(a) Prohibition. New construction of principal buildings, including manufactured homes shall not be allowed within the limits of the future-conditions floodplain unless all requirements of this Article (Sections 32.25, 32.26, 32.27, 32.28 and 32.29) have been met. (b) Elevation of Lowest Floor. If all of the requirements of this Article (Sections 32.25, 32.26, 32.27, 32.28 and 32.29) have been met, all new construction shall have the lowest floor, including basement, elevated no lower than three (3) feet above the base flood elevation or one (1) foot above the futureconditions flood elevation, whichever is higher. (c) Unimpeded Movement of Floodwaters. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to equalize the hydrologic flood forces on exterior walls and to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of Section 32.32(a), (b), and (c) of this Article.