Illuminance levels for outdoor lighting fixtures shall comply with the standards in Table 23.1, measured at three feet above the ground or finished grade.
Table 23.1 Outdoor Lighting Intensity Regulations At Property Lines Including Rights-of-Way Minimum Footcandles Maximum Footcandles At property line abutting a residential use None 0.5 At property line abutting an office or institutional use None 1.0 At property line abutting a commercial or industrial use None 1.5 Off-Street Parking Lots
Minimum Footcandles Average Footcandles Maximum Footcandles Residential areas 0.5 2 4 Office-professional areas 1.0 3 6 Commercial areas 2.0 6 12 Industrial areas 1.0 4 8" _________________________________________________________________________________________________ (Ord. No. 348-13, § 10, 8-18-2011)