considered legal nonconforming structures. (7) Lighting and shielding standards. Lighting shall be placed in a manner to direct light away from any adjacent roadways or nearby residential areas. (8) Special locational and spatial requirements. a. No more than 50 percent of the required parking can be located in the front yard along a State Route as established by the front building line of any structure located on the site. Sites with existing parking are exempt. b. No outside storage allowed. c. All rooftop heating, ventilation, and air conditioning equipment and satellite/communications equipment shall be visually screened from adjacent roads and property zoned residential or A-R. The screen shall extend to the full height of the objects being screened. ## History (Code 1992, § 20-7-6; Ord. No. 2012-09, § 5, 5-24-2012; Ord. No. 2016-15, § 5, 7-28-2016)