In zoning districts where permitted, fee-simple townhouses shall meet the following requirements: (a) Lot Frontage and Lot Width. Each platted lot shall have a minimum of twenty (20) feet of frontage on a public street or private road that meets public street standards, and each lot shall have a minimum lot width of unit width plus side setback on end units. (b) Unit Width. Each rear entry garage townhome shall have a minimum width of 24 feet and each front entry garage townhome shall have a minimum width of 26 feet. (c) Lot Size. The minimum size of a lot for each fee-simple townhouse lot (i.e., the extent of land owned by the owner of the unit) shall be 3,500 square feet. (d) Front Building Setbacks. There shall be a minimum twenty-five (25) foot front setback from any perimeter boundary of the feesimple townhouse subdivision and a 30-foot front setback from any public or private street exterior to or within the subdivision. (e) Side Setbacks and Zero Lot Line. Zero lot line between units within the same building shall be permitted, subject to applicable fire and building codes. Ten (10) foot side setbacks for end units adjacent to internal streets and thirty (30) feet from any public or private street exterior to the subdivision. (f) Rear Setbacks. There shall be a minimum twenty (20) foot rear setback from townhouse lot boundaries for all buildings and structures, except when the rear property line abuts an alley, in which case a minimum distance of twenty-five (25) feet from garage to sidewalk or back of curb for rear entry garages. (g) Building Separation. There shall be a minimum building separation of twenty (20) feet between townhouse buildings. (h) Building Unit Offsets. To avoid a monotonous appearance, for any given building, no more than six (6) units may have common walls. Any building containing more than three (3) units with common walls must have the front facade, rear facade, and the roof of each attached unit distinct from the other through separation, staggering, or offsets in design. A minimum of two (2) exterior colors shall be used on buildings containing up to four (4) units, and a minimum of three (3) exterior colors shall be used on buildings containing five (5) or six (6) units; however, when all exteriors are unpainted brick, they shall not be required to vary in color. See also Section 12.6.(k)1. (i) Rear Access. Townhouse developments shall be designed to provide proper access to all dwelling units for firefighting purposes, as may be determined by applicable codes. Rear access, if required for firefighting purposes or by Subsection (n) below, shall be accomplished by alleys. (j) Parking. Two enclosed parking spaces minimum per unit shall be provided. (k) Subdivision Plat Approval. Each townhouse development or phase thereof shall require preliminary and final subdivision plat approval in accordance the City of Flowery Branch Subdivision and Land Development Ordinance. (l) Wall Finishes. 1. Exterior wall finish materials (excluding foundations, trim, windows and doors) shall be limited to: real brick (full-depth or thin brick), unpainted natural stone, unpainted cast stone, true three-coat cement stucco, natural wood or cementitious siding including lap siding and board and batten; and wood or cementitious shakes and shingles. A horizontal accent strip (i.e., band board or belly board/band) shall be used when there is a change in material. Each dwelling unit is limited to two of the allowed wall finishes listed in this subsection and one paint color. Adjoining or adjacent units shall not be the same exterior color. The following are illustrative examples of wall finishes that DO NOT meet the requirements of this section: 2. All street-facing facades shall meet the following requirements: a. Each applicable facade shall have: a minimum of 5% transparency (defined as the minimum percentage of windows and doors that must cover a ground or upper story facade) of the total wall area; and, a maximum of 20 feet of blank wall area (defined as the portion of the exterior facade of a building that does not include windows or doors; pilasters or other articulation greater than 12 inches in depth; or a substantial change in material) in either a vertical or horizontal direction. b. False windows may count toward the transparency requirement where they are similar in size, shape, and materials to other windows on that building and consist of trim with closed shutters that have the appearance of a shuttered window or windows. A single louvered panel with trim may also count toward this requirement. False windows shall not be allowed to count toward this requirement unless shutters adja-cent to a true window or windows are also provided on another exterior wall. (m) Foundation Walls. Exposed foundation walls must be faced in real brick or real stone to the level of the first finished floor when there is a basement or at least 24 inches above grade for the entire perimeter wall when the building has a slab on grade. Faux brick or stone foundation panels are prohibited. The following are illustrative examples of foundation walls that DO NOT meet the requirements of this section: (n) Roof Materials. Pitched roofs shall be finished in either architectural shingles or standing seam metal roofs. (o) Garage Placement and Materials. 1. Where townhouse developments abut public streets, lots fronting onto these streets shall address garage placement as follows: the front facade of the townhouse shall face the public street, and garages shall be rear-loaded. 2. Where front-loaded garages are allowed, garage doors shall be carriagestyle (both the door style/paneling as well as the hardware) and may either: a. Recess at least one foot behind the front wall plane of the dwelling unit and the front entrance. When the garage door is recessed less than one foot, there shall be required a garage eyebrow treatment (trellis, pergola, roof, or a second-story architectural feature) that extends at least one foot beyond the garage face. b. Project beyond the front wall plane and the front entrance upon providing a garage eyebrow treatment (trellis, pergola, roof, or second-story architectural feature) that extends at least one foot beyond the garage face, as well as decorative lighting that is mounted above or to the sides of the garage door. 3. All front-loaded garages shall be finished in real brick or real stone. The finish shall cover the entire facade of a projecting garage. When garage doors are recessed in accordance with Section (o)2.a. above, the facade of the ground floor shall be finished in the required material(s). 4. Single-story detached garages that meet the requirements of subsections (k), (l) and (m) above and are placed to the rear of the building(s) are allowed in lieu of attached garages. The following are illustrative examples of garage treatments that DO NOT meet the requirements of this section: Brick or stone is only partially used or is not used at all as the required exterior finish, and carriage-style garage doors are not used. In addition, required elements over the projecting garages (left and middle examples) are missing. (p) Private Open Space. Private, usable open space, such as balconies, patios, decks, etc. shall be provided contiguous to each dwelling unit. The area of such open space for each dwelling unit shall not be less than 10% of the floor area of the unit served. 1. Each dwelling unit with a rear-loaded garage shall provide a usable covered porch that runs the entire width of the front facade. The porch shall be at least 6 feet deep (not including steps, if applicable). 2. Rear patios, decks and porches shall be covered with a roof, pergola, or projecting architectural feature that is designed with materials to match the facade and/or trim of the building. (q) Residential Driveway Length. Townhouses are required to have a minimum driveway length of twenty-five (25) feet as measured from the back of sidewalk or back of curb, as applicable. (Ord. No. 657, § 1(Exh. A), 12-16-2021; Ord. No. 733, § 1(Exh. A), 3-20-2025; Ord. No. 746, § 1, 8-7-2025)